DW-54/30 Nitrogen Compressor – Ultra-High-Pressure Oil-Free N2 Booster for 3.00 MPa Demanding Process Applications

説明

DW-54/30 Nitrogen Compressor – Ultra-High-Pressure Oil-Free N2 Booster for 3.00 MPa Demanding Process Applications

Engineered to deliver 50 m³/min at 3.00 MPa discharge pressure, the DW-54/30 is a two-stage, four-row oil-free piston nitrogen compressor designed for the most demanding high-pressure industrial gas applications. Four-stage compression, massive flow capacity, and zero oil contamination for critical petrochemical, gas liquefaction, and pipeline injection operations.

DW-54/30 nitrogen compressor ultra high pressure oil-free industrial unit

製品概要

DW-54/30 nitrogen compressor stands at the apex of our oil-free piston compressor portfolio, representing the culmination of advanced engineering for ultra-high-pressure industrial gas applications. With a formidable capacity of 50 m³/min そして並外れた 3.00 MPaの吐出圧力, this unit addresses the most demanding nitrogen compression requirements found in large-scale petrochemical operations, gas liquefaction plants, and high-pressure pipeline injection systems.

What distinguishes the DW-54/30 from all other models in our lineup is its four-stage, two-row (二列四级) compression architecture. This multi-stage design is absolutely essential for achieving the 3.00 MPa discharge pressure while maintaining thermodynamic efficiency and preserving the integrity of the oil-free PTFE sealing system. Each of the four compression stages is equipped with an independent intercooler, creating a cascade of progressively higher pressure cylinders that divide the enormous overall pressure ratio into manageable segments. Without this staged approach, the discharge temperatures would exceed the safe operating limits of oil-free sealing materials, making four-stage compression a fundamental engineering requirement rather than an optional feature.

The compressor maintains our commitment to fully oil-free compression through advanced PTFE composite piston rings and rider bands that operate without hydrocarbon lubricants. At 3.00 MPa, the risk of oil contamination is magnified exponentially compared to low-pressure applications, as any oil vapor present would be concentrated to dangerous levels. The DW-54/30’s native oil-free design achieves ISO 8573-1 クラス0認証 without any downstream purification equipment, making it the only viable choice for ultra-high-pressure applications where nitrogen purity is non-negotiable.

DW-54/30 nitrogen compressor four stage high pressure piston assembly

Technical Specifications – DW-54/30

パラメータ 価値 ユニット
モデル DW-54/30
パターン 二段四列(二列四级)
容量 50 m³/分
吐出圧力 3.00 MPa
コンプレッサーのサイズ(長さ×幅×高さ) 5456 × 3518 × 2535 mm
重さ 13.00 t
630 kW
電圧 6,000円または10,000円 V
ガス媒体 窒素(N₂)
潤滑 オイルフリー

* すべての仕様は標準基準条件(ISO 1217、附属書C)に基づいています。実際の性能は、設置場所の標高、周囲温度、および吸気条件によって異なる場合があります。

主な特長とエンジニアリング上の利点

1. Four-Stage Compression for Ultra-High Pressure

The DW-54/30 employs a four-stage, two-row compression architecture that is unique within our product portfolio and essential for achieving 3.00 MPa discharge pressure. The overall pressure ratio of approximately 30:1 to 60:1 (depending on inlet conditions) is divided across four sequentially arranged compression cylinders, with inter-stage cooling after each stage. This cascade approach limits the pressure ratio per stage to approximately 2.5:1 to 3.5:1, keeping discharge temperatures below 160°C and preserving the dimensional stability of the PTFE sealing elements. Without four-stage compression, the discharge temperature would exceed 250°C, far beyond the safe limit of oil-free materials. Each stage features progressively smaller cylinder bores to accommodate the reduced gas volume at higher pressures, optimizing volumetric efficiency across the entire pressure range.

2. High-Pressure Oil-Free PTFE Sealing System

The DW-54/30 utilizes an advanced self-lubricating piston ring and rider band system manufactured from ultra-high-performance PTFE composites specifically formulated for 3.00 MPa service. These rings are reinforced with high-aspect-ratio glass fibers, bronze particulates, and proprietary additives that enhance creep resistance and dimensional stability under extreme pressure. The material achieves a coefficient of friction below 0.05 without any hydrocarbon lubrication, ensuring the nitrogen stream remains completely free of oil contamination. At 3.00 MPa, even trace oil contamination would be concentrated to levels that would render the nitrogen unusable for most industrial applications, making the oil-free design an absolute requirement rather than a preference.

3. Heavy-Duty Reinforced Frame for Extreme Mechanical Loads

メインフレームは鋳造されています GG30 グレー鋳鉄 (equivalent to ASTM A48 Class 35B) with substantially reinforced wall sections, additional ribbing, and integral cooling water passages. The four-cylinder arrangement generates significant peak gas forces at 3.00 MPa, requiring frame stiffness far exceeding that of lower-pressure models. The two-row opposed-cylinder layout provides partial force cancellation, but the sheer magnitude of the gas loads at ultra-high pressure necessitates a foundation mass of 最低20トン to ensure stable operation. The crankshaft is forged from 34CrNiMo6 alloy steel (higher grade than standard 42CrMo4) and undergoes precision grinding and dynamic balancing to ISO 1940 G1.0 standards to minimize vibration at the high operating loads.

4. Medium-Voltage Motor Drive for High-Power Operation

The DW-54/30 is driven by a 630 kW medium-voltage induction motor available in either 6kV or 10kV configurations, conforming to IEC 60034-1 efficiency class IE3. At 630 kW, low-voltage 380V operation would require impractical cable sizes and switchgear ratings, making medium-voltage drive mandatory. The motor is directly coupled to the compressor crankshaft through a heavy-duty flexible disc coupling rated for the torque and misalignment requirements of high-pressure reciprocating service. Direct medium-voltage integration reduces electrical losses, minimizes cable infrastructure, and ensures compatibility with standard industrial power distribution in large process plants.

DW-54/30 nitrogen compressor general assembly four stage heavy duty design

アプリケーションシナリオ

Ultra-High-Pressure Pipeline Nitrogen Injection

In long-distance nitrogen pipeline systems and high-pressure gas distribution networks, the DW-54/30 serves as the primary high-pressure booster station. Its 3.00 MPa discharge pressure is sufficient to overcome pipeline friction losses over distances exceeding 50 km and to maintain adequate pressure at the most remote consumers. The 50 m³/min capacity can supply multiple high-pressure tapping points simultaneously, making it suitable for centralized nitrogen supply to large industrial complexes. The oil-free design is critical in pipeline applications because any contamination would propagate throughout the entire distribution network, affecting all downstream consumers.

DW-54/30 nitrogen compressor ultra high pressure pipeline injection

Gas Liquefaction Plant High-Pressure Booster

In nitrogen liquefaction facilities, the DW-54/30 nitrogen booster compresses nitrogen from the liquefier cold end or storage vaporizer to the high pressure required for liquefaction cycle efficiency. The 3.00 MPa discharge pressure is typical for Claude-cycle liquefiers and other high-pressure nitrogen liquefaction processes where elevated pressure is essential for achieving cryogenic temperatures through expansion. The massive 50 m³/min capacity matches the throughput of medium-to-large-scale liquefaction plants producing 50–100 tons per day of liquid nitrogen. The oil-free design prevents contamination of the liquefier heat exchangers, which would severely degrade thermal performance and require costly defrosting and cleaning.

Petrochemical Emergency Nitrogen Injection & Purging

In petrochemical and refinery operations, the DW-54/30 provides ultra-high-pressure nitrogen for emergency reactor inerting, catalyst bed preservation, high-pressure vessel purging, and safety system nitrogen supply. The 3.00 MPa discharge pressure is sufficient to inject nitrogen into virtually any process vessel or reactor system, including those operating at elevated pressures. The continuous-duty rating ensures that emergency nitrogen is available instantaneously without the warm-up delays associated with starting standby compressors. The oil-free certification is mandatory for petrochemical applications where nitrogen contacts catalyst beds, enters process streams, or is used for product-quality-sensitive operations.

DW-54/30 nitrogen compressor petrochemical emergency injection purging

Underground Gas Storage & Cavern Sealing

Underground gas storage facilities, including salt caverns and depleted reservoirs, require high-pressure nitrogen for cushion gas injection, cavern sealing, and pressure maintenance during gas withdrawal cycles. The DW-54/30’s 3.00 MPa discharge pressure is adequate for injecting nitrogen into storage caverns operating at pressures up to 2.50 MPa, maintaining the structural integrity of the cavern walls and preventing groundwater ingress. The 50 m³/min capacity allows rapid filling of large storage volumes, reducing the time required for cavern commissioning and maintenance operations. The oil-free design prevents contamination of the stored gas, which is critical when the stored nitrogen is later withdrawn for high-purity applications.

材料と構造

The DW-54/30 is constructed from premium materials selected for ultra-high-pressure nitrogen compatibility, extreme mechanical loading, and extended operational life:

成分 材料 仕様
Frame ねずみ鋳鉄 GG30 / HT300, heavily reinforced with ribbing
クランクシャフト 鍛造合金鋼 34CrNiMo6, Q&T, ISO 1940 G1.0 balanced
シリンダーブロック(全ステージ) ねずみ鋳鉄 GG30 / HT300, progressive wall thickening for HP stages
ピストンリング PTFE-ガラス-青銅複合材 Ultra-high-pressure rated, 185°C max, creep-resistant
ライダーバンド PTFE複合材 High-load guidance, anti-scuffing, wear rate <0.03 mm/1000h
バルブプレート ステンレス鋼 SS316, heavy-duty concentric ring spring design
Intercoolers (1–3) 炭素鋼製シェル/SS316製チューブ ASME VIII Div.1、1.5倍の耐圧試験、30分間保持
アフタークーラー 炭素鋼製シェル/SS316製チューブ 高圧フィン付きチューブ、32℃冷却水
高圧配管 シームレスステンレス鋼 SS316, ANSI Class 900 flanges, 100% RT
ベースフレーム 重構造用鋼材 Welded box-section, vibration-damped mounting

すべての圧力支持部品は、以下の基準に厳密に従って設計および製造されています。 ASME BPVC セクション VIII ディビジョン 1 または中国のGB 150規格に準拠しています。すべての溶接継手はASME Section V、Article 2に従って100%放射線検査(RT)を受け、完成した圧力容器はすべて、最大許容使用圧力(MAWP)の1.5倍の圧力で最低30分間の静水圧試験を受けます。高圧配管システムは、3.00 MPaの運転圧力で漏れのない完全性を確保するために、ANSI Class 900フランジ接続を備えたシームレスSS316で製造されています。

DW-54/30 nitrogen compressor factory heavy duty machining and assembly

設置およびメンテナンスに関するガイドライン

基礎および構造要件

The DW-54/30 has a dry weight of 13.00 tonnes and a center of gravity approximately 1,000 mm above the baseplate. The four-cylinder arrangement generates substantial peak gas forces at 3.00 MPa, requiring a 最低20トンの鉄筋コンクリート慣性ブロック. The block must be mounted on heavy-duty elastomeric vibration isolators (natural frequency 5–7 Hz) or spring isolators to prevent vibration transmission to adjacent structures. The foundation must be designed by a qualified structural engineer to support the dynamic loads, which include both the reciprocating inertia forces and the gas pressure pulsations. Minimum clearance requirements: 2.0 m on the non-drive side for valve access, 1.5 m on the drive side for motor maintenance, and 2.5 m overhead for crane access during major overhauls.

冷却水システムの設計

冷却水の需要は約 80 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit supplies the cylinder jackets and three intercoolers in parallel branches, with the aftercooler on a separate circuit. Given the four-stage compression and high pressure ratio, the intercoolers are absolutely critical for thermal management and must receive priority cooling water flow. Water quality specifications: pH 6.5–8.5, total dissolved solids < 400 mg/L, chloride content < 30 mg/L (to prevent SS316 tube corrosion in the high-pressure coolers), suspended solids < 20 mg/L, and total hardness < 250 mg/L as CaCO₃. A closed-loop cooling tower with side-stream filtration and automated chemical treatment is mandatory for reliable operation.

予防保守スケジュール

間隔 サービス項目 対応が必要
毎日 運用検査 Check vibration, abnormal noise, cooling water flow, all stage pressures and temperatures
200時間 バルブプレート検査(高圧段階) Inspect 3rd and 4th stage valves for carbon deposits, spring fatigue, cracking
500時間 Valve Plate Inspection (All stages) Inspect all stage valves, replace any showing wear or leakage
1,000時間 ピストンリング摩耗評価 Measure ring groove clearance on all stages; replace if > 0.18 mm
3,000時間 中間オーバーホール Replace all piston rings, rider bands, and valve plate assemblies across all stages
6,000時間 大規模な改修 クランクシャフトジャーナルを点検し、すべてのベアリングクリアランスを測定し、0.06 mmを超える場合はメインベアリングを交換する。

The oil-free design of the DW-54/30 eliminates the extensive maintenance requirements of lubricated alternatives. There are no oil changes, no oil analysis, no filter replacements, and no separator cartridge changes. The primary consumable wear items are the PTFE製ピストンリングおよびライダーバンド, which typically achieve 3,000–5,000 hours of service life under clean nitrogen conditions. However, the high-pressure valve plates (particularly stages 3 and 4) may require more frequent inspection due to the extreme mechanical stress at 3.00 MPa. The four-stage design actually extends the life of individual components by reducing the stress per stage compared to a two-stage design operating at the same overall pressure ratio.

DW-54/30 nitrogen compressor workshop assembly and precision inspection

法令遵守および安全認証

The DW-54/30 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:

圧力機器
ASME BPVC セクション VIII Div.1、GB 150-2011、PED 2014/68/EU モジュール A
電気および機械の安全
IEC 60034-1(IE3効率)、IEC 60204-1、ISO 12100機械安全規格
オイルフリー認証
ISO 8573-1 クラス0(油分含有量)、TÜVラインランドによる独立試験済み
品質と環境
ISO 9001:2015、ISO 14001:2015
⚠️ 重大な安全上の注意 – 超高圧運転

Nitrogen is classified as a simple asphyxiant gas. At 3.00 MPa discharge pressure, the risk of catastrophic gas release and rapid oxygen displacement is extremely high. All DW-54/30 installations must incorporate: (1) Continuous oxygen deficiency monitoring with multiple sensors in the compressor room; (2) High-pressure discharge piping with pressure relief valves rated at 110% of MAWP and rupture discs as secondary protection; (3) Automatic isolation valves on suction and discharge that close on emergency shutdown; (4) Ventilation systems maintaining ambient oxygen above 19.5% per OSHA 29 CFR 1910.146; (5) Emergency shutdown interlocks at 19.5% O₂ (alarm) and 18.0% O₂ (hard shutdown); (6) Personnel trained in ultra-high-pressure gas safety protocols; (7) Restricted access to the compressor area with authorized-entry procedures. All high-pressure piping must be designed, fabricated, and inspected by qualified pressure piping specialists.

DW-54/30 nitrogen compressor ISO certification and compliance documentation

パフォーマンスと効率の分析

The DW-54/30 achieves a specific power consumption of approximately 12.60 kW per m³/min of nitrogen delivered at 3.00 MPa discharge pressure. This specific power figure reflects the thermodynamic reality of ultra-high-pressure compression, where the work required increases dramatically with pressure ratio. However, the four-stage design with inter-stage cooling maintains this figure within a competitive range for oil-free compressors in the ultra-high-pressure segment. For comparison, oil-lubricated reciprocating compressors in similar applications typically consume 13.5–15.0 kW/m³/min, while diaphragm compressors (often selected for oil-free ultra-high-pressure service) may exceed 18 kW/m³/min and deliver only a fraction of the capacity.

Over an 8,000-hour annual operating schedule, the DW-54/30’s four-stage efficiency advantage versus less efficient alternatives yields approximately 360,000–720,000 kWh of annual energy savings. At $0.08/kWh, this represents $28,800–$57,600 in direct electricity cost reduction per year. However, the primary economic justification for the DW-54/30 is typically the elimination of oil-related consumables and the avoidance of downstream purification equipment that would be mandatory with lubricated alternatives. The 超高圧窒素圧縮装置の総所有コスト is reduced by an estimated 25–35% over a 10-year operational life when oil-free operation is compared to lubricated systems with full downstream purification.

At 3.00 MPa, the concentration effect of oil contamination is severe. A lubricated compressor producing nitrogen with 1.0 mg/m³ oil content at atmospheric pressure would deliver nitrogen with approximately 30 mg/m³ oil content at 3.00 MPa due to the compression and condensation effects. This level of contamination would be catastrophic for virtually all industrial applications, making the DW-54/30’s native oil-free design not merely preferable but absolutely essential for ultra-high-pressure service.

カスタマイズおよびOEM対応

We offer comprehensive customization options to adapt the DW-54/30 to specific site conditions, integration requirements, and end-user specifications:

  • スキッドマウント型ターンキーパッケージ: The compressor, motor, all four intercoolers, aftercooler, high-pressure discharge piping, instrumentation, and control panel are pre-assembled on a heavy-duty structural steel skid with integrated lifting lugs and anchor bolt templates. Factory pre-testing of all systems reduces commissioning time and risk.
  • 危険区域構成: ATEX Zone 2 and IECEx compliant motor and electrical enclosures for petrochemical installations. Integrated gas detection, automatic ventilation interlocks, and explosion-proof instrumentation can be incorporated into the control system.
  • 高度なプロセス制御: Siemens S7-1500 or Allen-Bradley ControlLogix PLC with 15-inch HMI touchscreen, remote monitoring via Modbus TCP/IP or OPC-UA, and seamless DCS/SCADA integration. Automatic stage sequencing, load/unload control, and variable frequency drive (VFD) compatibility optimize efficiency and reduce mechanical wear.
  • 環境保護: C5-M marine-grade coating systems for coastal installations; tropicalized electrical components for 55°C ambient; and IP54-rated acoustic enclosures with special high-pressure noise attenuation reducing emission from 88 dB(A) to 75 dB(A) at 1 meter.
  • OEMおよびプライベートブランド: Custom paint colors, branded nameplates, and localized documentation packages for gas equipment distributors and system integrators serving global markets.

カスタム構成は以下から入手可能です 最小注文数量:1個. Engineering review and proposal generation typically require 7–10 business days due to the complexity of the four-stage system. Standard delivery time is 16–20 weeks; repeat orders are delivered in 12–14 weeks from order confirmation.

DW-54/30 nitrogen compressor custom skid mounted ultra high pressure package

Case Study: LNG Plant Nitrogen Liquefaction Booster

クライアント: A mid-scale LNG liquefaction facility in Malaysia producing 500,000 tons per year

チャレンジ: The facility’s nitrogen liquefaction unit was using two oil-lubricated compressors in series to achieve the 2.80 MPa required for the Claude-cycle liquefier. The oil contamination from the compressors was progressively fouling the liquefier’s aluminum plate-fin heat exchangers, reducing thermal efficiency by 15% over 18 months and requiring expensive defrosting and cleaning cycles every 6 months. The two-compressor arrangement also had poor reliability, with unplanned outages causing LNG production losses of $50,000 per day.

解決: 私たちは供給しました DW-54/30 oil-free nitrogen compressor as a single-unit replacement for the two existing compressors, configured on a custom skid with all four intercoolers, aftercooler, and a Siemens S7-1500 PLC control panel with full SCADA integration. The 3.00 MPa discharge pressure exceeded the liquefier’s requirement, providing a pressure margin that improved cycle efficiency. The oil-free design eliminated heat exchanger fouling entirely. A 10 m³ surge vessel was installed upstream to buffer demand fluctuations from the liquefier.

36か月後の定量的な結果:

  • Heat exchanger fouling: 完全に排除された, restoring thermal efficiency to design levels
  • Defrosting cycles: 脱落, saving $120,000/year in maintenance and production downtime
  • Unplanned outages: イベントゼロ in 36 months versus 8 events with the previous two-compressor system
  • LNG production losses avoided: $400,000 over 36 months
  • エネルギー消費量: Improved by 8.2% versus the replaced system, saving $32,000/year
  • Payback period: 2.5 years including avoided production losses and maintenance savings

“The DW-54/30 has been the single most impactful equipment upgrade in our plant’s history. The elimination of oil contamination has restored our liquefier performance, and the reliability improvement has been remarkable. We haven’t had a single unplanned outage in three years.” — Chief Operating Officer, LNG Facility

DW-54/30 nitrogen compressor LNG plant liquefaction installation case study

よくある質問と選択ガイド

What is the expected service life of the DW-54/30 under ultra-high-pressure conditions?

The DW-54/30 is engineered for a minimum design life of 12 years (approximately 100,000 operating hours) in clean nitrogen service at 3.00 MPa. The reinforced GG30 frame and forged 34CrNiMo6 crankshaft are rated for the full design life. PTFE piston rings and rider bands are the primary wear components, with replacement intervals of 3,000–5,000 hours. High-pressure valve plates (stages 3 and 4) typically require inspection at 1,500–2,500 hours and replacement at 2,500–4,000 hours due to the extreme mechanical stress at 3.00 MPa.

Why does the DW-54/30 require four stages when other compressors use only two?

The four-stage design is a thermodynamic necessity, not an optional feature. To achieve 3.00 MPa from typical inlet pressures (0.05–0.10 MPa), the overall pressure ratio is approximately 30:1 to 60:1. A two-stage compressor would require each stage to operate at a pressure ratio of 5:1 to 8:1, resulting in discharge temperatures exceeding 250°C—far beyond the safe limit of PTFE oil-free sealing materials (which degrade above 185°C). The four-stage design divides the pressure ratio into four segments of approximately 2.5:1 to 3.5:1 each, keeping all stage discharge temperatures below 160°C and ensuring reliable PTFE operation. Additionally, the four-stage approach improves overall thermodynamic efficiency by reducing the mean effective temperature of compression.

Is the DW-54/30 suitable for outdoor installation?

The standard DW-54/30 is designed for 屋内設置 in a dedicated compressor house with adequate ventilation and crane access. Due to its 13-tonne weight and substantial foundation requirements, outdoor installation is possible but requires a custom-engineered weatherproof shelter with integrated HVAC, crane access, and noise attenuation. The acoustic enclosure option for outdoor use is a specialized design that reduces noise emission from 88 dB(A) to 75 dB(A) at 1 meter. Outdoor installations require careful consideration of thermal management, as ambient temperature extremes affect the performance of the four intercoolers.

How does the DW-54/30 compare to oil-lubricated alternatives for ultra-high-pressure nitrogen?

Oil-lubricated reciprocating compressors can achieve 3.00 MPa but introduce unacceptable oil contamination risk at this pressure level. At 3.00 MPa, the concentration of oil vapor is approximately 30 times higher than at atmospheric pressure, making downstream oil removal virtually impossible. The DW-54/30 achieves ISO 8573-1クラス0認証をネイティブに取得 without any downstream filtration. Compared to diaphragm compressors (the primary oil-free alternative), the DW-54/30 offers 5–10 times the capacity at half the specific power consumption and one-third the capital cost. For a comprehensive TCO comparison, see our 窒素圧縮機のROI分析.

When should I avoid selecting the DW-54/30?

The DW-54/30 is NOT recommended for: (1) Discharge pressures below 2.00 MPa—the four-stage design is unnecessarily complex and expensive for lower pressures; consider our DW-36/30 or LW-52/8 models instead; (2) Capacity requirements below 20 m³/min—smaller models in the DW or ZW series offer better part-load efficiency; (3) Applications without adequate foundation capacity—the 20-tonne minimum foundation requirement may be impractical for some existing facilities; (4) Installations without reliable medium-voltage electrical supply—the 630 kW motor requires 6kV or 10kV power; (5) Continuous flow modulation below 50% of rated capacity—the four-stage compressor is optimized for steady-state operation; highly variable demand may require a dual-unit arrangement.

関連製品およびソリューション

DW-36/30 High-Pressure Nitrogen Compressor

A smaller-capacity four-stage oil-free compressor delivering 36 m³/min at 3.00 MPa. Ideal for applications where the full 50 m³/min of the DW-54/30 is not required, offering lower capital cost and reduced foundation requirements.

Explore DW-36/30 →

ZWシリーズ 多段式オイルフリーコンプレッサー

酸素、窒素、水素、および特殊ガス用の縦型多段式オイルフリーコンプレッサー。最大吐出圧力は9.00MPaで、超高圧ガス充填や特殊化学プロセス用途に対応します。

ZWシリーズを探索する →

LWシリーズ大容量窒素コンプレッサー

High-flow oil-free piston compressors (20–130 m³/min) for cryogenic ASU backup, VPSA boosting, and industrial pipeline distribution. Discharge pressures from 0.30 to 0.80 MPa for medium-pressure applications.

LWシリーズを探索する →

当社の包括的な概要については、 工業用窒素圧縮機 オイルフリー酸素圧縮機、水素圧縮機、二酸化炭素圧縮機、および特注設計の特殊ガスソリューションを含む製品ポートフォリオの詳細については、当社のアプリケーションエンジニアリングチームにお問い合わせいただくか、オンライン製品カタログをご覧ください。

Ready to Deploy Ultra-High-Pressure Nitrogen Compression?

Our senior application engineers are available to evaluate your ultra-high-pressure nitrogen requirements, including flow demands, suction conditions, discharge pressure targets, foundation constraints, and integration with existing process systems. We provide comprehensive technical proposals, foundation design guidance, piping and instrumentation diagrams (P&IDs), and detailed total cost of ownership (TCO) analyses within 5–7 business days of receiving your inquiry.

メールアドレス: [email protected] 24時間以内に返信いたします