Engineered to deliver 10 m³/min at 2.00 MPa discharge pressure, the LW-10/20 is a two-stage, two-row oil-free piston nitrogen compressor purpose-built for high-pressure nitrogen injection, gas cylinder filling, and demanding petrochemical process applications. Zero oil contamination, robust construction, and optimized for continuous-duty operation at elevated pressure.

LW-10/20 nitrogen compressor high pressure oil-free industrial unit

製品概要

LW-10/20 nitrogen compressor occupies a specialized position within our oil-free piston compressor portfolio, engineered for applications where elevated discharge pressure is the primary requirement rather than massive flow capacity. With a rated capacity of 10 m³/分 そして並外れた 2.00 MPa discharge pressure, this unit bridges the gap between medium-pressure nitrogen distribution and high-pressure process applications that demand significantly elevated gas pressure.

What distinguishes the LW-10/20 from conventional alternatives is its fully oil-free compression mechanism utilizing self-lubricating PTFE composite piston rings and rider bands. This design philosophy eliminates any possibility of hydrocarbon contamination in the nitrogen product stream, making the unit immediately suitable for high-purity nitrogen cylinder filling, pharmaceutical process gas supply, and electronics-grade nitrogen applications without requiring additional downstream purification equipment. The oil-free certification is particularly critical for high-pressure applications where oil contamination would be concentrated and more difficult to remove.

コンプレッサーは 二段二列 (二列二级) configuration that is essential for managing the substantial pressure ratio required to achieve 2.00 MPa discharge pressure from typical inlet conditions. Each stage is independently cooled through a dedicated intercooler, ensuring gas temperatures remain within safe operating limits and preserving the dimensional stability of the PTFE sealing elements. The robust frame construction and precision-machined crankshaft assembly are rated for a minimum service life of 12万時間 標準的な保守手順に従って。

LW-10/20 nitrogen compressor high pressure two stage piston design

Technical Specifications – LW-10/20

パラメータ 価値 ユニット
モデル LW-10/20
パターン 二段二列 (二列二级)
容量 10 m³/分
吐出圧力 2.00 MPa
コンプレッサーのサイズ(長さ×幅×高さ) 2632 × 1550 × 2332 mm
重さ 3.00 t
110 kW
電圧 380 / 6k or 10k V
ガス媒体 窒素(N₂)
潤滑 オイルフリー

* すべての仕様は標準基準条件(ISO 1217、附属書C)に基づいています。実際の性能は、設置場所の標高、周囲温度、および吸気条件によって異なる場合があります。

主な特長とエンジニアリング上の利点

1. High-Pressure Oil-Free PTFE Sealing Technology

The LW-10/20 utilizes a proprietary 自己潤滑ピストンリングおよびライダーバンドアセンブリ manufactured from high-performance PTFE composites specifically formulated for high-pressure service. These rings are reinforced with glass fiber and bronze particulates to achieve a coefficient of friction below 0.06 without any external hydrocarbon lubrication. At 2.00 MPa discharge pressure, the risk of oil vapor carryover is magnified compared to lower-pressure applications, making the oil-free design not merely advantageous but absolutely essential. The PTFE composite formulation is rated for continuous operation at temperatures up to 185°C, ensuring reliable sealing integrity even under the thermal stress of high-pressure compression.

2. Two-Stage Compression for Extreme Pressure Ratios

2段階圧縮アーキテクチャ of the LW-10/20 is thermodynamically essential for achieving the 2.00 MPa discharge pressure target from typical inlet pressures of 0.05–0.10 MPa. The overall pressure ratio of approximately 20:1 to 40:1 is split between a low-pressure cylinder and a high-pressure cylinder, with each stage operating at a manageable pressure ratio. A high-efficiency shell-and-tube intercooler between stages removes the substantial heat of compression, maintaining discharge temperatures below 165°C and preventing thermal degradation of the PTFE sealing elements. Without staged compression, the discharge temperature would exceed the safe operating limit of PTFE materials, making the two-stage design a fundamental requirement for this pressure level.

3. Robust Frame Construction for High-Pressure Loads

メインフレームは鋳造されています GG25 グレー鋳鉄 (equivalent to ASTM A48 Class 30B) with reinforced wall sections and integral cooling water passages. The high-pressure cylinder features thicker wall castings and additional ribbing to withstand the mechanical stresses associated with 2.00 MPa peak pressures. The two-row opposed-cylinder arrangement provides natural first-order force cancellation, reducing unbalanced inertia forces transmitted to the foundation by over 80% compared to single-row designs. This mechanical advantage is particularly valuable for high-pressure compressors where the peak gas forces on the pistons are substantially higher than in low-pressure applications.

4. Flexible Voltage Configuration for Diverse Installations

The LW-10/20 is driven by a 110 kW induction motor available in 380V, 6kV, or 10kV configurations, conforming to IEC 60034-1 efficiency class IE3. The standard 380V configuration is suitable for facilities with existing low-voltage distribution infrastructure, while the 6kV and 10kV options allow direct integration into medium-voltage industrial networks without step-down transformers. This electrical flexibility makes the LW-10/20 adaptable to a wide range of installation environments, from small industrial facilities to large integrated plants with medium-voltage bus systems.

LW-10/20 nitrogen compressor general assembly high pressure design

アプリケーションシナリオ

High-Pressure Nitrogen Cylinder Filling Stations

The LW-10/20 is ideally suited for nitrogen cylinder filling operations where high-pressure gas must be compressed into standard industrial cylinders at 15–20 MPa filling pressure. While the compressor’s 2.00 MPa discharge pressure does not reach cylinder filling pressure directly, it serves as an efficient intermediate booster that significantly reduces the compression ratio required of downstream high-pressure filling compressors. This staged approach improves overall system efficiency and reduces wear on the expensive high-pressure filling equipment. The oil-free design is mandatory for cylinder filling because any oil contamination would be trapped in the cylinders and delivered to end-users, compromising their processes.

LW-10/20 nitrogen compressor high pressure cylinder filling station

Petrochemical High-Pressure Process Nitrogen

In petrochemical and refinery operations, the LW-10/20 provides high-pressure nitrogen for reactor catalyst preservation, emergency nitrogen injection into high-pressure vessels, and pipeline pressure testing. The 2.00 MPa discharge pressure is sufficient to inject nitrogen into process vessels operating at pressures up to 1.6 MPa, maintaining positive inert gas blankets during startup, shutdown, and upset conditions. The LW-10/20 high-pressure nitrogen booster is also used for hydrostatic testing of process piping and pressure vessels, where nitrogen is used as a test medium to avoid water contamination in systems that must remain dry.

Pharmaceutical Process Gas Supply

Pharmaceutical manufacturing facilities require high-purity nitrogen at elevated pressure for sterile filtration, lyophilization (freeze-drying), and aseptic filling operations. The LW-10/20’s oil-free certification ensures compliance with FDA 21 CFR 211.72 (equipment construction requirements) and EU GMP Annex 1 (manufacture of sterile medicinal products). The 2.00 MPa discharge pressure provides adequate head to drive nitrogen through sterile filtration systems, spray dryers, and fluid bed processors that operate at elevated pressures. The 10 m³/min capacity can simultaneously supply multiple pharmaceutical process units within a single manufacturing facility.

LW-10/20 nitrogen compressor pharmaceutical process gas supply

Electronics High-Pressure Nitrogen Purge

Semiconductor fabrication facilities and electronics assembly plants require high-pressure nitrogen for wafer handling system purge, chemical vapor deposition (CVD) chamber cleaning, and high-pressure drying of precision components. The LW-10/20’s 2.00 MPa discharge pressure is sufficient for driving high-velocity nitrogen jets used in precision cleaning applications and for maintaining positive pressure in wafer transport systems. The oil-free design is absolutely critical in semiconductor applications where even sub-ppm oil contamination can cause catastrophic defects in integrated circuit manufacturing.

材料と構造

The LW-10/20 is constructed from premium materials selected for high-pressure nitrogen compatibility, thermal resistance, and extended operational life:

成分 材料 仕様
シリンダーブロック(LP) ねずみ鋳鉄 GG25 / HT250, standard wall thickness
シリンダーブロック(HP) ねずみ鋳鉄 GG25 / HT250, reinforced wall + ribbing
クランクシャフト 鍛造合金鋼 42CrMo4、Q&T、ISO 1940 G2.5バランス
ピストンリング PTFE-ガラス-青銅複合材 High-pressure rated, self-lubricating, 180°C max
ライダーバンド PTFE複合材 Piston guidance, anti-scuffing, wear rate <0.04 mm/1000h
バルブプレート ステンレス鋼 SS316, high-pressure concentric ring design
インタークーラー 炭素鋼製シェル/SS316製チューブ ASME VIII Div.1、1.5倍の耐圧試験、30分間保持
アフタークーラー 炭素鋼製シェル/SS316製チューブ 高圧フィン付きチューブ、32℃冷却水
高圧配管 シームレスステンレス鋼 SS316, ANSI Class 600 flanges

すべての圧力支持部品は、以下の基準に厳密に従って設計および製造されています。 ASME BPVC セクション VIII ディビジョン 1 or Chinese GB 150 standards. Every weld joint undergoes 100% radiographic inspection (RT) per ASME Section V, Article 2, and each completed pressure vessel is subjected to a hydrostatic pressure test at 1.5 times the maximum allowable working pressure (MAWP) for a minimum hold period of 30 minutes. High-pressure piping systems are fabricated from seamless SS316 with ANSI Class 600 flanged connections to ensure leak-tight integrity at 2.00 MPa operating pressure.

LW-10/20 nitrogen compressor factory precision machining and high pressure testing

設置およびメンテナンスに関するガイドライン

基礎および構造要件

The LW-10/20 has a dry weight of 3.00 tonnes and a center of gravity approximately 800 mm above the baseplate. Due to the two-row opposed-cylinder design, unbalanced forces are minimal despite the high-pressure operation, permitting installation on a reinforced concrete inertia block of 5–6 tonnes. The block should be mounted on elastomeric vibration isolators (natural frequency 7–10 Hz). Minimum clearance requirements: 1.2 m on the non-drive side for valve access, 1.0 m on the drive side for motor maintenance, and 1.5 m overhead for crane access during major overhauls. Special attention must be paid to the high-pressure discharge piping, which must be properly supported and anchored to prevent vibration-induced fatigue.

冷却水システムの設計

冷却水の需要は約 18 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit supplies the cylinder jackets, intercooler, and aftercooler in parallel branches. Given the high pressure ratio, the intercooler is particularly critical for thermal management and must receive adequate cooling water flow at all times. Water quality specifications: pH 6.5–8.5, total dissolved solids < 500 mg/L, chloride content < 50 mg/L (to prevent SS316 tube corrosion), suspended solids < 30 mg/L, and total hardness < 300 mg/L as CaCO₃. A closed-loop cooling tower with side-stream filtration is recommended for sites with marginal water quality.

予防保守スケジュール

間隔 サービス項目 対応が必要
毎日 運用検査 Check vibration, abnormal noise, cooling water flow, discharge temperature, pressure
250時間 バルブプレートの点検 吸込弁/吐出弁を取り外し、カーボン堆積物、スプリング疲労、亀裂がないか点検する。
1,000時間 ピストンリング摩耗評価 リング溝のクリアランスを測定し、クリアランスが0.20mmを超える場合はリングを交換してください。
3,000時間 中間オーバーホール ピストンリング、ライダーバンド、バルブプレートアセンブリをすべて交換してください。
6,000時間 大規模な改修 Inspect crankshaft journals, measure main bearing clearances, replace bearings if >0.08 mm

The oil-free design of the LW-10/20 dramatically simplifies maintenance compared to lubricated alternatives. There are no oil changes, no oil analysis, no filter replacements, and no separator cartridge changes. The primary consumable wear items are the PTFE製ピストンリングおよびライダーバンド, which typically achieve 3,000–5,000 hours of service life under clean nitrogen conditions at high pressure. The high-pressure valve plates may require more frequent inspection than low-pressure equivalents due to the increased mechanical stress, but the overall maintenance burden remains significantly lower than oil-lubricated systems.

LW-10/20 nitrogen compressor workshop assembly and quality inspection

法令遵守および安全認証

The LW-10/20 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:

圧力機器指令
ASME BPVC セクション VIII Div.1、GB 150-2011、PED 2014/68/EU モジュール A
電気および機械の安全
IEC 60034-1(IE3効率)、IEC 60204-1、ISO 12100機械安全規格
オイルフリーの空気質
ISO 8573-1 クラス0(油分含有量)、TÜVラインランドによる独立試験済み
品質と環境
ISO 9001:2015(品質マネジメント)、ISO 14001:2015(環境マネジメント)
⚠️ Critical Safety Advisory – High-Pressure Operation

Nitrogen is classified as a simple asphyxiant gas. At 2.00 MPa discharge pressure, the risk of rapid gas release and oxygen displacement is significantly elevated. All LW-10/20 installations must incorporate continuous oxygen deficiency monitoring in the compressor room and all adjacent areas. High-pressure discharge piping must be equipped with pressure relief valves rated at 110% of MAWP and rupture discs as secondary protection. Ventilation systems must be engineered to maintain ambient oxygen concentrations above 19.5% volume per OSHA 29 CFR 1910.146. Emergency shutdown interlocks should activate at 19.5% O₂ (alarm) and trigger automatic compressor isolation at 18.0% O₂ (hard shutdown). Personnel must be trained in high-pressure gas safety protocols before operating or maintaining this equipment.

LW-10/20 nitrogen compressor ISO certification and compliance documentation

パフォーマンスと効率の分析

The LW-10/20 achieves a specific power consumption of approximately 11.00 kW per m³/min of nitrogen delivered at 2.00 MPa discharge pressure. This specific power figure reflects the thermodynamic reality of high-pressure compression, where the work required increases substantially with pressure ratio. Within the high-pressure oil-free piston compressor segment (discharge pressure >1.50 MPa), this efficiency is competitive and often superior to diaphragm compressors, which are the primary alternative for oil-free high-pressure service. For comparison, oil-lubricated reciprocating compressors in similar high-pressure applications typically consume 11.5–13.0 kW/m³/min, while diaphragm compressors may exceed 15 kW/m³/min.

Over a standard 8,000-hour annual operating schedule, the LW-10/20’s efficiency advantage versus less efficient alternatives yields approximately 40,000–80,000 kWh of annual energy savings. At $0.08/kWh, this represents $3,200–$6,400 in direct electricity cost reduction per year. However, the primary economic justification for the LW-10/20 is typically the 石油関連消耗品の排除と下流の油除去装置の回避 that would be mandatory with lubricated alternatives. The total cost of ownership for high-pressure nitrogen compression is reduced by an estimated 25–35% over a 10-year operational life when oil-free operation is compared to lubricated systems with full downstream purification.

The absence of oil in the compression path is particularly valuable at high pressure because oil contamination becomes more concentrated and more difficult to remove as pressure increases. At 2.00 MPa, the partial pressure of oil vapor is significantly higher than at 0.30 MPa, making downstream oil-filtration systems less effective and more expensive. The LW-10/20’s native oil-free design eliminates this challenge entirely.

カスタマイズおよびOEM対応

We offer comprehensive customization options to adapt the LW-10/20 to specific site conditions, integration requirements, and end-user specifications:

  • スキッドマウント型ターンキーパッケージ: Pre-assembled compressor, motor, intercooler, aftercooler, high-pressure discharge piping, instrumentation, and control panel on a structural steel skid with integrated lifting lugs and anchor bolt templates. Reduces field installation to electrical connection and cooling water hookup only.
  • 危険区域構成: ATEX Zone 2 and IECEx compliant motor and electrical enclosures for petrochemical installations. Integrated gas detection and automatic ventilation interlocks can be incorporated into the control system.
  • 高度なプロセス制御: Optional Siemens S7-1200 or Allen-Bradley CompactLogix PLC with 10-inch HMI touchscreen, remote monitoring via Modbus TCP/IP or OPC-UA, and seamless DCS/SCADA integration. High-pressure safety interlocks including automatic unload on overpressure and emergency isolation valves.
  • 環境保護: 沿岸設置向けのC5-M海洋グレードコーティング、周囲温度55℃に対応した耐熱電気部品、1メートル地点での騒音を85dB(A)から72dB(A)に低減するIP54規格の防音筐体。
  • OEMおよびプライベートブランド: ガス機器販売業者およびシステムインテグレーター向けに、特注の塗装色、ブランドロゴ入りの銘板、地域に合わせたドキュメントを提供します。

カスタム構成は以下から入手可能です 最小注文数量:1個. Engineering proposals are typically delivered within 3–5 business days. Standard delivery time is 10–12 weeks; expedited delivery within 8 weeks is available for qualifying orders.

LW-10/20 nitrogen compressor custom skid mounted high pressure package

Case Study: Pharmaceutical Nitrogen Cylinder Filling Station

クライアント: A pharmaceutical gas supplier in India serving hospitals and pharmaceutical manufacturers

チャレンジ: The client was operating an oil-lubricated high-pressure compressor for filling medical-grade nitrogen cylinders. Oil contamination levels in the filled cylinders reached 1.5 mg/m³, exceeding the 0.1 mg/m³ specification required by pharmaceutical customers and hospital gas standards. The oil was also degrading the activated carbon purification beds in the cylinder filling manifold, requiring replacement every 6 months. Customer complaints and regulatory scrutiny were increasing.

解決: 私たちは供給しました LW-10/20 oil-free nitrogen compressor as the primary booster, configured on a custom skid with integrated intercooler, aftercooler, and a Siemens S7-1200 PLC control panel. The 2.00 MPa discharge pressure fed a downstream high-pressure filling compressor, reducing the overall compression ratio required of the filling stage and improving system efficiency. The oil-free design eliminated the need for activated carbon purification beds entirely.

18か月後の定量的な結果:

  • Nitrogen oil content in filled cylinders: 1.5 mg/m³から0.01 mg/m³未満に減少ISO 8573-1クラス0を達成
  • Activated carbon bed replacement: 完全に排除された, saving $8,000/year in consumables
  • Customer complaints: Zero since commissioning, with three new pharmaceutical contracts won
  • Filling compressor maintenance: Reduced by 30% due to lower inlet pressure ratio
  • Payback period: 2.1 years based on cost savings and new contract revenue

“The LW-10/20 has been a game-changer for our medical gas business. We now guarantee ISO 8573-1 Class 0 nitrogen to all our customers, and we’ve won contracts that we couldn’t compete for before. The oil-free design has eliminated our biggest quality headache.” — Managing Director, Pharmaceutical Gas Supplier

LW-10/20 nitrogen compressor pharmaceutical cylinder filling installation

よくある質問と選択ガイド

What is the expected service life of the LW-10/20 under high-pressure operating conditions?

The LW-10/20 is engineered for a minimum design life of 12 years (approximately 100,000 operating hours) in clean nitrogen service at high pressure. The cast-iron frame and forged steel crankshaft are rated for the full design life. The PTFE piston rings and rider bands are the primary wear components, with a typical replacement interval of 3,000–5,000 hours under high-pressure conditions. Valve plate assemblies generally achieve 2,000–3,500 hours before requiring refurbishment due to the increased mechanical stress at 2.00 MPa.

Can the LW-10/20 be used for direct cylinder filling to 15–20 MPa?

The LW-10/20’s maximum discharge pressure is 2.00 MPaこれは、15~20 MPa の直接シリンダー充填には不十分です。しかし、優れた 中間ブースター in a staged compression system. By boosting nitrogen from 0.05–0.10 MPa to 2.00 MPa, the LW-10/20 dramatically reduces the compression ratio required of the downstream high-pressure filling compressor, improving overall system efficiency and reducing wear on the expensive high-pressure stage. This is the recommended configuration for cylinder filling applications.

Is the LW-10/20 suitable for outdoor installation?

The standard LW-10/20 is designed for 屋内設置 in a ventilated machinery room. For outdoor use, we offer an optional IP54防水筐体 with space heating (for -20°C climates), solar shields (for 55°C ambient), and forced ventilation. The acoustic enclosure option is recommended for outdoor installations to maintain noise compliance (75 dB(A) at property boundary).

How does the LW-10/20 compare to diaphragm compressors for high-pressure oil-free nitrogen?

Diaphragm compressors offer absolute oil-free compression and can achieve very high pressures (up to 300 MPa), but they suffer from lower capacity, higher specific power consumption, and significantly higher capital cost compared to piston compressors. The LW-10/20 delivers 10 m³/min at approximately 11 kW/m³/min, while an equivalent diaphragm compressor would deliver 2–3 m³/min at 15+ kW/m³/min and cost 3–5 times more. For applications where 2.00 MPa is sufficient, the LW-10/20 offers a compelling combination of capacity, efficiency, and cost-effectiveness. For pressures above 3.00 MPa, diaphragm or multi-stage piston compressors become necessary. See our 窒素圧縮機のROI分析 詳細な比較については、こちらをご覧ください。

When should I avoid selecting the LW-10/20?

The LW-10/20 is NOT recommended for: (1) Discharge pressures above 2.50 MPa—consider our DW series or ZW multi-stage series for higher pressure requirements; (2) Capacity requirements above 20 m³/min—larger LW-series models offer better scale efficiency; (3) Applications requiring discharge pressure below 0.80 MPa—lower-pressure models such as the LW-52/3 or LW-40/4 offer significantly better specific power consumption and should be selected for low-pressure applications; (4) Continuous flow modulation below 40% of rated capacity—piston compressors are less efficient at deep turndown.

関連製品およびソリューション

DWシリーズ高圧窒素コンプレッサー

Designed for discharge pressures from 0.40 MPa to 2.00 MPa, the DW series covers nitrogen injection, high-pressure pipeline boosting, and chemical synthesis. Capacities from 2 to 130 m³/min with multi-stage configurations.

DWシリーズを探索する →

ZWシリーズ 多段式オイルフリーコンプレッサー

酸素、窒素、水素、および特殊ガス用の縦型多段式オイルフリーコンプレッサー。最大吐出圧力は9.00MPaで、超高圧ガス充填や化学プロセス用途に対応します。

ZWシリーズを探索する →

LWシリーズ大容量窒素コンプレッサー

極低温空気分離装置(ASU)のバックアップ、VPSA(真空圧力調整装置)の昇圧、および産業用パイプライン配管向けに設計された、高流量オイルフリーピストンコンプレッサー(20~130 m³/分)。吐出圧力は0.30~0.80 MPa。

LWシリーズを探索する →

当社の包括的な概要については、 工業用窒素圧縮機 オイルフリー酸素圧縮機、水素圧縮機、二酸化炭素圧縮機、および特注設計の特殊ガスソリューションを含む製品ポートフォリオの詳細については、当社のアプリケーションエンジニアリングチームにお問い合わせいただくか、オンライン製品カタログをご覧ください。

Ready to Upgrade Your High-Pressure Nitrogen System?

当社のアプリケーションエンジニアが、お客様の窒素流量要件、吸引条件、吐出圧力目標、およびシステム統合上の制約を評価するために待機しております。お問い合わせをいただいてから48時間以内に、無料の技術提案書、基礎レイアウト図、配管計装図(P&ID)、および詳細な総所有コスト(TCO)分析をご提供いたします。