LW-40/18 Nitrogen Compressor – High-Pressure Oil-Free N2 Booster for Demanding Industrial Applications

説明

LW-40/18 Nitrogen Compressor – High-Pressure Oil-Free N2 Booster for Demanding Industrial Applications

Engineered to deliver 40 m³/min at 1.80 MPa discharge pressure, the LW-40/18 is a two-stage, two-row oil-free piston nitrogen compressor purpose-built for high-pressure nitrogen injection, gas liquefaction pre-compression, and critical petrochemical process applications. Zero oil contamination, continuous-duty rated, and optimized for sustained operation at elevated pressure.

LW-40/18 nitrogen compressor high pressure oil-free industrial unit

製品概要

LW-40/18 nitrogen compressor occupies a unique position at the intersection of substantial flow capacity and elevated discharge pressure within our oil-free piston compressor portfolio. With a rated capacity of 40 m³/min そして並外れた 1.80 MPa discharge pressure, this unit addresses the most demanding nitrogen compression requirements in industrial gas infrastructure where both high flow and high pressure are simultaneously required.

What distinguishes the LW-40/18 from conventional high-pressure alternatives is its completely oil-free compression mechanism. The piston rings and rider bands are fabricated from advanced self-lubricating PTFE composite materials that operate without any hydrocarbon lubricants. This intrinsic oil-free characteristic ensures the nitrogen product stream achieves ISO 8573-1 クラス0認証 natively, making the unit immediately suitable for food-grade nitrogen, pharmaceutical process gas, electronics-grade inerting, and petrochemical reactor blanketing without additional downstream purification equipment.

The compressor architecture follows a 二段二列 (二列二级) configuration that optimally manages the substantial pressure ratio required for 1.80 MPa discharge. By dividing the compression duty across two cylinders with an inter-stage cooler, the LW-40/18 maintains thermal stability and preserves the integrity of the PTFE sealing elements even under sustained maximum-load operation. The robust construction—2860 × 1685 × 2610 mm そして 7.00 tonnes—reflects the heavy-duty engineering required for high-pressure industrial service.

LW-40/18 nitrogen compressor high pressure two stage piston design

Technical Specifications – LW-40/18

パラメータ 価値 ユニット
モデル LW-40/18
パターン 二段二列 (二列二级)
容量 40 m³/分
吐出圧力 1.80 MPa
コンプレッサーのサイズ(長さ×幅×高さ) 2860 × 1685 × 2610 mm
重さ 7.00 t
400 kW
電圧 6,000円または10,000円 V
ガス媒体 窒素(N₂)
潤滑 オイルフリー

* すべての仕様は標準基準条件(ISO 1217、附属書C)に基づいています。実際の性能は、設置場所の標高、周囲温度、および吸気条件によって異なる場合があります。

主な特長とエンジニアリング上の利点

1. High-Pressure Oil-Free PTFE Sealing Technology

The LW-40/18 employs a specialized self-lubricating piston ring and rider band system manufactured from high-performance PTFE composites reinforced with glass fiber, bronze particulates, and molybdenum disulfide. This advanced material formulation achieves a coefficient of friction below 0.05 without any external hydrocarbon lubrication, completely eliminating oil vapor carryover risk. The rings are specifically engineered for the elevated discharge temperatures and pressures associated with 1.80 MPa operation, maintaining dimensional stability and sealing integrity up to 200°C. For operators in regulated industries, this delivers native ISO 8573-1 Class 0 compliance without downstream filtration capital or operating costs.

2. Two-Stage Compression for Extreme Pressure Ratios

2段階圧縮アーキテクチャ of the LW-40/18 is thermodynamically essential for managing the extreme pressure ratio required to achieve 1.80 MPa discharge from near-atmospheric suction. By dividing the compression duty between a low-pressure cylinder and a high-pressure cylinder, the compressor limits the discharge temperature of each stage to below 165°C. A high-efficiency shell-and-tube intercooler between stages removes the heat of compression, preventing thermal degradation of the PTFE sealing elements and extending valve plate service life by approximately 45% compared to single-stage designs attempting equivalent pressure ratios. This staged approach is fundamental to achieving reliable continuous operation at 1.80 MPa.

3. Reinforced Heavy-Duty Frame for High-Pressure Service

メインフレームは鋳造されています GG30 グレー鋳鉄 (equivalent to ASTM A48 Class 35B) with thicker wall sections and reinforced ribbing compared to lower-pressure models. The integral cooling water passages are precision-machined to ensure uniform thermal distribution across the cylinder block. The two-row opposed-cylinder arrangement provides natural first-order force cancellation, reducing unbalanced inertia forces transmitted to the foundation by over 80% versus single-row designs. Despite the 7.00-tonne weight, this mechanical balance permits installation on a reinforced concrete inertia block of 12–14 tonnes, significantly lighter than would be required for an equivalent single-row high-pressure compressor.

4. High-Power Medium-Voltage Motor Drive

The LW-40/18 is driven by a 400 kW medium-voltage induction motor available in either 6kV or 10kV configurations, conforming to IEC 60034-1 efficiency class IE3. The 400 kW power rating reflects the substantial energy input required for high-pressure compression at 40 m³/min capacity. Direct integration into industrial medium-voltage distribution networks eliminates the need for oversized low-voltage switchgear and heavy-gauge cabling. For facilities with existing 6kV or 10kV bus systems, the LW-40/18 offers seamless electrical compatibility, reducing infrastructure costs and improving overall energy efficiency through lower I²R losses.

LW-40/18 nitrogen compressor general assembly heavy duty high pressure design

アプリケーションシナリオ

High-Pressure Nitrogen Injection for Enhanced Oil Recovery

In oilfield operations, the LW-40/18 serves as the primary high-pressure nitrogen injection compressor for enhanced oil recovery (EOR) and pressure maintenance programs. The 1.80 MPa discharge pressure is sufficient for direct injection into reservoir formations at depths up to 1,500 meters, where nitrogen displaces crude oil and maintains reservoir pressure. The 40 m³/min capacity supports multiple injection wells operating simultaneously. The oil-free design is critical in EOR applications because any hydrocarbon contamination from lubricated compressors would alter reservoir wettability and reduce oil displacement efficiency, directly impacting production yields.

LW-40/18 nitrogen compressor high pressure injection oilfield application

Gas Liquefaction Pre-Compression

In small to medium-scale LNG and industrial gas liquefaction plants, the LW-40/18 nitrogen compressor provides the high-pressure nitrogen required for pre-cooling and liquefaction cycle support. The 1.80 MPa discharge pressure is adequate for nitrogen expander cycles and mixed-refrigerant pre-cooling systems. The oil-free compression path ensures that nitrogen used for process inerting and equipment purging does not introduce contaminants that could freeze out in cryogenic heat exchangers, causing blockages and operational disruptions.

Petrochemical Reactor Inerting & Catalyst Preservation

In petrochemical and refinery operations, the LW-40/8 provides high-pressure nitrogen for reactor inerting during startup and shutdown, catalyst bed preservation during extended outages, and emergency nitrogen injection into process vessels. The 1.80 MPa discharge pressure exceeds the operating pressure of most process reactors and vessels, allowing direct nitrogen injection without intermediate boosting. The continuous-duty rating ensures nitrogen availability during extended turnaround campaigns lasting several weeks. The oil-free certification is mandatory for applications where nitrogen contacts catalyst beds or enters process streams that must remain completely hydrocarbon-free.

LW-40/18 nitrogen compressor petrochemical reactor inerting application

高圧パイプラインの試験および試運転

Natural gas and process pipeline construction projects require high-pressure nitrogen for hydrostatic testing, leak testing, drying, and commissioning before introducing hydrocarbon products. The LW-40/18’s 1.80 MPa discharge pressure is suitable for pressure testing pipelines rated up to Class 600 (ANSI B16.5). The 40 m³/min capacity enables rapid pressurization of long pipeline sections, reducing commissioning time and labor costs. The oil-free design prevents oil contamination of pipeline interiors that would require costly cleaning before product introduction.

材料と構造

The LW-40/18 is constructed from premium materials specifically selected for high-pressure nitrogen service, corrosion resistance, and extended operational life under demanding conditions:

成分 材料 仕様
シリンダーブロック ねずみ鋳鉄 GG30 / HT300, reinforced wall sections, integral cooling jackets
クランクシャフト 鍛造合金鋼 42CrMo4, Q&T, ISO 1940 G2.5 dynamically balanced, nitrided journals
ピストンリング PTFE-ガラス-青銅-MoS₂複合材 Self-lubricating, high-temp rated to 200°C, wear rate <0.03 mm/1000h
ライダーバンド PTFE複合材 Piston guidance, anti-scuffing, high-load capacity
バルブプレート ステンレス鋼 SS316, concentric ring spring-loaded, high-pressure rated
コネクティングロッド 鍛造鋼製、バビットメタルベアリング使用 Precision-machined, pressure-lubricated big end, high-load design
インタークーラー 炭素鋼製シェル/SS316製チューブ ASME VIII Div.1、1.5倍の耐圧試験、30分間保持
アフタークーラー 炭素鋼製シェル/SS316製チューブ High-pressure finned tube design, 32°C cooling water rated
高圧配管 Seamless Carbon Steel ASTM A106 Grade B, Schedule 80, 100% X-ray inspected

すべての圧力支持部品は、以下の基準に厳密に従って設計および製造されています。 ASME BPVC セクション VIII ディビジョン 1 or Chinese GB 150 standards. Every weld joint undergoes 100% radiographic inspection (RT) per ASME Section V, Article 2. Each completed pressure vessel is subjected to a hydrostatic pressure test at 1.5 times the maximum allowable working pressure (MAWP) for a minimum hold period of 30 minutes. High-pressure piping connections are 100% ultrasonic tested (UT) to detect any internal defects.

LW-40/18 nitrogen compressor factory high pressure component manufacturing

設置およびメンテナンスに関するガイドライン

基礎および構造要件

The LW-40/18 has a dry weight of 7.00 tonnes and a center of gravity approximately 950 mm above the baseplate. The two-row opposed-cylinder design minimizes unbalanced forces, permitting installation on a reinforced concrete inertia block of 12–14 tonnes. The block must be mounted on heavy-duty elastomeric vibration isolators (natural frequency 5–7 Hz) to prevent vibration transmission to adjacent structures and sensitive instrumentation. Minimum clearance requirements: 1.5 m on the non-drive side for valve access, 1.2 m on the drive side for motor maintenance, and 2.5 m overhead for crane access during major overhauls. The foundation must be designed to withstand the dynamic loads associated with 400 kW motor starting torque.

冷却水システムの設計

冷却水の需要は約 48 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit supplies the cylinder jackets, intercooler, and aftercooler in parallel branches with individual flow control valves. Water quality specifications are stringent due to the high-pressure service: pH 6.5–8.5, total dissolved solids < 400 mg/L, chloride content < 40 mg/L (to prevent SS316 tube corrosion), suspended solids < 20 mg/L, and total hardness < 250 mg/L as CaCO₃. For sites with marginal water quality, a closed-loop cooling tower with side-stream filtration, water softening, and chemical treatment is mandatory to prevent scale formation and corrosion in the high-pressure coolers.

予防保守スケジュール

間隔 サービス項目 対応が必要
毎日 運用検査 Check vibration levels, abnormal noise, cooling water flow, discharge temperature, pressure relief valve integrity
250時間 バルブプレートの点検 Remove and inspect suction/discharge valves for carbon deposits, spring fatigue, cracking, or seat erosion
1,000時間 ピストンリング摩耗評価 リング溝のクリアランスを測定し、クリアランスが0.20mmを超える場合はリングを交換してください。
3,000時間 中間オーバーホール Replace all piston rings, rider bands, and valve plate assemblies; inspect intercooler tubes
6,000時間 大規模な改修 Inspect crankshaft journals, measure main and big-end bearing clearances, replace bearings if >0.06 mm

The oil-free design of the LW-40/18 dramatically simplifies maintenance compared to lubricated alternatives. There are no oil changes, no oil analysis, no filter replacements, and no separator cartridge changes. The primary consumable wear items are the PTFE製ピストンリングおよびライダーバンド, which typically achieve 3,000–5,000 hours of service life under clean nitrogen conditions at high pressure. Valve plate assemblies generally require refurbishment at 2,000–3,500 hours due to the elevated operating pressures.

LW-40/18 nitrogen compressor workshop assembly and high pressure testing

法令遵守および安全認証

The LW-40/18 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:

圧力機器指令
ASME BPVC セクション VIII Div.1、GB 150-2011、PED 2014/68/EU モジュール A
電気および機械の安全
IEC 60034-1(IE3効率)、IEC 60204-1、ISO 12100機械安全規格
オイルフリーの空気質
ISO 8573-1 クラス0(油分含有量)、TÜVラインランドによる独立試験済み
品質と環境
ISO 9001:2015(品質マネジメント)、ISO 14001:2015(環境マネジメント)
⚠️ 重大な安全上の注意

Nitrogen is classified as a simple asphyxiant gas. At 1.80 MPa, nitrogen releases from the LW-40/18 pose additional hazards due to high-velocity gas jets and rapid expansion cooling. All installations must incorporate continuous oxygen deficiency monitoring in the compressor room and all adjacent areas. Ventilation systems must maintain ambient oxygen above 19.5% volume per OSHA 29 CFR 1910.146. Emergency shutdown interlocks should activate at 19.5% O₂ (alarm) and trigger automatic compressor isolation at 18.0% O₂ (hard shutdown). High-pressure relief systems must discharge to safe locations away from personnel areas. All high-pressure piping must be protected against mechanical damage and clearly marked with pressure ratings.

LW-40/18 nitrogen compressor ISO certification and compliance documentation

パフォーマンスと効率の分析

The LW-40/18 achieves a specific power consumption of approximately 10.00 kW per m³/min of nitrogen delivered at 1.80 MPa discharge pressure. This efficiency metric reflects the substantial thermodynamic work required for high-pressure compression and is competitive within the high-pressure oil-free piston compressor segment. For comparison, oil-lubricated screw compressors operating at equivalent pressure ratios typically consume 10.5–12.0 kW/m³/min, while multi-stage diaphragm compressors (often selected for high-pressure oil-free applications) can exceed 14 kW/m³/min.

Over a standard 8,000-hour annual operating schedule, the LW-40/18’s efficiency advantage generates approximately 160,000–400,000 kWh of annual energy savings compared to less efficient alternatives. At an average industrial electricity tariff of $0.08/kWh, this represents $12,800–$32,000 in direct operating cost reduction per year. However, the primary economic justification for the LW-40/18 is typically the elimination of oil-related consumables and the avoidance of downstream purification equipment that would be mandatory with lubricated alternatives.

total cost of ownership for high-pressure nitrogen compression is further reduced by the absence of oil in the compression path. A typical oil-lubricated compressor of this pressure rating would require high-pressure coalescing filters, activated carbon adsorbers, continuous oil monitoring, and periodic oil replacement that collectively add $15,000–$25,000 annually in operating costs. The LW-40/18’s oil-free design eliminates these expenses entirely while delivering superior product purity.

カスタマイズおよびOEM対応

We offer comprehensive customization options to adapt the LW-40/18 to specific site conditions, integration requirements, and end-user specifications:

  • スキッドマウント型ターンキーパッケージ: The compressor, motor, intercooler, aftercooler, high-pressure instrumentation, and control panel are pre-assembled on a reinforced structural steel skid with integrated lifting lugs and anchor bolt templates. Factory pre-testing of all systems reduces field commissioning time by approximately 60%.
  • 危険区域構成: ATEX Zone 2 and IECEx compliant motor and electrical enclosures are available for oilfield and petrochemical installations. Integrated gas detection, automatic ventilation interlocks, and explosion-proof instrumentation can be incorporated into the control system.
  • 高度なプロセス制御: Optional Siemens S7-1200 or Allen-Bradley CompactLogix PLC with 10-inch HMI touchscreen, remote monitoring via Modbus TCP/IP or OPC-UA, and seamless DCS/SCADA integration. Automatic load/unload control, anti-surge protection, and emergency shutdown logic are standard.
  • High-Pressure Package Options: Integrated high-pressure storage vessels, pressure regulation skids, and distribution manifolds can be supplied as part of a complete nitrogen injection package. All high-pressure components are designed and tested to the same standards as the compressor.
  • OEMおよびプライベートブランド: Custom paint colors, branded nameplates, and localized documentation packages are available for gas equipment distributors and system integrators serving oilfield and industrial markets.

カスタム構成は以下から入手可能です 最小注文数量:1個. Engineering review and proposal generation typically require 7–10 business days due to the complexity of high-pressure applications. Standard delivery time is 14–16 weeks; repeat orders are delivered in 10–12 weeks from order confirmation.

LW-40/18 nitrogen compressor custom high pressure skid package installation

Case Study: Oilfield Nitrogen Injection for Enhanced Recovery

クライアント: An independent oil producer operating mature oilfields in the Middle East

チャレンジ: The client’s oilfields had entered decline phase with reservoir pressure dropping below the bubble point, causing gas breakout and reduced oil mobility. Conventional waterflooding was ineffective due to reservoir heterogeneity. The client required high-pressure nitrogen injection to maintain reservoir pressure and improve sweep efficiency, but existing oil-lubricated compressors were contaminating the injection gas with hydrocarbons, altering reservoir wettability and reducing displacement efficiency.

解決: 私たちは供給しました LW-40/18 oil-free nitrogen compressor configured on a custom skid with integrated high-pressure aftercooler, moisture separator, and a Siemens S7-1200 PLC control panel with remote monitoring. The 1.80 MPa discharge pressure enabled direct injection into reservoir formations at 1,200–1,400 meters depth. A 10 m³ high-pressure surge vessel was installed downstream to buffer injection rate fluctuations. The skid was designed for desert operation with sand filtration, high-ambient-temperature cooling, and C5-M corrosion protection.

36か月後の定量的な結果:

  • Reservoir pressure: Maintained at 85% of original versus 62% with waterflooding alone
  • Oil production rate: Increased by 18% compared to pre-nitrogen injection baseline
  • 窒素油含有量: <0.01 mg/m³, eliminating reservoir wettability alteration
  • Compressor availability: 97.5% over 36 months, with only scheduled maintenance shutdowns
  • Operating cost: 32% lower than the previous oil-lubricated compressor system due to elimination of oil-related maintenance

“The LW-40/18 has been the cornerstone of our nitrogen EOR program. The oil-free design gives us confidence that we’re not compromising reservoir performance, and the reliability has exceeded our expectations in a harsh desert environment.” — Reservoir Engineering Manager

LW-40/18 nitrogen compressor oilfield injection installation case study

よくある質問と選択ガイド

What is the expected service life of the LW-40/18 under high-pressure operating conditions?

The LW-40/18 is engineered for a minimum design life of 12 years (approximately 100,000 operating hours) in clean nitrogen service at high pressure. The reinforced cast-iron frame and nitrided crankshaft are rated for the full design life. The PTFE piston rings and rider bands are the primary wear components, with a typical replacement interval of 3,000–5,000 hours at 1.80 MPa due to the elevated mechanical and thermal stresses. Valve plate assemblies generally require refurbishment at 2,000–3,500 hours under high-pressure conditions.

Can the LW-40/18 handle variable inlet pressure from a cryogenic nitrogen source?

Yes. The LW-40/18 can accommodate inlet pressure variations from 0.05 MPa to 0.15 MPa without performance degradation. For cryogenic nitrogen vaporizer applications where inlet pressure may fluctuate with ambient temperature and vaporizer performance, we recommend installing a 最小容量5m³のサージ容器 upstream of the compressor suction to dampen pressure pulsations and provide a stable suction condition. For severe pulsation conditions, an optional pulsation dampener and suction stabilizer can be fitted.

Is the LW-40/18 suitable for outdoor installation in extreme climates?

The standard LW-40/18 is designed for 屋内設置 in a ventilated machinery room. For outdoor installation in extreme climates, we offer a heavy-duty IP54防水筐体 with integrated space heating (for cold climates down to -30°C), high-capacity cooling (for tropical climates up to 55°C ambient), sand filtration (for desert environments), and forced ventilation. The acoustic enclosure option reduces noise emission from 88 dB(A) to 75 dB(A) at 1 meter. All outdoor packages include corrosion protection to C5-M marine grade.

How does the LW-40/18 compare to multi-stage diaphragm compressors for high-pressure nitrogen?

While multi-stage diaphragm compressors offer absolute leak-tightness (zero gas leakage to atmosphere), they typically consume 30–40% more energy than piston compressors at equivalent pressure ratios and have significantly lower capacity per unit (typically 5–15 m³/min). The LW-40/18 offers a compelling balance: native oil-free operation with near-zero leakage ( piston ring sealing), substantially higher capacity (40 m³/min), and significantly better energy efficiency. For applications where moderate leakage is acceptable and high capacity is required, the LW-40/18 is the economically superior choice. For applications requiring absolute zero leakage (toxic or radioactive gas service), diaphragm compressors remain the appropriate technology. For a detailed comparison, refer to our high-pressure nitrogen compressor ROI analysis.

Under what circumstances should I avoid selecting the LW-40/18?

The LW-40/18 is NOT the optimal choice for: (1) Discharge pressures exceeding 2.50 MPa—for higher pressure requirements, consider our ZW multi-stage series (up to 9.00 MPa) or specialized high-pressure diaphragm compressors; (2) 容量要件が15 m³/分未満—smaller units in the ZW or MW series offer better part-load efficiency and lower capital cost; (3) Applications requiring absolute zero gas leakage—diaphragm compressors are the appropriate technology for toxic, radioactive, or extremely expensive gas service where any leakage is unacceptable; (4) Continuous flow modulation below 40% of rated capacity—piston compressors experience reduced efficiency at deep turndown; a dual-compressor arrangement may be preferable for highly variable demand.

関連製品およびソリューション

ZW Series Multi-Stage High-Pressure Compressors

Vertical, multi-stage oil-free compressors for oxygen, nitrogen, hydrogen, and specialty gases. Discharge pressures up to 9.00 MPa for ultra-high-pressure gas filling, cylinder charging, and specialized chemical process applications.

ZWシリーズを探索する →

DW Series Medium-Pressure Nitrogen Compressors

Medium to high-pressure oil-free compressors (0.40–2.00 MPa) for nitrogen injection, pipeline boosting, and chemical synthesis. Capacities from 2 to 130 m³/min with two-stage and multi-stage configurations.

DWシリーズを探索する →

MW Series Medium-Pressure Compressors

Medium-pressure oil-free compressors (1.0–4.0 MPa) for nitrogen recycle, gas liquefaction booster duty, and process gas compression in petrochemical and refinery operations.

Explore MW Series →

当社の包括的な概要については、 工業用窒素圧縮機 オイルフリー酸素圧縮機、水素圧縮機、二酸化炭素圧縮機、および特注設計の特殊ガスソリューションを含む製品ポートフォリオの詳細については、当社のアプリケーションエンジニアリングチームにお問い合わせいただくか、オンライン製品カタログをご覧ください。

Ready to Deploy High-Pressure Nitrogen Compression?

Our application engineers are standing by to evaluate your high-pressure nitrogen requirements, suction conditions, discharge pressure targets, and integration constraints. We provide complimentary technical proposals, foundation layout drawings, piping and instrumentation diagrams (P&IDs), and detailed total cost of ownership (TCO) analyses within 48 hours of receiving your inquiry.

メールアドレス: [email protected] 24時間以内に返信いたします