ZW-13/30 Nitrogen Compressor – Medium-Capacity Oil-Free N2 Booster for 3.00 MPa High-Pressure Process Applications

説明

ZW-13/30 Nitrogen Compressor – Medium-Capacity Oil-Free N2 Booster for 3.00 MPa High-Pressure Process Applications

Engineered to deliver 13 m³/min at 3.00 MPa discharge pressure, the ZW-13/30 is a two-stage, three-row oil-free piston nitrogen compressor designed for demanding high-pressure nitrogen injection, gas cylinder filling stations, and critical petrochemical process applications. Zero oil contamination, robust three-row force balance, and optimized for continuous-duty operation at elevated pressure.

 

製品概要

ZW-13/30 nitrogen compressor represents a powerful mid-range solution within our oil-free piston compressor family, engineered for applications where both substantial flow capacity and high discharge pressure are simultaneously required. With a rated capacity of 13 m³/min 吐出圧力 3.00 MPa, this unit occupies a critical position in the high-pressure nitrogen compressor market, bridging the gap between small laboratory-scale units and massive industrial boosters.

What distinguishes the ZW-13/30 from conventional alternatives is its 完全にオイルフリーの圧縮経路 utilizing self-lubricating PTFE composite piston rings and rider bands. This design philosophy eliminates any possibility of hydrocarbon contamination in the nitrogen product stream, achieving ISO 8573-1 クラス0認証 natively. At 3.00 MPa discharge pressure, the risk of oil vapor carryover is substantially magnified compared to low-pressure applications, making the oil-free design not merely advantageous but absolutely mandatory for food-grade, pharmaceutical, and electronics-grade nitrogen service.

コンプレッサーのアーキテクチャは 二段三列 (二列三级) configuration that is essential for managing the extreme pressure ratio required to achieve 3.00 MPa from typical inlet conditions. The three-row opposed-cylinder arrangement provides superior force balance compared to two-row designs, reducing vibration transmission and permitting installation on lighter foundations. Each compression stage is equipped with an independent high-efficiency intercooler, ensuring gas temperatures remain within safe operating envelopes even during sustained maximum-load operation. The robust cast-iron frame and dynamically balanced forged steel crankshaft are rated for a minimum service life of 12万時間 標準的な保守手順に従って。

ZW-13/30 nitrogen compressor three row high pressure piston assembly

Technical Specifications – ZW-13/30

パラメータ 価値 ユニット
モデル ZW-13/30
パターン 二段三列(二列三级)
容量 13 m³/分
吐出圧力 3.00 MPa
コンプレッサーのサイズ(長さ×幅×高さ) 2764 × 2000 × 3277 mm
重さ 6.00 t
160 kW
電圧 380 V
ガス媒体 窒素(N₂)
潤滑 オイルフリー

* すべての仕様は標準基準条件(ISO 1217、附属書C)に基づいています。実際の性能は、設置場所の標高、周囲温度、および吸気条件によって異なる場合があります。

主な特長とエンジニアリング上の利点

1. Three-Row Opposed-Cylinder Force Balance

The ZW-13/30 employs a unique three-row opposed-cylinder arrangement (二列三级) that provides exceptional first-order and second-order force cancellation. By distributing the compression work across three cylinders arranged in an opposed configuration, the compressor achieves near-perfect inertial force balance, reducing vibration transmission to the foundation by over 90% compared to single-row designs. This mechanical advantage is particularly critical for high-pressure compressors where the peak gas forces on the pistons are substantially higher than in low-pressure applications. The three-row design permits installation on a lighter reinforced concrete inertia block (minimum 10 tonnes versus 15+ tonnes for equivalent single-row units), significantly reducing civil engineering costs and simplifying retrofit installations in existing process plants.

2. High-Pressure Oil-Free PTFE Composite Sealing

The ZW-13/30 utilizes a proprietary 自己潤滑ピストンリングおよびライダーバンドアセンブリ manufactured from high-density PTFE composites specifically formulated for high-pressure service. These rings are reinforced with glass fiber and bronze particulates to achieve a coefficient of friction below 0.05 without any external hydrocarbon lubrication. At 3.00 MPa discharge pressure, the partial pressure of oil vapor would be approximately 10 times higher than at 0.30 MPa, making oil contamination far more concentrated and difficult to remove. The ZW-13/30’s native oil-free design achieves ISO 8573-1 クラス0認証 without any downstream filtration, eliminating both the capital cost and the energy penalty of oil-removal equipment. The PTFE formulation is rated for continuous operation at temperatures up to 185°C, ensuring reliable sealing integrity under the extreme thermal stress of high-pressure compression.

3. Two-Stage Thermodynamic Optimization for Extreme Pressure Ratios

2段階圧縮アーキテクチャ of the ZW-13/30 is thermodynamically essential for achieving the 3.00 MPa discharge pressure target from typical inlet pressures of 0.05–0.10 MPa. The overall pressure ratio of approximately 30:1 to 60:1 is divided between a low-pressure cylinder group and a high-pressure cylinder group, with each stage operating at a manageable pressure ratio. A high-efficiency shell-and-tube intercooler between stages removes the substantial heat of compression, maintaining discharge temperatures below 160°C and preventing thermal degradation of the PTFE sealing elements. Without staged compression, the discharge temperature would exceed 250°C, far beyond the safe operating limit of any oil-free sealing material. The inter-stage cooling is therefore not merely an efficiency enhancement but a fundamental requirement for reliable high-pressure oil-free operation.

4. Standard 380V Industrial Motor Drive with High Efficiency

The ZW-13/30 is driven by a 160 kW, 380V, 50Hz three-phase induction motor conforming to IEC 60034-1 efficiency class IE3. The standard low-voltage configuration integrates directly into existing 380V industrial distribution panels without requiring medium-voltage switchgear or step-down transformers. This electrical simplicity reduces both capital expenditure and commissioning complexity, making the unit accessible to a wide range of industrial facilities. For sites with 6kV or 10kV bus systems, an optional motor with integrated step-down transformer can be supplied on a common skid, providing seamless integration into any electrical infrastructure.

ZW-13/30 nitrogen compressor general assembly three row high pressure design

アプリケーションシナリオ

High-Pressure Nitrogen Cylinder Filling Stations

The ZW-13/30 is ideally suited for industrial nitrogen cylinder filling operations where high-pressure gas must be compressed into standard industrial cylinders at 15–20 MPa filling pressure. While the compressor’s 3.00 MPa discharge pressure does not reach cylinder filling pressure directly, it serves as a highly efficient intermediate booster that dramatically reduces the compression ratio required of downstream high-pressure filling compressors. The 13 m³/min capacity can supply multiple filling manifolds simultaneously, making the ZW-13/30 suitable for commercial gas filling stations serving industrial, medical, and specialty gas markets. The oil-free design is mandatory for cylinder filling because any oil contamination would be trapped in the cylinders and delivered to end-users, potentially compromising their processes and creating liability exposure.

ZW-13/30 nitrogen compressor high pressure cylinder filling station

Petrochemical High-Pressure Process Nitrogen

In petrochemical and refinery operations, the ZW-13/30 high-pressure nitrogen compressor provides nitrogen for reactor catalyst preservation, emergency injection into high-pressure vessels, pipeline pressure testing, and hydrostatic testing of process equipment. The 3.00 MPa discharge pressure is sufficient to inject nitrogen into process vessels operating at pressures up to 2.5 MPa, maintaining positive inert gas blankets during startup, shutdown, and upset conditions. The continuous-duty rating ensures uninterrupted nitrogen availability during extended turnaround campaigns. The oil-free certification is mandatory for petrochemical applications where nitrogen contacts catalyst beds or enters process streams that must remain completely hydrocarbon-free.

Gas Liquefaction & Cryogenic Storage Booster

In nitrogen liquefaction plants and cryogenic storage facilities, the ZW-13/30 compresses nitrogen from the liquefier vaporizer or storage tank boil-off to the pressure required for distribution or further processing. The 3.00 MPa discharge pressure is sufficient for feeding high-pressure nitrogen into cryogenic storage systems, driving nitrogen through heat exchangers, and supplying high-pressure consumers in the process plant. The 13 m³/min capacity matches the output of small to medium-scale liquefaction plants, making the ZW-13/30 an ideal integrated booster for on-site nitrogen liquefaction systems. The oil-free design prevents contamination of the cryogenic equipment and ensures the purity of liquid nitrogen product.

ZW-13/30 nitrogen compressor gas liquefaction cryogenic storage booster

Pharmaceutical & Food-Grade High-Pressure Nitrogen

Pharmaceutical manufacturing and large-scale food processing facilities require high-purity nitrogen at elevated pressure for sterile filtration, spray drying, aseptic filling, and high-pressure packaging applications. The ZW-13/30’s oil-free certification ensures compliance with FDA 21 CFR 211.72 and EU GMP Annex 1. The 3.00 MPa discharge pressure provides adequate head to drive nitrogen through sterile filtration systems, spray dryers, and high-pressure packaging equipment. The 13 m³/min capacity can simultaneously supply multiple pharmaceutical process lines or food packaging stations within a single manufacturing facility, making the ZW-13/30 a versatile central nitrogen supply solution.

材料と構造

The ZW-13/30 is constructed from premium materials selected for high-pressure nitrogen compatibility, thermal resistance, and extended operational life:

成分 材料 仕様
シリンダーブロック(LP) ねずみ鋳鉄 GG25 / HT250, standard wall thickness
シリンダーブロック(HP) ねずみ鋳鉄 GG25 / HT250, heavy reinforced wall + ribbing
クランクシャフト 鍛造合金鋼 42CrMo4, Q&T, ISO 1940 G2.5 dynamically balanced
ピストンリング PTFE-ガラス-青銅複合材 High-pressure rated, self-lubricating, 185°C max
ライダーバンド PTFE複合材 Piston guidance, anti-scuffing, wear rate <0.04 mm/1000h
バルブプレート ステンレス鋼 SS316, high-pressure concentric ring spring design
コネクティングロッド 鍛造鋼製、バビットメタルベアリング使用 精密加工されたオイル潤滑式ビッグエンド
インタークーラー 炭素鋼製シェル/SS316製チューブ ASME VIII Div.1、1.5倍の耐圧試験、30分間保持
アフタークーラー 炭素鋼製シェル/SS316製チューブ 高圧フィン付きチューブ、32℃冷却水
高圧配管 シームレスステンレス鋼 SS316、ANSIクラス900フランジ
ベースフレーム Structural Steel 溶接構造、振動減衰マウント

すべての圧力支持部品は、以下の基準に厳密に従って設計および製造されています。 ASME BPVC セクション VIII ディビジョン 1 または中国のGB 150規格に準拠しています。すべての溶接継手はASME Section V、Article 2に従って100%放射線検査(RT)を受け、完成した圧力容器はすべて、最大許容使用圧力(MAWP)の1.5倍の圧力で最低30分間の静水圧試験を受けます。高圧配管システムは、3.00 MPaの運転圧力で漏れのない完全性を確保するために、ANSI Class 900フランジ接続を備えたシームレスSS316で製造されています。

ZW-13/30 nitrogen compressor factory precision machining and high pressure testing

設置およびメンテナンスに関するガイドライン

基礎および構造要件

The ZW-13/30 has a dry weight of 6.00 tonnes and a center of gravity approximately 900 mm above the baseplate. Thanks to the three-row opposed-cylinder design, unbalanced forces are minimal despite the high-pressure operation, permitting installation on a reinforced concrete inertia block of 10–12 tonnes. The block should be mounted on elastomeric vibration isolators (natural frequency 6–8 Hz). Minimum clearance requirements: 1.5 m on the non-drive side for valve access, 1.2 m on the drive side for motor maintenance, and 2.0 m overhead for crane access during major overhauls. Special attention must be paid to the high-pressure discharge piping, which must be properly supported, anchored, and stress-relieved to prevent vibration-induced fatigue at 3.00 MPa.

冷却水システムの設計

冷却水の需要は約 28 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit supplies the cylinder jackets, intercooler, and aftercooler in parallel branches. Given the extreme pressure ratio, the intercooler is absolutely critical for thermal management and must receive priority cooling water flow at all times. Water quality specifications: pH 6.5–8.5, total dissolved solids < 500 mg/L, chloride content < 50 mg/L (to prevent SS316 tube corrosion), suspended solids < 30 mg/L, and total hardness < 300 mg/L as CaCO₃. A closed-loop cooling tower with side-stream filtration and chemical treatment is strongly recommended for all installations to ensure consistent water quality.

予防保守スケジュール

間隔 サービス項目 対応が必要
毎日 運用検査 Check vibration, abnormal noise, cooling water flow, discharge pressure, temperature
250時間 バルブプレートの点検 吸込弁/吐出弁を取り外し、カーボン堆積物、スプリング疲労、亀裂がないか点検する。
1,000時間 ピストンリング摩耗評価 リング溝のクリアランスを測定し、クリアランスが0.20mmを超える場合はリングを交換してください。
3,000時間 中間オーバーホール ピストンリング、ライダーバンド、バルブプレートアセンブリをすべて交換してください。
6,000時間 大規模な改修 Inspect crankshaft journals, measure main bearing clearances, replace bearings if >0.08 mm

The oil-free design of the ZW-13/30 dramatically simplifies maintenance compared to lubricated alternatives. There are no oil changes, no oil analysis, no filter replacements, and no separator cartridge changes. The primary consumable wear items are the PTFE製ピストンリングおよびライダーバンド, which typically achieve 3,000–5,000 hours of service life under clean nitrogen conditions at high pressure. The high-pressure valve plates may require more frequent inspection than low-pressure equivalents due to the increased mechanical stress at 3.00 MPa, but the overall maintenance burden remains significantly lower than oil-lubricated systems.

ZW-13/30 nitrogen compressor workshop assembly and quality inspection

法令遵守および安全認証

The ZW-13/30 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:

圧力機器指令
ASME BPVC セクション VIII Div.1、GB 150-2011、PED 2014/68/EU モジュール A
電気および機械の安全
IEC 60034-1(IE3効率)、IEC 60204-1、ISO 12100機械安全規格
オイルフリーの空気質
ISO 8573-1 クラス0(油分含有量)、TÜVラインランドによる独立試験済み
品質と環境
ISO 9001:2015(品質マネジメント)、ISO 14001:2015(環境マネジメント)
⚠️ Critical Safety Advisory – Ultra High-Pressure Operation

Nitrogen is classified as a simple asphyxiant gas. At 3.00 MPa discharge pressure, the risk of rapid gas release and oxygen displacement is severely elevated. All ZW-13/30 installations must incorporate continuous oxygen deficiency monitoring in the compressor room and all adjacent areas. High-pressure discharge piping must be equipped with pressure relief valves rated at 110% of MAWP and rupture discs as secondary protection. All high-pressure connections must be verified with ultrasonic leak detection before commissioning. Ventilation systems must maintain ambient oxygen above 19.5% per OSHA 29 CFR 1910.146. Emergency shutdown interlocks should activate at 19.5% O₂ (alarm) and trigger automatic isolation at 18.0% O₂ (hard shutdown). Personnel must be trained in high-pressure gas safety protocols and must never attempt to disconnect pressurized lines.

ZW-13/30 nitrogen compressor ISO certification and compliance documentation

パフォーマンスと効率の分析

The ZW-13/30 achieves a specific power consumption of approximately 12.31 kW per m³/min of nitrogen delivered at 3.00 MPa discharge pressure. This specific power figure reflects the thermodynamic reality of ultra-high-pressure compression, where the work required increases substantially with pressure ratio. Within the high-pressure oil-free piston compressor segment (discharge pressure >2.50 MPa), this efficiency is competitive and often superior to diaphragm compressors, which are the primary alternative for oil-free high-pressure service. For comparison, oil-lubricated reciprocating compressors in similar ultra-high-pressure applications typically consume 13.0–15.0 kW/m³/min, while diaphragm compressors may exceed 18 kW/m³/min.

Over a standard 8,000-hour annual operating schedule, the ZW-13/30’s efficiency advantage versus less efficient alternatives yields approximately 60,000–140,000 kWh of annual energy savings. At $0.08/kWh, this represents $4,800–$11,200 in direct electricity cost reduction per year. However, the primary economic driver for ZW-13/30 selection is typically the 石油関連消耗品の排除と下流の油除去装置の回避 that would be mandatory with lubricated alternatives. At 3.00 MPa, the partial pressure of oil vapor is approximately 15 times higher than at 0.30 MPa, making downstream oil-filtration systems exponentially more expensive and less effective. The 超高圧窒素圧縮装置の総所有コスト is reduced by an estimated 25–35% over a 10-year operational life when oil-free operation is compared to lubricated systems with full downstream purification.

The absence of oil in the compression path is particularly critical at 3.00 MPa because oil contamination becomes highly concentrated and virtually impossible to remove to the levels required by food-grade, pharmaceutical, and semiconductor applications. The ZW-13/30’s native oil-free design eliminates this challenge entirely, providing guaranteed product purity without the complexity and cost of downstream purification trains.

カスタマイズおよびOEM対応

We offer comprehensive customization options to adapt the ZW-13/30 to specific site conditions, integration requirements, and end-user specifications:

  • スキッドマウント型ターンキーパッケージ: Pre-assembled compressor, motor, intercooler, aftercooler, high-pressure discharge piping, instrumentation, and control panel on a structural steel skid with integrated lifting lugs and anchor bolt templates. Factory pre-testing of all systems reduces commissioning time and risk.
  • 危険区域構成: ATEX Zone 2 and IECEx compliant motor and electrical enclosures for petrochemical installations. Integrated gas detection and automatic ventilation interlocks incorporated into the control system.
  • 高度なプロセス制御: Optional Siemens S7-1200 or Allen-Bradley CompactLogix PLC with 10-inch HMI touchscreen, remote monitoring via Modbus TCP/IP or OPC-UA, and seamless DCS/SCADA integration. High-pressure safety interlocks including automatic unload on overpressure, emergency isolation valves, and redundant pressure monitoring.
  • 環境保護: C5-M marine-grade coating systems for coastal installations; tropicalized electrical components for ambient temperatures up to 55°C; and IP54-rated acoustic enclosures reducing noise emission from 85 dB(A) to 72 dB(A) at 1 meter.
  • OEMおよびプライベートブランド: Custom paint colors, branded nameplates, and localized documentation packages for gas equipment distributors and system integrators. Technical manuals and maintenance procedures available in multiple languages.

カスタム構成は以下から入手可能です 最小注文数量:1個. Engineering review and proposal generation typically require 5–7 business days. Standard delivery time is 12–14 weeks; repeat orders are delivered in 8–10 weeks from order confirmation.

ZW-13/30 nitrogen compressor custom skid mounted high pressure package

Case Study: Industrial Gas Filling Station Upgrade

クライアント: A major industrial gas supplier in Malaysia operating a nitrogen cylinder filling station serving manufacturing, medical, and food processing customers

チャレンジ: The client’s existing oil-lubricated high-pressure compressor (European brand, 14 years in service) was experiencing progressive oil carryover into the nitrogen product stream. Oil contamination levels reached 2.2 mg/m³, far exceeding the 0.1 mg/m³ specification required by pharmaceutical and food-grade customers. The oil was also degrading the activated carbon purification beds in the filling manifold, requiring replacement every 5 months instead of the designed 18-month interval. Customer complaints were increasing, and regulatory inspections were becoming more frequent and demanding.

解決: 私たちは供給しました ZW-13/30 oil-free nitrogen compressor as the primary intermediate booster, configured on a custom skid with integrated intercooler, aftercooler, and a Siemens S7-1200 PLC control panel. The 3.00 MPa discharge pressure fed a downstream high-pressure filling compressor, reducing the overall compression ratio required of the filling stage. The oil-free design eliminated the need for activated carbon purification beds entirely. A 3 m³ surge vessel was installed upstream to buffer demand fluctuations from the filling manifold.

24か月後の定量的な結果:

  • 窒素油含有量: Reduced from 2.2 mg/m³ to <0.01 mg/m³ISO 8573-1クラス0を達成
  • Activated carbon bed replacement: 完全に排除された消耗品費を年間14兆12000円節約
  • Customer complaints: Zero since commissioning, with five new pharmaceutical contracts won
  • Filling compressor maintenance: Reduced by 35% due to lower inlet pressure ratio
  • Regulatory inspection results: Passed with zero findings in two consecutive audits
  • Payback period: 2.3 years based on cost savings and new contract revenue

“The ZW-13/30 has transformed our filling station from a quality risk into a competitive advantage. We now guarantee ISO 8573-1 Class 0 nitrogen to every customer, and we’ve won contracts that we couldn’t even bid on before. The oil-free design has eliminated our biggest operational headache and our customers have noticed the difference immediately.” — Operations Director, Industrial Gas Supplier

ZW-13/30 nitrogen compressor industrial gas filling station installation

よくある質問と選択ガイド

What is the expected service life of the ZW-13/30 under high-pressure operating conditions?

The ZW-13/30 is engineered for a minimum design life of 12 years (approximately 100,000 operating hours) in clean nitrogen service at high pressure. The cast-iron frame and forged steel crankshaft are rated for the full design life. PTFE piston rings and rider bands are the primary wear components, with replacement intervals of 3,000–5,000 hours under high-pressure conditions. Valve plate assemblies typically achieve 2,000–3,500 hours before requiring refurbishment due to the increased mechanical stress at 3.00 MPa.

Can the ZW-13/30 be used for direct cylinder filling to 15–20 MPa?

The ZW-13/30’s maximum discharge pressure is 3.00 MPaこれは、15~20 MPa の直接シリンダー充填には不十分です。しかし、優れた 中間ブースター in a staged compression system. By boosting nitrogen from 0.05–0.10 MPa to 3.00 MPa, the ZW-13/30 dramatically reduces the compression ratio required of the downstream high-pressure filling compressor, improving overall system efficiency and reducing wear on the expensive high-pressure stage. This staged approach is the recommended configuration for all cylinder filling applications.

Is the ZW-13/30 suitable for outdoor installation?

The standard ZW-13/30 is designed for 屋内設置 in a ventilated machinery room. For outdoor use, we offer an optional IP54防水筐体 with space heating (for -20°C climates), solar shields (for 55°C ambient), and forced ventilation. The acoustic enclosure option is highly recommended for outdoor installations to maintain noise compliance (75 dB(A) at property boundary).

How does the three-row design benefit high-pressure operation compared to two-row designs?

The three-row opposed-cylinder arrangement provides superior force balance compared to two-row designs, reducing vibration transmission by over 90% versus single-row equivalents. At 3.00 MPa, the peak gas forces on the pistons are substantially higher than at low pressure, making force balance critical for foundation design and adjacent equipment protection. The three-row design also distributes the compression work across more cylinders, reducing the thermal load per cylinder and improving overall thermodynamic efficiency. This mechanical advantage permits installation on a lighter foundation block and reduces the need for massive concrete inertia blocks, saving civil engineering costs. For a detailed comparison of compressor architectures, see our nitrogen compressor selection guide.

When should I avoid selecting the ZW-13/30?

The ZW-13/30 is NOT recommended for: (1) Discharge pressures above 3.50 MPa—consider our DW series or ZW multi-stage series for higher pressure requirements; (2) 容量要件が5 m³/分未満—smaller models in the ZW series offer better part-load efficiency and lower capital cost; (3) Applications where discharge pressure is consistently below 1.50 MPa—lower-pressure models such as the LW-52/8 or LW-40/4 offer significantly better specific power consumption and should be selected for low-pressure applications; (4) 定格容量35%以下の連続流量変調—piston compressors experience reduced efficiency at deep turndown; a dual-unit arrangement or VFD-equipped screw may be preferable for highly variable demand.

関連製品およびソリューション

DWシリーズ高圧窒素コンプレッサー

Designed for discharge pressures from 0.40 MPa to 2.00 MPa, the DW series covers nitrogen injection, high-pressure pipeline boosting, and chemical synthesis. Capacities from 2 to 130 m³/min with multi-stage configurations.

DWシリーズを探索する →

ZWシリーズ 多段式オイルフリーコンプレッサー

酸素、窒素、水素、および特殊ガス用の縦型多段式オイルフリーコンプレッサー。最大吐出圧力は9.00MPaで、超高圧ガス充填や化学プロセス用途に対応します。

ZWシリーズを探索する →

LWシリーズ大容量窒素コンプレッサー

極低温空気分離装置(ASU)のバックアップ、VPSA(真空圧力調整装置)の昇圧、および産業用パイプライン配管向けに設計された、高流量オイルフリーピストンコンプレッサー(20~130 m³/分)。吐出圧力は0.30~0.80 MPa。

LWシリーズを探索する →

当社の包括的な概要については、 工業用窒素圧縮機 オイルフリー酸素圧縮機、水素圧縮機、二酸化炭素圧縮機、および特注設計の特殊ガスソリューションを含む製品ポートフォリオの詳細については、当社のアプリケーションエンジニアリングチームにお問い合わせいただくか、オンライン製品カタログをご覧ください。

Ready to Upgrade Your High-Pressure Nitrogen System?

当社のアプリケーションエンジニアが、お客様の窒素流量要件、吸引条件、吐出圧力目標、およびシステム統合上の制約を評価するために待機しております。お問い合わせをいただいてから48時間以内に、無料の技術提案書、基礎レイアウト図、配管計装図(P&ID)、および詳細な総所有コスト(TCO)分析をご提供いたします。

メールアドレス: [email protected] 24時間以内に返信いたします