Kompresor Nitrogen ZW-3.1/5~20 – Booster N2 Bebas Oli Tekanan Variabel untuk Aplikasi Industri yang Fleksibel

Deskripsi

Kompresor Nitrogen ZW-3.1/5~20 – Booster N2 Bebas Oli Tekanan Variabel untuk Aplikasi Industri yang Fleksibel

Dirancang untuk menghasilkan 3,1 m³/menit pada rentang tekanan yang luas yaitu 0,50–2,00 MPa, ZW-3.1/5~20 adalah kompresor nitrogen piston bebas oli dua tahap, dua baris yang dirancang untuk pabrik percontohan, fasilitas R&D, dan proses industri skala kecil yang membutuhkan tekanan pelepasan yang dapat disesuaikan. Tidak ada kontaminasi pelumas, ukuran yang ringkas, dan dioptimalkan untuk pasokan nitrogen yang serbaguna.

 

Gambaran Umum Produk

Itu ZW-3.1/5~20 nitrogen compressor represents a uniquely versatile solution within our oil-free piston compressor family, distinguished by its variable discharge pressure capability spanning 0.50 MPa to 2.00 MPa. This pressure flexibility makes the ZW-3.1/5~20 ideally suited for pilot plant operations, research and development facilities, and small-scale industrial processes where nitrogen demand characteristics change frequently or where a single compressor must serve multiple applications with differing pressure requirements.

With a rated capacity of 3.1 m³/min at 0.50 MPa inlet pressure, this compact unit delivers oil-free nitrogen compression through a proprietary sistem ring piston dan sabuk penggerak komposit PTFE yang melumasi sendiri. The absence of hydrocarbon lubricants in the compression path ensures ISO 8573-1 Class 0 oil content certification natively, making the unit immediately suitable for laboratory-grade nitrogen, pharmaceutical process development, and electronics prototyping without additional downstream purification equipment.

The compressor follows a dua tahap, dua baris (二列二级) configuration with an exceptionally compact footprint of 2250 × 1296 × 2200 mm and a dry weight of only 2,60 ton. The two-row opposed-cylinder design inherently cancels first-order inertial forces, permitting installation on a modest foundation without specialized vibration isolation infrastructure. The standard 380V, 75 kW motor integrates directly into existing low-voltage industrial distribution systems, eliminating the need for medium-voltage switchgear.

ZW-3.1/5~20 nitrogen compressor compact two stage variable pressure design

Technical Specifications – ZW-3.1/5~20

Parameter Nilai Satuan
Model ZW-3.1/5~20
Pola Dua tahap, Dua baris (二列二级)
Kapasitas 3.1 (at 0.50 MPa inlet) m³/menit
Discharge Pressure Range 0.50 – 2.00 MPa
Ukuran Kompresor (P × L × T) 2250 × 1296 × 2200 mm
Berat 2.60 T
Kekuatan 75 kW
Voltase 380 V
Medium Gas Nitrogen (N₂)
Pelumasan Bebas minyak

* Capacity is rated at 0.50 MPa inlet pressure. Actual capacity varies with inlet pressure and discharge pressure settings. All specifications are rated at standard reference conditions (ISO 1217, Annex C). Actual performance may vary based on site altitude, ambient temperature, and operating conditions.

Fitur Utama & Keunggulan Teknik

1. Variable Discharge Pressure for Multi-Application Flexibility

The defining characteristic of the ZW-3.1/5~20 is its adjustable discharge pressure range from 0.50 MPa to 2.00 MPa. This versatility is achieved through a combination of adjustable suction valve unloaders, variable clearance pocket control, and a robust two-stage compression architecture that can accommodate a wide range of pressure ratios. For pilot plant operators and R&D facilities, this means a single compressor can serve multiple process requirements—low-pressure inerting at 0.50 MPa during one campaign, medium-pressure reactor blanketing at 1.20 MPa during another, and high-pressure gas transfer at 2.00 MPa during a third—without requiring separate compressor investments or time-consuming equipment changeovers.

2. Oil-Free PTFE Composite Sealing Technology

The ZW-3.1/5~20 employs a proprietary rakitan ring piston pelumas otomatis dan pita penggerak manufactured from high-performance PTFE composites reinforced with glass fiber and bronze particulates. These rings operate with a coefficient of friction below 0.08 without any external hydrocarbon lubrication, delivering Kandungan minyak ISO 8573-1 Kelas 0 in the compressed nitrogen stream. For research laboratories, pharmaceutical pilot plants, and electronics development facilities, this native oil-free certification eliminates the need for downstream oil-filtration equipment, reducing both capital expenditure and ongoing maintenance complexity. The PTFE formulation is specifically engineered for the variable thermal conditions associated with adjustable pressure operation.

3. Compact Two-Stage Architecture with Intercooling

Itu two-stage, two-row compression layout divides the pressure ratio between a low-pressure cylinder and a high-pressure cylinder, with an inter-stage shell-and-tube cooler removing the heat of compression. This staged approach is particularly critical for the ZW-3.1/5~20 given its wide pressure range, as it limits the maximum discharge temperature per stage even at the highest pressure setting (2.00 MPa). The intercooler maintains gas temperatures below 160°C across the full operating envelope, preserving PTFE ring integrity and extending valve plate service life. The two-row opposed-cylinder arrangement also provides inherent first-order force balance, reducing vibration transmission and permitting installation on a lighter foundation.

4. Standard 380V Direct Drive for Easy Integration

The ZW-3.1/5~20 is driven by a Motor induksi tiga fasa 75 kW, 380V, 50Hz conforming to IEC 60034-1 efficiency class IE3. The standard low-voltage configuration integrates directly into existing 380V industrial distribution panels without requiring medium-voltage infrastructure, step-down transformers, or specialized switchgear. This electrical simplicity is particularly advantageous for pilot plants and R&D facilities that may lack medium-voltage electrical infrastructure. The modest 75 kW power draw also minimizes demand charges and simplifies electrical permitting in facilities with limited power capacity.

ZW-3.1/5~20 nitrogen compressor general assembly compact variable pressure design

Skenario Aplikasi

Pilot Plant & Process Development

Chemical and pharmaceutical pilot plants frequently require nitrogen at varying pressures depending on the process campaign. The ZW-3.1/5~20 variable-pressure nitrogen compressor can supply low-pressure inerting (0.50–0.80 MPa) for reactor filling and emptying operations, medium-pressure blanketing (1.00–1.50 MPa) for stirred-tank reactors, and high-pressure gas transfer (1.80–2.00 MPa) for catalyst loading and filter press operations. This multi-pressure capability eliminates the need for multiple compressors or pressure-reducing stations, reducing both capital investment and plant footprint.

ZW-3.1/5~20 nitrogen compressor pilot plant process development application

Research & Development Laboratories

University research laboratories, government research institutes, and corporate R&D centers require versatile nitrogen supplies for diverse experimental programs. The ZW-3.1/5~20 can provide low-pressure nitrogen (0.50 MPa) for glove box inerting and Schlenk line operations, medium-pressure nitrogen (1.00–1.50 MPa) for high-pressure reaction vessels and autoclaves, and high-pressure nitrogen (2.00 MPa) for gas chromatography carrier gas and mass spectrometry ionization sources. The oil-free certification ensures that nitrogen purity meets the stringent requirements of analytical instrumentation without additional purification.

Small-Scale VPSA Nitrogen Boosting

Small VPSA nitrogen generators (5–15 Nm³/h capacity) produce nitrogen at near-atmospheric pressure. The ZW-3.1/5~20 boosts this low-pressure product to the pressure required by the specific application, with the flexibility to adjust output pressure as demand changes. This is particularly valuable for facilities that serve multiple nitrogen consumers with different pressure requirements, such as a combination of low-pressure storage tank blanketing and high-pressure process vessel inerting.

ZW-3.1/5~20 nitrogen compressor small scale VPSA boosting application

Electronics Prototyping & Semiconductor Development

Electronics prototyping facilities and semiconductor development labs require nitrogen for reflow oven atmosphere control, wire bonding inerting, and component storage dry cabinets. The ZW-3.1/5~20’s variable pressure capability allows it to serve both low-pressure reflow ovens (0.50–0.80 MPa) and high-pressure wire bonding equipment (1.50–2.00 MPa) from a single source. The oil-free design is absolutely critical in electronics applications because even trace oil contamination can cause solder joint defects, conformal coating adhesion failures, and contamination of sensitive optical and MEMS components.

Bahan & Konstruksi

The ZW-3.1/5~20 is constructed from materials selected for nitrogen compatibility, variable-pressure service, and long-term reliability:

Komponen Bahan Spesifikasi
Blok Silinder Besi Cor Abu-abu GG25 / HT250, integral cooling passages
Poros engkol Baja Paduan Tempa 42CrMo4, Q&T, seimbang secara dinamis
Cincin Piston Komposit PTFE-Kaca-Perunggu Self-lubricating, variable-pressure rated
Pita Rider Komposit PTFE Panduan piston, anti-gores
Pelat Katup Baja tahan karat SS316, pegas cincin konsentris
Intercooler Cangkang Baja Karbon / Tabung SS304 ASME VIII Div.1, uji hidrostatis 1,5×
Pendingin udara Cangkang Baja Karbon / Tabung SS304 Finned tube, 32°C cooling water rated
Rangka Dasar Baja Struktural Welded, vibration-damped mounting

All pressure-bearing components conform to ASME BPVC Bagian VIII Divisi 1 or Chinese GB 150 standards. Weld joints undergo 100% radiographic inspection (RT), and each pressure vessel is hydrostatically tested at 1.5× MAWP for a minimum 30-minute hold period.

ZW-3.1/5~20 nitrogen compressor factory precision machining

Panduan Pemasangan & Pemeliharaan

Persyaratan Pondasi & Spasial

The ZW-3.1/5~20 weighs 2.60 tonnes and features a compact vertical design with a low center of gravity. A bantalan beton bertulang seberat 4–5 ton is sufficient for stable operation, mounted on standard elastomeric vibration isolators (natural frequency 8–12 Hz). The two-row opposed-cylinder arrangement inherently cancels first-order inertial forces, minimizing vibration transmission. Required clearances: 1.0 m on the non-drive side for valve access, 0.8 m on the drive side for motor maintenance, and 1.5 m overhead for routine service. The compact footprint allows installation in existing machinery rooms, containerized units, or mobile skids.

Spesifikasi Air Pendingin

Kebutuhan air pendingin kira-kira 15 m³/jam at an inlet temperature not exceeding 32°C. The water circuit supplies the cylinder jackets and intercooler in parallel. Water quality: pH 6.5–8.5, total hardness < 300 mg/L as CaCO₃, chloride < 50 mg/L, suspended solids < 30 mg/L. For installations without reliable municipal water, a compact closed-loop cooling tower with a 0.5 m³ buffer tank is recommended.

Maintenance Intervals

Selang Item Layanan Tindakan yang Diperlukan
Sehari-hari Pemeriksaan Visual & Operasional Inspect for leaks, abnormal noise, cooling water flow
250 jam Inspeksi Pelat Katup Check for carbon deposits, spring fatigue, or cracking
1.000 jam Penilaian Keausan Ring Piston Measure groove clearance; replace if > 0.20 mm
4.000 jam Layanan Menengah Ganti ring piston, sabuk penggerak, dan rakitan katup.
8.000 jam Perbaikan Besar-besaran Inspect crankshaft, measure bearing clearances

The oil-free design eliminates oil changes, filter replacements, and separator maintenance. The only consumable wear items are the Ring piston PTFE dan sabuk penggerak, typically achieving 4,000–6,000 hours under clean nitrogen conditions.

ZW-3.1/5~20 nitrogen compressor workshop assembly

Sertifikasi Kepatuhan & Keselamatan

The ZW-3.1/5~20 meets the following international standards:

Peralatan Tekanan
ASME BPVC Bagian VIII Div.1, GB 150-2011, PED 2014/68/EU Modul A
Keselamatan Listrik & Mesin
IEC 60034-1 (efisiensi IE3), IEC 60204-1, ISO 12100
Sertifikasi Bebas Minyak
ISO 8573-1 Kelas 0 (Kandungan Minyak), diuji oleh TÜV Rheinland
Kualitas & Lingkungan
ISO 9001:2015, ISO 14001:2015
⚠️ Pemberitahuan Keselamatan

Nitrogen is an odorless asphyxiant gas. All installations must include continuous oxygen monitoring in the compressor room. Ventilation must maintain oxygen above 19.5% per OSHA 29 CFR 1910.146. Alarm at 19.5% O₂, hard shutdown at 18.0% O₂. Personnel entry requires portable O₂ monitors and buddy system.

ZW-3.1/5~20 nitrogen compressor ISO certification

Analisis Kinerja & Efisiensi

The ZW-3.1/5~20 achieves a specific power consumption that varies with discharge pressure setting, ranging from approximately 24.2 kW/m³/min at 0.50 MPa ke 24.2 kW/m³/min at 2.00 MPa (based on 75 kW power draw and 3.1 m³/min capacity). While the specific power is higher than larger compressors due to reduced scale efficiency, the ZW-3.1/5~20’s primary value proposition is its versatility—the ability to replace multiple single-pressure compressors with one adjustable unit.

For facilities that would otherwise require separate compressors for low-pressure (0.50 MPa), medium-pressure (1.20 MPa), and high-pressure (2.00 MPa) service, the ZW-3.1/5~20 eliminates the capital cost of two additional compressors, the associated piping and instrumentation, and the floor space they would occupy. The total cost of ownership for flexible nitrogen compression is often lower than maintaining multiple single-purpose compressors, even when accounting for the slightly higher specific power consumption.

Kemampuan Kustomisasi & OEM

We provide flexible customization for the ZW-3.1/5~20:

  • Paket yang Dipasang di Atas Rangka: Pre-assembled compressor, motor, cooler, and controls on a structural steel skid with forklift pockets. Reduces field installation to electrical and cooling water connections only.
  • Unit Trailer Bergerak: Mounted on a road-legal trailer with integrated diesel generator and cooling system for fully mobile nitrogen supply at construction sites and remote locations.
  • PLC & Pemantauan Jarak Jauh: Optional Siemens LOGO! or S7-1200 PLC with HMI touchscreen, Ethernet connectivity, and SMS/email alarms. Modbus TCP/IP compatible for SCADA integration.
  • Ruang Kedap Suara: Compact IP54-rated enclosure reducing noise from 82 dB(A) to 68 dB(A) at 1 meter, suitable for laboratory and office-adjacent installations.
  • OEM & Private Label: Custom paint, branded nameplates, and localized documentation for distributors and system integrators.

Custom configurations available from MOQ 1 unit. Engineering proposals within 3–5 business days. Standard delivery 10–12 weeks; expedited 8 weeks available.

ZW-3.1/5~20 nitrogen compressor custom skid mounted mobile unit

Case Study: Pharmaceutical Pilot Plant Nitrogen Supply

Klien: A pharmaceutical development company in Singapore

Tantangan: The pilot plant operated three separate nitrogen compressors: a 0.50 MPa unit for reactor inerting, a 1.20 MPa unit for filter press operations, and a 2.00 MPa unit for catalyst loading. The three compressors occupied excessive floor space, required separate maintenance schedules, and had a combined annual maintenance cost of $32,000. Oil contamination from one of the lubricated compressors had compromised a batch of active pharmaceutical ingredient (API), resulting in a $150,000 loss.

Larutan: Kami menyediakan ZW-3.1/5~20 oil-free variable-pressure nitrogen compressor on a compact skid with integrated controls. The unit replaced all three existing compressors, freeing 12 m² of floor space and eliminating oil contamination risk entirely. Pressure adjustment is performed via the HMI panel, allowing operators to select the required pressure for each process campaign.

Hasil Setelah 18 Bulan:

  • Floor space: Freed 12 m² by consolidating three compressors into one
  • Biaya perawatan tahunan: Reduced by 55% ($32,000 to $14,400)
  • Oil contamination incidents: Nol since commissioning
  • Process flexibility: Pressure changes completed in under 5 minutes via HMI, versus 2-hour compressor swapovers previously
  • Periode pengembalian modal: 1.8 years based on maintenance savings and avoided contamination losses

“The ZW-3.1/5~20 has simplified our nitrogen supply dramatically. One compressor does the work of three, and we never have to worry about oil contamination compromising our API batches. The ability to change pressure from the control panel is a game-changer for our pilot plant operations.” — Process Engineering Manager

ZW-3.1/5~20 nitrogen compressor pharmaceutical pilot plant installation

FAQ & Panduan Seleksi

How is the discharge pressure adjusted on the ZW-3.1/5~20?

Discharge pressure is adjusted through a combination of suction valve unloaders Dan variable clearance pocket control. The operator sets the target pressure via the control panel HMI, and the PLC automatically adjusts the compressor’s operating parameters to achieve the desired output. Pressure changes typically take 3–5 minutes to stabilize. The system includes safety interlocks to prevent operation outside the rated pressure envelope.

Does capacity change with discharge pressure setting?

Yes. The rated capacity of 3.1 m³/min is at 0.50 MPa discharge pressure. As discharge pressure increases, volumetric efficiency decreases due to higher clearance volume re-expansion. At 2.00 MPa discharge pressure, the effective capacity is approximately 2.4–2.6 m³/min. This capacity reduction is a characteristic of all piston compressors and should be factored into system sizing calculations. For applications requiring maximum capacity at high pressure, consider our DW series fixed-pressure high-capacity models.

What is the expected service life of the ZW-3.1/5~20?

The ZW-3.1/5~20 is designed for a masa pakai minimum 15 tahun (approximately 120,000 operating hours) in clean nitrogen service. The cast-iron frame and forged steel crankshaft are rated for the full design life. PTFE piston rings and rider bands are the primary wear items, with replacement intervals of 4,000–6,000 hours. Valve plate assemblies typically last 2,500–4,000 hours.

Is the ZW-3.1/5~20 suitable for outdoor installation?

The standard unit is designed for instalasi dalam ruangan. For outdoor use, we offer an optional Kotak pelindung tahan cuaca IP54 with space heating, solar shields, and forced ventilation. The acoustic enclosure option is recommended for outdoor installations to maintain noise compliance.

When should I choose a fixed-pressure compressor instead of the ZW-3.1/5~20?

Choose a fixed-pressure model if: (1) Your application requires a single, constant pressure and never changes—fixed-pressure compressors offer slightly better efficiency at their design point; (2) You require capacity above 5 m³/min—the ZW-3.1/5~20 is optimized for small-scale applications; (3) You need discharge pressure above 2.00 MPa—consider our DW series or ZW multi-stage models for higher pressure requirements. For a detailed comparison, see our panduan pemilihan kompresor nitrogen.

Produk & Solusi Terkait

Kompresor Nitrogen Kapasitas Besar Seri LW

High-flow oil-free piston compressors (20–130 m³/min) for cryogenic ASU backup, VPSA boosting, and industrial pipeline distribution. Fixed discharge pressures from 0.30 to 0.80 MPa.

Jelajahi Seri LW →

Kompresor Nitrogen Tekanan Tinggi Seri DW

Fixed-pressure oil-free compressors (0.40–2.00 MPa) for nitrogen injection, pipeline boosting, and chemical synthesis. Capacities from 2 to 130 m³/min.

Jelajahi Seri DW →

Kompresor Tekanan Menengah Seri MW

Medium-pressure oil-free compressors (1.0–4.0 MPa) for nitrogen recycle, gas liquefaction, and process gas compression in petrochemical operations.

Jelajahi Seri MW →

Untuk gambaran lengkap mengenai kami kompresor nitrogen industri portfolio, contact our engineering team or browse our online catalog.

Need a Flexible Nitrogen Compression Solution?

Our application engineers are ready to evaluate your variable pressure requirements, flow demands, and integration constraints. We provide complimentary technical proposals, layout drawings, and TCO analyses within 48 hours.

E-mail: [email protected] | Tanggapan dalam 24 jam