China Manufacturer Direct Selling Two-Stage Low-Pressure Screw Air Compressor Does Not Need Excitation Current for Food and Beverage 12v air compressor

Solution Description

NO Power
(kW)
Force
(Mpa)
Volumetric stream
 (m3/min)
Exhaust outlet measurement
 GBT7306 (m) GBT9119(flange)
Excess weight
(kg)
Dimensions
 (L x W x H mm)
UDT55-seven 55 .seven 12.00 DN80 2520 2300x1290x1820(A)
UDT55-8 .8 11.00
UDT75-seven 75 .7 fifteen.twenty DN80 2530 2300x1290x1820(A)
UDT75-eight .eight fifteen.twenty
UDT75-10 one. thirteen.30
UDT75-12.5 1.25 12.00
UDT90-7 90 .seven twenty.50 DN80 3640
3500
2530
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT90-eight .8 19.fifty
UDT90-ten one. fifteen.twenty
UDT90-twelve.five 1.twenty five fourteen.thirty
UDT110-seven 110 .7 24.50 DN80 3640
3900
2680
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT110-8 .8 23.forty
UDT110-10 one. 20.30
UDT110-12.five 1.25 fifteen.twenty
UDT132-seven 132 .7 29.fifty DN80 4200
4000
3050x1850x2120(A)
2850x1850x2120(W)
UDT132-8 .8 27.00
UDT132-ten one. 23.00
UDT160-7 160 .seven 34.00 DN80 4400
4200
3050x1850x2120(A)
2850x1850x2120(W)
UDT160-8 .eight 33.00
UDT160-ten one. 27.00
UDT185-seven 185 .seven 39.00 DN100 5600
5300
3600x1850x2150(A)
3050x1850x2150(W)
UDT185-eight .eight 38.00
UDT185-10 1. 32.50
UDT200-seven 200 .seven forty three.50 DN125 7350
6800
4200x2150x2250(A)
3400x2150x2250(W)
UDT200-8 .eight 41.00
UDT220-7 220 .seven fifty.00 DN125 7450
6900
4200x2150x2250(A)
3400x2150x2250(W)
UDT220-8 .8 forty six.00
UDT220-10 1. 41.00
UDT250-seven 250 .seven fifty three.00 DN125 7550
7000
4200x2150x2250(A)
3400x2150x2250(W)
UDT250-8 .8 fifty.00
UDT250-10 1. forty six.00
UDT280-7 280 .seven 59 DN125 8550
8200
4200x2150x2250(A)
3400x2150x2250(W)
UDT280-eight .8 56
UDT280-ten 1. fifty
UDT315-seven 315 .7 65 DN125 10000
 9120
5000x2150x2300(A)
3850x2150x2300(W)
UDT315-eight .8 sixty one
UDT315-10 one. fifty three
UDT355-seven 355 .seven 69.five DN125 11200
9200
11825
15710
5000x2150x2300(A)
3850x2150x2300(W)
6000x2150x2450(A)
4650x2150x2450(W)
UDT355-8 .8 sixty nine.five
UDT355-ten one. 61
UDT355-seven .seven seventy eight DN150
UDT355-8 .eight 76.5
UDT355-ten one. 67.five
UDT400-7 400 .7 85 DN150 11985
1571
6000x2150x2450(A)
4650x2150x2450(W)
UDT400-eight .eight 84
UDT400-ten one. seventy seven
UDT450-7 450 .seven ninety four.five DN150 12015
10440
6000x2150x2450(A)
4650x2150x2450(W)
UDT450-eight .8 ninety three
UDT450-ten 1. 84
UDT500-seven 500 .seven 104 DN150 12045
1571
6000x2150x2450(A)
4650x2150x2450(W)
UDT500-8 .eight 103
UDT500-10 one. 93
UDT560-ten 560 one. 103 DN150 12095
10520
6000x2150x2450(A)
4650x2150x2450(W)

FAQ
Q: How about our following-revenue services?
A: Emails or calls for feedbacks in 2 months interval.

Q:What trade terms do we offer?
A: Trade expression :CIF ,CFR ,FOB,Ex-Performs .  

Q: What sort of settlement currency do we offer you?
A: We do any variety of forex this sort of as US greenback, euro, RMB, and so forth.

Q: How long is the delivery time of our item?
A: Our regular delivery time is thirty times right after affirmation buy & acquiring recipets for common compressors, for the other non normal prerequisite will be mentioned situation by circumstance.

Q: How to put in our compressor?
A: Installation guidance and on-web site commissioning presented by educated specialists or neighborhood authorised service crew.

Q: What’s the Min. Buy need ? 
A: Our Min. Order quantity is 1pc.

 

To Be Negotiated 1 Piece
(Min. Order)

###

After-sales Service: Standard Warranty
Warranty: 1 Year
Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: None

###

Customization:

###

NO Power
(kW)
Pressure
(Mpa)
Volumetric flow
 (m3/min)
Exhaust outlet size
 GBT7306 (m) GBT9119(flange)
Weight
(kg)
Size
 (L x W x H mm)
UDT55-7 55 0.7 12.00 DN80 2520 2300x1290x1820(A)
UDT55-8 0.8 11.00
UDT75-7 75 0.7 15.20 DN80 2530 2300x1290x1820(A)
UDT75-8 0.8 15.20
UDT75-10 1.0 13.30
UDT75-12.5 1.25 12.00
UDT90-7 90 0.7 20.50 DN80 3640
3500
2530
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT90-8 0.8 19.50
UDT90-10 1.0 15.20
UDT90-12.5 1.25 14.30
UDT110-7 110 0.7 24.50 DN80 3640
3900
2680
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT110-8 0.8 23.40
UDT110-10 1.0 20.30
UDT110-12.5 1.25 15.20
UDT132-7 132 0.7 29.50 DN80 4200
4000
3050x1850x2120(A)
2850x1850x2120(W)
UDT132-8 0.8 27.00
UDT132-10 1.0 23.00
UDT160-7 160 0.7 34.00 DN80 4400
4200
3050x1850x2120(A)
2850x1850x2120(W)
UDT160-8 0.8 33.00
UDT160-10 1.0 27.00
UDT185-7 185 0.7 39.00 DN100 5600
5300
3600x1850x2150(A)
3050x1850x2150(W)
UDT185-8 0.8 38.00
UDT185-10 1.0 32.50
UDT200-7 200 0.7 43.50 DN125 7350
6800
4200x2150x2250(A)
3400x2150x2250(W)
UDT200-8 0.8 41.00
UDT220-7 220 0.7 50.00 DN125 7450
6900
4200x2150x2250(A)
3400x2150x2250(W)
UDT220-8 0.8 46.00
UDT220-10 1.0 41.00
UDT250-7 250 0.7 53.00 DN125 7550
7000
4200x2150x2250(A)
3400x2150x2250(W)
UDT250-8 0.8 50.00
UDT250-10 1.0 46.00
UDT280-7 280 0.7 59 DN125 8550
8200
4200x2150x2250(A)
3400x2150x2250(W)
UDT280-8 0.8 56
UDT280-10 1.0 50
UDT315-7 315 0.7 65 DN125 10000
 9120
5000x2150x2300(A)
3850x2150x2300(W)
UDT315-8 0.8 61
UDT315-10 1.0 53
UDT355-7 355 0.7 69.5 DN125 11200
9200
11825
10250
5000x2150x2300(A)
3850x2150x2300(W)
6000x2150x2450(A)
4650x2150x2450(W)
UDT355-8 0.8 69.5
UDT355-10 1.0 61
UDT355-7 0.7 78 DN150
UDT355-8 0.8 76.5
UDT355-10 1.0 67.5
UDT400-7 400 0.7 85 DN150 11985
10410
6000x2150x2450(A)
4650x2150x2450(W)
UDT400-8 0.8 84
UDT400-10 1.0 77
UDT450-7 450 0.7 94.5 DN150 12015
10440
6000x2150x2450(A)
4650x2150x2450(W)
UDT450-8 0.8 93
UDT450-10 1.0 84
UDT500-7 500 0.7 104 DN150 12045
10470
6000x2150x2450(A)
4650x2150x2450(W)
UDT500-8 0.8 103
UDT500-10 1.0 93
UDT560-10 560 1.0 103 DN150 12095
10520
6000x2150x2450(A)
4650x2150x2450(W)
To Be Negotiated 1 Piece
(Min. Order)

###

After-sales Service: Standard Warranty
Warranty: 1 Year
Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: None

###

Customization:

###

NO Power
(kW)
Pressure
(Mpa)
Volumetric flow
 (m3/min)
Exhaust outlet size
 GBT7306 (m) GBT9119(flange)
Weight
(kg)
Size
 (L x W x H mm)
UDT55-7 55 0.7 12.00 DN80 2520 2300x1290x1820(A)
UDT55-8 0.8 11.00
UDT75-7 75 0.7 15.20 DN80 2530 2300x1290x1820(A)
UDT75-8 0.8 15.20
UDT75-10 1.0 13.30
UDT75-12.5 1.25 12.00
UDT90-7 90 0.7 20.50 DN80 3640
3500
2530
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT90-8 0.8 19.50
UDT90-10 1.0 15.20
UDT90-12.5 1.25 14.30
UDT110-7 110 0.7 24.50 DN80 3640
3900
2680
2600x1700x2090(A)
2850x1850x2120(W)
2300x1290x1820(A)
UDT110-8 0.8 23.40
UDT110-10 1.0 20.30
UDT110-12.5 1.25 15.20
UDT132-7 132 0.7 29.50 DN80 4200
4000
3050x1850x2120(A)
2850x1850x2120(W)
UDT132-8 0.8 27.00
UDT132-10 1.0 23.00
UDT160-7 160 0.7 34.00 DN80 4400
4200
3050x1850x2120(A)
2850x1850x2120(W)
UDT160-8 0.8 33.00
UDT160-10 1.0 27.00
UDT185-7 185 0.7 39.00 DN100 5600
5300
3600x1850x2150(A)
3050x1850x2150(W)
UDT185-8 0.8 38.00
UDT185-10 1.0 32.50
UDT200-7 200 0.7 43.50 DN125 7350
6800
4200x2150x2250(A)
3400x2150x2250(W)
UDT200-8 0.8 41.00
UDT220-7 220 0.7 50.00 DN125 7450
6900
4200x2150x2250(A)
3400x2150x2250(W)
UDT220-8 0.8 46.00
UDT220-10 1.0 41.00
UDT250-7 250 0.7 53.00 DN125 7550
7000
4200x2150x2250(A)
3400x2150x2250(W)
UDT250-8 0.8 50.00
UDT250-10 1.0 46.00
UDT280-7 280 0.7 59 DN125 8550
8200
4200x2150x2250(A)
3400x2150x2250(W)
UDT280-8 0.8 56
UDT280-10 1.0 50
UDT315-7 315 0.7 65 DN125 10000
 9120
5000x2150x2300(A)
3850x2150x2300(W)
UDT315-8 0.8 61
UDT315-10 1.0 53
UDT355-7 355 0.7 69.5 DN125 11200
9200
11825
10250
5000x2150x2300(A)
3850x2150x2300(W)
6000x2150x2450(A)
4650x2150x2450(W)
UDT355-8 0.8 69.5
UDT355-10 1.0 61
UDT355-7 0.7 78 DN150
UDT355-8 0.8 76.5
UDT355-10 1.0 67.5
UDT400-7 400 0.7 85 DN150 11985
10410
6000x2150x2450(A)
4650x2150x2450(W)
UDT400-8 0.8 84
UDT400-10 1.0 77
UDT450-7 450 0.7 94.5 DN150 12015
10440
6000x2150x2450(A)
4650x2150x2450(W)
UDT450-8 0.8 93
UDT450-10 1.0 84
UDT500-7 500 0.7 104 DN150 12045
10470
6000x2150x2450(A)
4650x2150x2450(W)
UDT500-8 0.8 103
UDT500-10 1.0 93
UDT560-10 560 1.0 103 DN150 12095
10520
6000x2150x2450(A)
4650x2150x2450(W)

How to Choose the Right Air Compressor

An air compressor uses pressurized air to power a variety of tools. They are most commonly used to power nailers and impact wrenches. Other popular uses for air compressors include paint sprayers and impact wrenches. While all air compressors have the same basic construction, their specialty differs. Ultimately, their differences come down to the amount of air they can push. Read on for information on each type of air compressor. These tools are great for many different purposes, and choosing the right air compressor depends on your specific needs.
air-compressor

Electric motor

While purchasing an electric motor for air compressor, compatibility is a key factor. Not all motors work with the same type of air compressor, so it’s important to check the manufacturer’s instructions before purchasing. By doing this, you can avoid wasting money on an incompatible motor. Another important consideration is speed. A motor’s speed is its rate of rotation, measured in revolutions per minute. It is critical that you purchase a motor with sufficient speed to meet the needs of your air compressor.
Typically, an electric motor for air compressor is 1.5 hp. It is ideal for use with medical equipment and metal-cutting machines. It also performs well under continuous operation and offers a high efficiency and energy-saving performance. Moreover, it features an attractive price, making it a good choice for a wide range of applications. If you are looking for a motor for an air compressor, look no further than a ZYS series.
A motor’s protection class indicates how the motor will operate. Protection classes are specified by the IEC 60034-5. These are stated with two digits and represent the protection against solid objects and water. For example, an IP23 rating means that the motor will be protected from solid objects, while IP54 means that it will protect from dust and water sprayed from all directions. It is vital to choose a motor with the correct protection class for your air compressor.
When choosing an electric motor, you should consider whether it’s compatible with the brand of air compressor. Some may be compatible, while others may require advanced electronics skills to repair. However, most air compressors are covered by warranty, so it’s important to check with the manufacturer if the warranty is still in effect before you spend a dime on a replacement. The motor should be replaced if it has failed to perform as designed.
air-compressor

Oil bath

Air compressors require proper lubrication to function efficiently. The piston must draw air with minimal friction. Depending on their design, air compressors can either be oil-lubricated or oil-free. The former uses oil to reduce piston friction, while the latter splashes it on the cylinder bearings and walls. Such air compressors are commonly known as oil-flooded air compressors. In order to keep their oil baths clean, they are recommended for use in locations with high dust levels.

Start/stop control

An air compressor can be controlled by a start/stop control. This type of control sends a signal to the main motor that activates the compressor when the demand for air falls below a preset limit. This control strategy is effective for smaller air compressors and can be useful for reducing energy costs. Start/stop control is most effective in applications where air pressure does not change frequently and where the compressor is not required to run continuously.
To troubleshoot this problem, you need to check the power supply of your compressor. To check the supply side, use a voltage monitor to determine if power is flowing to the compressor. Ensure that the power supply to the compressor is steady and stable at all times. If it fluctuates, the compressor may not start or stop as expected. If you cannot find the problem with the air compressor power supply, it may be time to replace it.
In addition to the start/stop control, you may want to purchase additional air receivers for your air compressor. These can increase the capacity of air stored and reduce the number of times it starts and stops. Another way to decrease the number of starts per hour is to add more air receivers. Then, you can adjust the control to match your requirements. You can also install a pressure gauge that monitors the compressor’s performance.
Start/stop control for air compressors can be complex, but the basic components are relatively easy to understand. One way to test them is to turn the compressor on or off. It is usually located on the exterior of the motor. If you’re unsure of the location of these components, check the capacitors and make sure that the air compressor is not running while you’re not using it. If it does, try to remove the capacitor.
Variable displacement control is another way to adjust the amount of air flowing into the compressor. By controlling the amount of air, the control can delay the use of additional compressors until more required air is available. In addition to this, the device can also monitor the energy used in the compressor. This control method can result in substantial energy savings. You can even save on the amount of electricity by using variable displacement control. It is essential for efficient compressed air systems.
air-compressor

Variable speed drive

A VFD, or variable frequency drive, is a type of electric motor that adjusts its speed to match the demand for air. It is an efficient way to reduce energy costs and improve system reliability. In fact, studies have shown that a 20% reduction in motor speed can save up to 50% of energy. In addition, a VFD can monitor additional variables such as compressor oil pressure and motor temperature. By eliminating manual checks, a VFD will improve the performance of the application and reduce operating costs.
In addition to reducing energy costs, variable-speed drives also increase productivity. A variable-speed air compressor reduces the risk of system leaks by 30 percent. It also reduces the risk of system leaks by reducing pressure in the system. Because of these advantages, many governments are promoting this technology in their industries. Many even offer incentives to help companies upgrade to variable-speed drives. Therefore, the variable-speed drive can benefit many air compressor installations.
One major benefit of a variable-speed drive is its ability to optimize energy use. Variable frequency drives are able to ramp up and down to match the demand for air. The goal is to optimize the pressure and flow in the system so that the best “dead band” occurs between forty percent and eighty percent of full load. A variable-speed compressor will also increase energy efficiency because of its programmability.
A variable-speed air compressor can also be used to control the amount of air that is compressed by the system. This feature adjusts the frequency of power supplied to the motor based on the demand. If the demand for air is low, the frequency of the motor will reduce to save energy. On the other hand, if there is an excess demand for air, the variable-speed compressor will increase its speed. In addition, this type of air compressor is more efficient than its fixed-speed counterpart.
A VFD has many benefits for compressed air systems. First, it helps stabilize the pressure in the pipe network, thereby reducing the power losses due to upstream pressure. It also helps reduce the power consumption caused by fluctuations in upward pressure. Its benefits are also far-reaching. And as long as the air pressure and air supply is properly sized, a VFD will help optimize the efficiency of compressed air systems.

China Manufacturer Direct Selling Two-Stage Low-Pressure Screw Air Compressor Does Not Need Excitation Current for Food and Beverage     12v air compressorChina Manufacturer Direct Selling Two-Stage Low-Pressure Screw Air Compressor Does Not Need Excitation Current for Food and Beverage     12v air compressor
editor by czh 2023-01-06