LW-18/12 Nitrogen Compressor – Medium-Flow High-Pressure Oil-Free N2 Booster for Demanding Industrial Applications

الوصف

LW-18/12 Nitrogen Compressor – Medium-Flow High-Pressure Oil-Free N2 Booster for Demanding Industrial Applications

Engineered to deliver 18 m³/min at 1.20 MPa discharge pressure, the LW-18/12 is a two-stage, two-row oil-free piston nitrogen compressor purpose-built for high-pressure nitrogen injection, chemical synthesis, and specialized industrial gas distribution where elevated pressure and uncompromised purity converge. Zero lubricant contamination, continuous-duty rated, and optimized for 24/7 operation in the most demanding environments.

LW-18/12 nitrogen compressor high pressure oil-free industrial unit

نظرة عامة على المنتج

ال LW-18/12 nitrogen compressor occupies a specialized niche within our oil-free piston compressor portfolio, engineered for applications where elevated discharge pressure takes precedence over absolute flow volume. With a rated capacity of 18 m³/min واستثنائي 1.20 MPa discharge pressure, this unit bridges the gap between standard medium-pressure nitrogen boosters and the ultra-high-pressure domain of multi-stage specialty gas compressors.

What distinguishes the LW-18/12 from conventional high-pressure alternatives is its آلية ضغط خالية تمامًا من الزيت utilizing self-lubricating PTFE composite piston rings and rider bands. This design philosophy eliminates any possibility of hydrocarbon contamination in the nitrogen product stream, making the unit immediately suitable for high-purity chemical synthesis, pharmaceutical-grade nitrogen injection, and electronics-grade process gas supply without requiring additional downstream purification stages. The oil-free certification is particularly critical at 1.20 MPa because oil contamination at elevated pressure becomes exponentially more difficult and expensive to remove.

إنه two-stage, two-row (二列二级) configuration is thermodynamically optimized for the high pressure ratio demanded by 1.20 MPa discharge. The staged compression with inter-stage cooling limits the discharge temperature of each cylinder to safe operating envelopes, preserving the integrity of the PTFE sealing elements and extending valve service life. The robust construction—2632 × 1550 × 2332 mm و 3.00 tonnes—reflects the heavy-duty engineering required to sustain high-pressure operation while maintaining the compact footprint characteristic of the LW series.

LW-18/12 nitrogen compressor high pressure two stage piston design

Technical Specifications – LW-18/12

المعلمة قيمة وحدة
نموذج LW-18/12
نمط مرحلتين، صفين (二列二级)
سعة 18 م³/دقيقة
ضغط التفريغ 1.20 ميجا باسكال
حجم الضاغط (الطول × العرض × الارتفاع) 2632 × 1550 × 2332 مم
وزن 3.00 ت
قوة 160 كيلوواط
الجهد االكهربى 380 V
وسط غازي النيتروجين (N₂)
تشحيم خالٍ من الزيوت

* جميع المواصفات مصنفة وفقًا لظروف مرجعية قياسية (ISO 1217، الملحق ج). قد يختلف الأداء الفعلي بناءً على ارتفاع الموقع ودرجة الحرارة المحيطة وظروف المدخل.

الميزات الرئيسية والمزايا الهندسية

1. تقنية منع التسرب عالية الضغط الخالية من الزيت باستخدام مادة PTFE

The LW-18/12 employs a specialized نظام حلقات المكبس ذاتية التشحيم ونظام حزام التوجيه manufactured from high-performance PTFE composites reinforced with glass fiber, bronze particulates, and molybdenum disulfide. This advanced formulation achieves a coefficient of friction below 0.06 without any external hydrocarbon lubrication, completely eliminating oil vapor carryover risk even at the elevated temperatures associated with 1.20 MPa discharge pressure. For operators in chemical synthesis and pharmaceutical manufacturing, this delivers native ISO 8573-1 Class 0 compliance without the capital expense, energy penalty, or maintenance burden of high-pressure oil-removal systems that would otherwise be mandatory at this pressure level.

2. Two-Stage Compression for Extreme Pressure Ratios

ال two-stage compression architecture of the LW-18/12 is thermodynamically critical for achieving the 1.20 MPa discharge pressure from typical nitrogen inlet conditions (0.05–0.10 MPa). By dividing the extreme pressure ratio between a low-pressure cylinder and a high-pressure cylinder, the compressor limits the discharge temperature of each stage to below 160°C. A high-efficiency shell-and-tube intercooler between stages removes the heat of compression, preventing thermal degradation of the PTFE sealing elements and extending valve plate service life by approximately 50% compared to single-stage designs attempting equivalent pressure ratios. The staged approach also improves volumetric efficiency, delivering more nitrogen per unit of power consumed.

3. Reinforced High-Pressure Cylinder Construction

The high-pressure cylinder of the LW-18/12 is constructed from GG30 gray cast iron with thicker wall sections and reinforced head bolts compared to standard-pressure models. The cylinder head features a multi-layer gasket system with stainless steel fire rings to prevent blow-by at 1.20 MPa. The valve cage assemblies are fabricated from SS316L forged bar stock rather than castings, eliminating porosity risks that could lead to catastrophic failure under high cyclic pressure loading. All high-pressure components are subjected to 100% magnetic particle inspection (MT) and ultrasonic testing (UT) to detect subsurface defects before assembly.

4. محرك صناعي قياسي 380 فولت

The LW-18/12 is driven by a 160 kW, 380V, 50Hz three-phase induction motor rated to IEC 60034-1 efficiency class IE3. The standard low-voltage configuration integrates directly into existing 380V industrial distribution panels without requiring medium-voltage infrastructure, making this model accessible to facilities that may not have 6kV or 10kV bus systems. The 160 kW power rating is optimized for the 18 m³/min flow and 1.20 MPa pressure, achieving a favorable balance between capital cost and operating efficiency for medium-flow high-pressure applications.

LW-18/12 nitrogen compressor general assembly high pressure design

سيناريوهات التطبيق

High-Pressure Chemical Synthesis & Reactor Inerting

In chemical manufacturing facilities, the LW-18/12 provides high-pressure nitrogen for reactor inerting, catalyst bed preservation, and emergency nitrogen injection into process vessels operating at elevated pressures. The 1.20 MPa discharge pressure is sufficient to overcome the operating pressure of typical chemical reactors and distillation columns, allowing direct nitrogen injection without intermediate pressure boosting. The oil-free design is absolutely critical in chemical synthesis because even trace oil contamination can poison precious metal catalysts, initiate unwanted side reactions, or contaminate high-purity product streams. The 18 m³/min capacity supports multiple reactor systems operating in parallel within a medium-scale chemical plant.

LW-18/12 nitrogen compressor chemical synthesis reactor inerting application

Pharmaceutical High-Pressure Nitrogen Injection

تتطلب مرافق تصنيع الأدوية النيتروجين عالي النقاء لـ sterile vessel inerting, lyophilization (freeze-drying) chamber pressurization, and aseptic filling line purging. The LW-18/12 high-pressure nitrogen compressor delivers the 1.20 MPa pressure required for lyophilization chamber operation while maintaining ISO 8573-1 Class 0 oil-free certification. The 18 m³/min capacity can simultaneously supply multiple lyophilizers, sterile holding tanks, and filling lines within a medium-scale pharmaceutical facility. The oil-free design eliminates the risk of product contamination that could trigger FDA regulatory action or batch rejection.

Electronics High-Pressure Process Gas Supply

In semiconductor fabrication and flat-panel display manufacturing, nitrogen is used for high-pressure wafer handling, chamber purge, and chemical vapor deposition (CVD) process support. The LW-18/12’s 1.20 MPa discharge pressure is sufficient for high-purity nitrogen distribution to process tools operating at elevated pressures. The oil-free certification is non-negotiable in electronics manufacturing because even sub-ppm oil contamination can cause wafer defects, reduce device yield, and compromise the performance of sensitive optical coatings. The 18 m³/min capacity supports a cluster of process tools within a cleanroom bay.

LW-18/12 nitrogen compressor electronics high pressure process gas supply

Nitrogen Cylinder Filling & Gas Distribution

Industrial gas distributors and cylinder filling stations require high-pressure nitrogen compressors to fill standard industrial gas cylinders (typically 15 MPa at 20°C) from lower-pressure sources such as liquid nitrogen vaporizers or membrane generators. The LW-18/12 serves as the first-stage booster in a multi-stage filling system, compressing nitrogen from 0.10 MPa to 1.20 MPa for subsequent high-pressure compression to cylinder pressure. The oil-free design ensures that filled cylinders meet the purity specifications of medical, food-grade, and electronic-grade nitrogen markets without requiring cylinder evacuation and re-purging due to oil contamination.

المواد والإنشاءات

The LW-18/12 is constructed from premium materials specifically selected for high-pressure nitrogen service, corrosion resistance, and extended operational life under demanding conditions:

عنصر مادة مواصفة
كتلة الأسطوانات (LP) حديد الزهر الرمادي GG25 / HT250، سمك جدار قياسي
كتلة الأسطوانات (HP) حديد الزهر الرمادي GG30 / HT300, reinforced wall, thicker head
عمود المرفق فولاذ سبيكي مطروق 42CrMo4, Q&T, ISO 1940 G2.5 dynamically balanced
حلقات المكبس PTFE-Glass-Bronze-MoS₂ Composite Self-lubricating, high-temp rated to 180°C
أساور رايدر مركب PTFE Piston guidance, anti-scuffing, wear rate <0.04 mm/1000h
Valve Cages (HP) SS316L Forged Bar 100% MT/UT inspected, zero porosity tolerance
صفائح الصمامات الفولاذ المقاوم للصدأ SS316L, concentric ring spring-loaded design
مبرد داخلي غلاف من الفولاذ الكربوني / أنابيب من الفولاذ المقاوم للصدأ 316 ASME VIII القسم 1، اختبار هيدروديناميكي 1.5×، تثبيت لمدة 30 دقيقة
مبرد لاحق غلاف من الفولاذ الكربوني / أنابيب من الفولاذ المقاوم للصدأ 316 Finned tube design, 32°C cooling water rated
High-Pressure Gaskets Spiral Wound SS316/Graphite Fire rings, ASME B16.20 compliant

تم تصميم وتصنيع جميع المكونات التي تتحمل الضغط وفقًا لمعايير صارمة. ASME BPVC القسم الثامن القسم 1 or Chinese GB 150 standards. Every weld joint undergoes 100% radiographic inspection (RT) per ASME Section V, Article 2, and each completed pressure vessel is subjected to a hydrostatic pressure test at 1.5 times the maximum allowable working pressure (MAWP) for a minimum hold period of 30 minutes. High-pressure components receive additional magnetic particle inspection (MT) and ultrasonic testing (UT) to ensure zero defect tolerance.

LW-18/12 nitrogen compressor factory precision machining high pressure components

إرشادات التركيب والصيانة

متطلبات الأساس والهيكل

The LW-18/12 has a dry weight of 3.00 tonnes and a center of gravity approximately 800 mm above the baseplate. The two-row opposed-cylinder design provides inherent force balance, allowing installation on a قاعدة خرسانية مسلحة بوزن 5-6 أطنان. The pad should be mounted on elastomeric vibration isolators (natural frequency 8–12 Hz) to prevent vibration transmission to sensitive adjacent equipment such as analytical instruments or precision manufacturing tools. Minimum clearance requirements: 1.2 m on the non-drive side for valve access, 1.0 m on the drive side for motor maintenance, and 1.5 m overhead for crane access during major overhauls.

تصميم نظام مياه التبريد

يبلغ الطلب على مياه التبريد ما يقارب 22 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit supplies the cylinder jackets, intercooler, and aftercooler in parallel branches. Water quality specifications: pH 6.5–8.5, total dissolved solids < 500 mg/L, chloride content < 50 mg/L (to prevent SS316 tube corrosion in the high-pressure coolers), suspended solids < 30 mg/L, and total hardness < 300 mg/L as CaCO₃. For sites with marginal water quality, a closed-loop cooling tower with side-stream filtration and chemical treatment is strongly recommended to prevent scale formation and corrosion in the high-pressure heat exchangers.

جدول الصيانة الوقائية

فاصلة بند الخدمة الإجراء المطلوب
يوميًا التفتيش التشغيلي Check vibration levels, abnormal noise, cooling water flow, discharge temperature and pressure
250 ساعة فحص صفيحة الصمام Remove and inspect suction/discharge valves for carbon deposits, spring fatigue, or cracking
1000 ساعة تقييم تآكل حلقات المكبس قم بقياس خلوص أخاديد الحلقات؛ واستبدل الحلقات إذا تجاوز الخلوص 0.20 مم
4000 ساعة إصلاح متوسط استبدل جميع حلقات المكابس، وأشرطة التوجيه، ومجموعات صفيحة الصمامات.
8000 ساعة إصلاح شامل رئيسي افحص محاور عمود المرفق، وقم بقياس خلوص المحامل الرئيسية، واستبدل المحامل إذا كان الخلوص أكبر من 0.08 مم

The oil-free design of the LW-18/12 dramatically simplifies maintenance compared to lubricated alternatives. There are no oil changes to schedule, no lubricating oil samples to analyze, no oil filter elements to replace, and no oil separator cartridges to monitor. The primary consumable wear items are the حلقات مكابس PTFE وأحزمة تثبيت, which typically achieve 3,500–5,500 hours of service life under clean nitrogen conditions at 1.20 MPa. The high-pressure valve assemblies require more frequent inspection than low-pressure models due to the increased mechanical stress on valve plates and springs.

LW-18/12 nitrogen compressor workshop assembly and quality inspection

شهادات الامتثال والسلامة

The LW-18/12 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:

Pressure Equipment Directive
ASME BPVC القسم الثامن Div.1، GB 150-2011، PED 2014/68/EU الوحدة A
السلامة الكهربائية والميكانيكية
معايير السلامة الميكانيكية IEC 60034-1 (كفاءة IE3)، IEC 60204-1، ISO 12100
Oil-Free Air Quality
ISO 8573-1 الفئة 0 (محتوى الزيت)، تم اختباره بشكل مستقل بواسطة TÜV Rheinland
الجودة والبيئة
ISO 9001:2015 (Quality Management), ISO 14001:2015 (Environmental Management)
⚠️ Critical Safety Advisory

Nitrogen is classified as a simple asphyxiant gas. At 1.20 MPa discharge pressure, the LW-18/12 stores significant potential energy in the compressed gas, and any leakage can rapidly displace oxygen in enclosed spaces. All installations must incorporate continuous oxygen deficiency monitoring in the compressor room and all downstream areas where high-pressure nitrogen is distributed. Ventilation systems must be engineered to maintain ambient oxygen concentrations above 19.5% volume per OSHA 29 CFR 1910.146. Emergency shutdown interlocks should activate at 19.5% O₂ (alarm) and trigger automatic compressor isolation at 18.0% O₂ (hard shutdown). High-pressure relief valves must be installed downstream of the compressor and sized per ASME BPVC Section VIII. Personnel entry procedures into enclosed compressor rooms must include portable oxygen monitors and a buddy-system protocol.

LW-18/12 nitrogen compressor ISO certification and compliance documentation

تحليل الأداء والكفاءة

The LW-18/12 achieves a specific power consumption of approximately 8.89 kW per m³/min of nitrogen delivered at 1.20 MPa discharge pressure. This specific power is higher than lower-pressure models due to the thermodynamic penalty associated with elevated pressure ratios, but it remains competitive within the high-pressure oil-free piston compressor segment. For context, oil-lubricated screw compressors operating at equivalent pressure ratios typically consume 9.5–10.5 kW/m³/min, while diaphragm compressors (often selected for oil-free high-pressure service) can exceed 12 kW/m³/min.

Over a standard 8,000-hour annual operating schedule, the LW-18/12’s efficiency advantage versus less efficient alternatives yields approximately 72,000–144,000 kWh of annual energy savings. At an average industrial electricity tariff of $0.08/kWh, this represents $5,760–$11,520 in direct operating cost reduction per year. However, the primary economic driver for LW-18/12 selection is typically the elimination of oil-related consumables and the avoidance of high-pressure oil-removal equipment rather than marginal energy savings.

At 1.20 MPa, the cost and complexity of downstream oil-removal equipment becomes prohibitive. A typical oil-lubricated compressor at this pressure would require multiple stages of coalescing filtration, activated carbon adsorption, and continuous oil monitoring instrumentation, collectively consuming 5–8% of the compressor’s power output and requiring annual maintenance expenditure of $8,000–$15,000. The LW-18/12’s oil-free design removes this parasitic load and maintenance burden entirely, delivering a significantly lower total cost of ownership for high-pressure nitrogen compression.

إمكانيات التخصيص وتصنيع المعدات الأصلية

We provide comprehensive customization options to adapt the LW-18/12 to specific high-pressure application requirements, site conditions, and integration constraints:

  • حزم جاهزة للتسليم مثبتة على قاعدة انزلاقية: The compressor, motor, intercooler, aftercooler, high-pressure instrumentation, and control panel are pre-assembled on a structural steel skid with integrated lifting lugs and anchor bolt templates. Factory pre-testing of all high-pressure systems reduces field commissioning time and minimizes startup risks.
  • تكوينات المناطق الخطرة: ATEX Zone 2 and IECEx compliant motor and electrical enclosures are available for installations in chemical processing facilities where explosive atmospheres may occasionally be present. Integrated gas detection and automatic ventilation interlocks can be incorporated into the control system.
  • التحكم المتقدم في العمليات: Optional Siemens S7-1200 or Allen-Bradley CompactLogix PLC with 10-inch HMI touchscreen, remote monitoring via Modbus TCP/IP or OPC-UA, and seamless integration with plant DCS/SCADA systems. Automatic load/unload control and pressure regulation optimize operation for variable demand profiles.
  • High-Pressure Safety Systems: Redundant high-pressure relief valves, rupture disc assemblies, and automatic isolation valves can be integrated to meet specific safety integrity level (SIL) requirements. Pressure transmitters with 4–20 mA output provide continuous monitoring of discharge pressure.
  • حماية البيئة: C5-M marine-grade coating systems for coastal installations; tropicalized electrical components for ambient temperatures up to 55°C; and IP54-rated acoustic enclosures reducing noise from 84 dB(A) to 70 dB(A) at 1 meter.
  • تصنيع المعدات الأصلية والعلامات التجارية الخاصة: Custom paint colors, branded nameplates, and localized documentation packages for gas equipment distributors and system integrators serving specialized industrial markets.

تتوفر التكوينات المخصصة من الحد الأدنى للطلب: وحدة واحدة. Engineering review and proposal generation typically require 5–7 business days. Standard delivery time is 12–14 weeks; repeat orders are delivered in 8–10 weeks from order confirmation.

LW-18/12 nitrogen compressor custom skid mounted high pressure package

Case Study: Pharmaceutical Lyophilization Nitrogen Supply Upgrade

عميل: A pharmaceutical manufacturing facility in Europe specializing in injectable biologics and vaccines

تحدي: The facility’s lyophilization (freeze-drying) chambers required high-pressure nitrogen at 1.00–1.20 MPa for chamber pressurization and stopper insertion. The existing supply relied on high-pressure nitrogen cylinders delivered weekly, with costs exceeding €180,000/year and frequent supply disruptions during winter weather. The facility also faced regulatory pressure to reduce its carbon footprint from cylinder transportation and vaporization losses.

حل: We supplied an LW-18/12 oil-free nitrogen compressor paired with a small VPSA nitrogen generator (99.9% purity, 20 m³/min) on a common skid. The LW-18/12 compresses the VPSA product from 0.08 MPa to 1.20 MPa, feeding the lyophilization chamber nitrogen header directly. The oil-free design ensured compliance with EU GMP Annex 1 (sterile manufacturing) requirements for oil-free process gases. A 2 m³ high-pressure buffer vessel was installed downstream to absorb demand spikes during chamber cycling.

Quantified Results After 18 Months:

  • Nitrogen supply cost: تم تخفيضها بمقدار 58% (€180,000 to €75,600/year) versus cylinder supply
  • Supply reliability: 100% on-site generation, zero weather-related disruptions
  • نقاء النيتروجين: باستمرار >99.9% with oil content <0.01 mg/m³, exceeding GMP requirements
  • Carbon footprint: تم تخفيضها بمقدار 65% through elimination of cylinder transportation and vaporization losses
  • Maintenance: One scheduled service per year (4,000-hour interval), versus weekly cylinder handling
  • فترة الاسترداد: 2.1 years based on gas cost savings alone

“The LW-18/12 has eliminated our dependency on cylinder deliveries and given us complete control over our nitrogen supply. The oil-free certification was critical for our GMP compliance, and the cost savings have exceeded our projections. Our sustainability team is particularly pleased with the carbon footprint reduction.” — Director of Engineering, Pharmaceutical Manufacturing

LW-18/12 nitrogen compressor pharmaceutical lyophilization installation case study

الأسئلة الشائعة ودليل الاختيار

What is the expected service life of the LW-18/12 under high-pressure operating conditions?

The LW-18/12 is engineered for a الحد الأدنى للعمر التصميمي 15 عامًا (approximately 120,000 operating hours) in clean nitrogen service. The cast-iron frame and forged steel crankshaft are rated for the full design life. The PTFE piston rings and rider bands are the primary wear components, with a typical replacement interval of 3,500–5,500 hours at 1.20 MPa—slightly shorter than lower-pressure models due to the increased mechanical stress. Valve plate assemblies typically achieve 2,000–3,500 hours before requiring refurbishment under high-pressure conditions.

Can the LW-18/12 handle the pulsating inlet pressure from a VPSA nitrogen generator?

Yes. The LW-18/12 can accommodate inlet pressure variations from 0.03 MPa to 0.12 MPa without performance degradation. For VPSA applications with significant pressure pulsation, we strongly recommend installing a minimum 1.5 m³ surge vessel upstream of the compressor suction to dampen cyclic fluctuations and protect the high-pressure valves from hydraulic shock. An optional pulsation dampener can be fitted for severe pulsation conditions.

Is the LW-18/12 suitable for outdoor installation?

The standard LW-18/12 is designed for تركيب داخلي in a ventilated machinery room. For outdoor installation, we offer an optional غلاف مقاوم للعوامل الجوية بمعيار IP54 with space heating (for -20°C climates), solar radiation shields (for 55°C ambient), and forced ventilation. The acoustic enclosure option is recommended for outdoor installations to maintain noise compliance (typically 75 dB(A) at property boundary).

How does the LW-18/12 compare to diaphragm compressors for high-pressure oil-free nitrogen service?

Diaphragm compressors offer absolute oil-free assurance and are suitable for ultra-high pressures (>10 MPa), but they suffer from significantly lower efficiency (typically 10–15 kW/m³/min), limited capacity (usually <5 m³/min), and high maintenance costs due to frequent diaphragm replacement. The LW-18/12 achieves superior efficiency (8.89 kW/m³/min), higher capacity (18 m³/min), and lower maintenance burden while still delivering native ISO 8573-1 Class 0 certification. For applications at 1.20 MPa, the LW-18/12 offers a compelling balance of performance, reliability, and total cost of ownership. For a detailed comparison, refer to our تحليل عائد الاستثمار لضاغط النيتروجين.

Under what circumstances should I avoid selecting the LW-18/12?

The LW-18/12 is NOT the optimal choice for: (1) Discharge pressures exceeding 1.50 MPa—for higher pressure requirements, consider our DW series (up to 2.00 MPa) or ZW multi-stage series (up to 9.00 MPa); (2) Capacity requirements above 25 m³/min— توفر طرازات سلسلة LW الأكبر حجماً كفاءة أفضل في الحجم؛ (3) Applications requiring discharge pressures below 0.60 MPa—lower-pressure models in the LW series offer significantly better efficiency at reduced pressure ratios; (4) تعديل التدفق المستمر أقل من 40% من السعة المقدرةتكون ضواغط المكابس أقل كفاءة عند التخفيضات الكبيرة.

المنتجات والحلول ذات الصلة

ضواغط النيتروجين ذات السعة الكبيرة من سلسلة LW

ضواغط مكبسية عالية التدفق وخالية من الزيت (20-130 م³/دقيقة) لتوفير الطاقة الاحتياطية لوحدات فصل الهواء المبردة، وتعزيز ضغط الهواء المتغير الضغط، وتوزيع خطوط الأنابيب الصناعية. ضغوط التفريغ من 0.30 إلى 0.80 ميجا باسكال.

استكشف سلسلة LW →

ضواغط النيتروجين عالية الضغط من سلسلة DW

Designed for discharge pressures from 0.40 MPa to 2.00 MPa, covering nitrogen injection, high-pressure pipeline boosting, and chemical synthesis. Capacities from 2 to 130 m³/min.

استكشف سلسلة DW →

ضواغط سلسلة ZW متعددة المراحل خالية من الزيت

Vertical, multi-stage oil-free compressors for oxygen, nitrogen, hydrogen, and specialty gases. Discharge pressures up to 9.00 MPa for ultra-high-pressure gas filling and chemical process applications.

استكشف سلسلة ZW →

للحصول على نظرة عامة شاملة عن ضاغط نيتروجين صناعي للاطلاع على محفظتنا، بما في ذلك ضواغط الأكسجين الخالية من الزيت، وضواغط الهيدروجين، وضواغط ثاني أكسيد الكربون، وحلول الغازات المتخصصة المصممة حسب الطلب، يرجى الاتصال بفريق هندسة التطبيقات لدينا أو تصفح كتالوج منتجاتنا عبر الإنترنت.

هل أنت مستعد لترقية نظام النيتروجين عالي الضغط الخاص بك؟

مهندسونا المتخصصون في التطبيقات على أهبة الاستعداد لتقييم متطلبات تدفق النيتروجين، وظروف السحب، وأهداف ضغط التفريغ، وقيود التكامل. نقدم عروضًا فنية مجانية، ورسومات تخطيطية للأساسات، ومخططات الأنابيب والأجهزة (P&IDs)، وتحليلات تفصيلية للتكلفة الإجمالية للملكية (TCO) خلال 48 ساعة من استلام استفسارك.

بريد إلكتروني: [email protected] الرد خلال 24 ساعة