{"id":559,"date":"2026-07-20T06:08:30","date_gmt":"2026-07-20T06:08:30","guid":{"rendered":"https:\/\/n2-compressor.com\/?post_type=product&#038;p=559"},"modified":"2026-08-13T05:56:41","modified_gmt":"2026-08-13T05:56:41","slug":"dw-120-8-nitrogen-compressor","status":"publish","type":"product","link":"https:\/\/n2-compressor.com\/fa\/product\/dw-120-8-nitrogen-compressor\/","title":{"rendered":"\u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 DW-120\/8 \u2013 \u062a\u0642\u0648\u06cc\u062a\u200c\u06a9\u0646\u0646\u062f\u0647 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646 \u0628\u0627 \u0638\u0631\u0641\u06cc\u062a \u0641\u0648\u0642\u200c\u0627\u0644\u0639\u0627\u062f\u0647 \u0628\u0627\u0644\u0627 \u0628\u0631\u0627\u06cc \u0632\u06cc\u0631\u0633\u0627\u062e\u062a\u200c\u0647\u0627\u06cc \u06af\u0627\u0632 \u0635\u0646\u0639\u062a\u06cc \u0645\u0648\u0631\u062f \u0646\u06cc\u0627\u0632"},"content":{"rendered":"<div style=\"max-width: 1200px; margin: 0 auto; padding: 20px 15px; font-family: Arial,Helvetica,sans-serif; color: #1a1a1a; line-height: 1.7; word-break: break-word;\">\n<p><!-- Hero Section --><\/p>\n<div style=\"background: linear-gradient(135deg,#0a2442 0%,#1a3a5c 100%); padding: 60px 20px 50px; border-radius: 0; margin-bottom: 40px; text-align: center;\">\n<h1 style=\"font-size: clamp(1.8rem,4vw,2.8rem); color: #ffffff; margin: 0 0 15px; font-weight: bold; line-height: 1.2;\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 DW-120\/8 \u2013 \u062a\u0642\u0648\u06cc\u062a\u200c\u06a9\u0646\u0646\u062f\u0647 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646 \u0628\u0627 \u0638\u0631\u0641\u06cc\u062a \u0641\u0648\u0642\u200c\u0627\u0644\u0639\u0627\u062f\u0647 \u0628\u0627\u0644\u0627 \u0628\u0631\u0627\u06cc \u0632\u06cc\u0631\u0633\u0627\u062e\u062a\u200c\u0647\u0627\u06cc \u06af\u0627\u0632 \u0635\u0646\u0639\u062a\u06cc \u0645\u0648\u0631\u062f \u0646\u06cc\u0627\u0632<\/h1>\n<p style=\"font-size: clamp(1rem,2.5vw,1.2rem); color: #d6dce4; margin: 0 0 25px; max-width: 900px; margin-left: auto; margin-right: auto;\">Engineered to deliver an exceptional 120 m\u00b3\/min at 0.80 MPa discharge pressure, the DW-120\/8 is a two-stage, two-row oil-free piston nitrogen compressor purpose-built for mega-scale cryogenic air separation, high-pressure VPSA booster stations, and extensive petrochemical pipeline distribution networks. Zero lubricant contamination, continuous-duty rated, and optimized for 24\/7 operation at the highest industrial throughput levels.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"><a style=\"display: inline-block; padding: 14px 32px; background: #ff6b35; color: #ffffff; text-decoration: none; border-radius: 4px; font-weight: bold; font-size: 1rem; transition: opacity 0.3s;\" href=\"mailto:sales@n2-compressor.com\">\u062f\u0631\u062e\u0648\u0627\u0633\u062a \u0642\u06cc\u0645\u062a<\/a><br \/>\n<a style=\"display: inline-block; padding: 14px 32px; background: transparent; color: #ff6b35; text-decoration: none; border-radius: 4px; font-weight: bold; font-size: 1rem; border: 2px solid #ff6b35; transition: all 0.3s;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u0645\u0634\u0627\u0647\u062f\u0647 \u0633\u0631\u06cc \u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc N2<\/a><\/div>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 30px auto 0; border-radius: 4px; box-shadow: 0 8px 24px rgba(0,0,0,0.3);\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-0-5.Nitrogen-compressor-DW.jpg\" alt=\"DW-120\/8 nitrogen compressor ultra high capacity oil-free industrial unit\" \/><\/p>\n<\/div>\n<p><!-- Product Overview --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0646\u0645\u0627\u06cc \u06a9\u0644\u06cc \u0645\u062d\u0635\u0648\u0644<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The <strong>DW-120\/8 nitrogen compressor<\/strong> represents the pinnacle of our oil-free piston compressor engineering, occupying the ultra-high-capacity segment of our industrial nitrogen booster portfolio. With an extraordinary rated capacity of <strong>120 m\u00b3\/min<\/strong> and a robust <strong>\u0641\u0634\u0627\u0631 \u062a\u062e\u0644\u06cc\u0647 0.80 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644<\/strong>\u0627\u06cc\u0646 \u0648\u0627\u062d\u062f \u0628\u0647 \u06af\u0648\u0646\u0647\u200c\u0627\u06cc \u0637\u0631\u0627\u062d\u06cc \u0634\u062f\u0647 \u0627\u0633\u062a \u06a9\u0647 \u0628\u062a\u0648\u0627\u0646\u062f \u0633\u062e\u062a\u200c\u062a\u0631\u06cc\u0646 \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u062a\u0648\u0632\u06cc\u0639 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0631\u0627 \u062f\u0631 \u0632\u06cc\u0631\u0633\u0627\u062e\u062a\u200c\u0647\u0627\u06cc \u06af\u0627\u0632 \u0635\u0646\u0639\u062a\u06cc \u062f\u0631 \u0645\u0642\u06cc\u0627\u0633 \u0628\u0632\u0631\u06af \u062f\u0631 \u0633\u0631\u0627\u0633\u0631 \u062c\u0647\u0627\u0646 \u0628\u0631\u0622\u0648\u0631\u062f\u0647 \u06a9\u0646\u062f.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">What distinguishes the DW-120\/8 from all conventional alternatives is its <strong>\u0645\u0633\u06cc\u0631 \u0641\u0634\u0631\u062f\u0647\u200c\u0633\u0627\u0632\u06cc \u06a9\u0627\u0645\u0644\u0627\u064b \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646<\/strong> utilizing self-lubricating PTFE composite piston rings and rider bands. These advanced sealing elements operate without any hydrocarbon lubricants, ensuring the nitrogen product stream remains entirely free of oil contamination. This intrinsic oil-free characteristic delivers <strong>\u06af\u0648\u0627\u0647\u06cc\u0646\u0627\u0645\u0647 ISO 8573-1 \u06a9\u0644\u0627\u0633 0<\/strong> natively, eliminating the capital expenditure, maintenance burden, and energy penalty of downstream oil-removal filtration systems. For operators in food processing, pharmaceutical manufacturing, semiconductor fabrication, and petrochemical processing, this native purity is non-negotiable.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">\u0645\u0639\u0645\u0627\u0631\u06cc \u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0627\u0632 \u06cc\u06a9 <strong>\u062f\u0648 \u0645\u0631\u062d\u0644\u0647 \u0627\u06cc\u060c \u062f\u0648 \u0631\u062f\u06cc\u0641\u06cc (\u4e8c\u5217\u4e8c\u7ea7)<\/strong> configuration that optimally distributes the substantial pressure ratio across two compression cylinders. This staged approach is essential for managing the thermal loads associated with compressing 120 m\u00b3\/min to 0.80 MPa while preserving the integrity of the PTFE sealing elements. Each stage features a high-efficiency intercooler, ensuring gas temperatures remain within safe operating envelopes even during sustained maximum-capacity operation. The massive cast-iron frame and dynamically balanced forged steel crankshaft are rated for a minimum service life of <strong>\u06f1\u06f2\u06f0\u060c\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a<\/strong> \u062a\u062d\u062a \u067e\u0631\u0648\u062a\u06a9\u0644\u200c\u0647\u0627\u06cc \u062f\u0642\u06cc\u0642 \u0646\u06af\u0647\u062f\u0627\u0631\u06cc.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-22.-ZW-30-7-12-Nitrogen-Recycle-Compressor-Compressor.webp\" alt=\"DW-120\/8 nitrogen compressor high capacity two stage piston design\" \/><\/p>\n<\/div>\n<p><!-- Technical Specifications --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">Technical Specifications \u2013 DW-120\/8<\/h2>\n<div style=\"overflow-x: auto; margin-bottom: 15px;\">\n<table style=\"width: 100%; min-width: 600px; border-collapse: collapse; font-size: clamp(0.85rem,2vw,1rem);\">\n<thead>\n<tr style=\"background: #0a2442; color: #ffffff;\">\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u067e\u0627\u0631\u0627\u0645\u062a\u0631<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0627\u0631\u0632\u0634<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0648\u0627\u062d\u062f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u062f\u0644<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">\u062f\u0648\u06cc\u0686\u0647 \u0648\u0644\u0647-\u06f1\u06f2\u06f0\/\u06f8<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u2013<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0627\u0644\u06af\u0648<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">\u062f\u0648 \u0645\u0631\u062d\u0644\u0647 \u0627\u06cc\u060c \u062f\u0648 \u0631\u062f\u06cc\u0641\u06cc (\u4e8c\u5217\u4e8c\u7ea7)<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u2013<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0638\u0631\u0641\u06cc\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">120<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u062f\u0631 \u062f\u0642\u06cc\u0642\u0647<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0634\u0627\u0631 \u062a\u062e\u0644\u06cc\u0647<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">0.80<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0627\u0646\u062f\u0627\u0632\u0647 \u06a9\u0645\u067e\u0631\u0633\u0648\u0631 (\u0637\u0648\u0644 \u00d7 \u0639\u0631\u0636 \u00d7 \u0627\u0631\u062a\u0641\u0627\u0639)<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">5800 \u00d7 3518 \u00d7 2535<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u06cc\u0644\u06cc\u200c\u0645\u062a\u0631<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0648\u0632\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">15.00<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062a\u06cc<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0642\u062f\u0631\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">710<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06a9\u06cc\u0644\u0648\u0648\u0627\u062a<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0648\u0644\u062a\u0627\u0698<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">\u06f6 \u0647\u0632\u0627\u0631 \u06cc\u0627 \u06f1\u06f0 \u0647\u0632\u0627\u0631<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u067e\u0646\u062c\u0645<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06af\u0627\u0632 \u0645\u062a\u0648\u0633\u0637<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">\u0646\u06cc\u062a\u0631\u0648\u0698\u0646 (N\u2082)<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u2013<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0631\u0648\u0627\u0646\u06a9\u0627\u0631\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4; font-weight: 600;\">\u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: clamp(0.9rem,2vw,1rem); color: #666; margin: 0;\"><em>* \u062a\u0645\u0627\u0645 \u0645\u0634\u062e\u0635\u0627\u062a \u062f\u0631 \u0634\u0631\u0627\u06cc\u0637 \u0645\u0631\u062c\u0639 \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f (ISO 1217\u060c \u067e\u06cc\u0648\u0633\u062a C) \u0631\u062a\u0628\u0647\u200c\u0628\u0646\u062f\u06cc \u0634\u062f\u0647\u200c\u0627\u0646\u062f. \u0639\u0645\u0644\u06a9\u0631\u062f \u0648\u0627\u0642\u0639\u06cc \u0645\u0645\u06a9\u0646 \u0627\u0633\u062a \u0628\u0631 \u0627\u0633\u0627\u0633 \u0627\u0631\u062a\u0641\u0627\u0639 \u0645\u062d\u0644\u060c \u062f\u0645\u0627\u06cc \u0645\u062d\u06cc\u0637 \u0648 \u0634\u0631\u0627\u06cc\u0637 \u0648\u0631\u0648\u062f\u06cc \u0645\u062a\u0641\u0627\u0648\u062a \u0628\u0627\u0634\u062f.<\/em><\/p>\n<\/div>\n<p><!-- Key Features & Engineering Advantages --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0648\u06cc\u0698\u06af\u06cc\u200c\u0647\u0627\u06cc \u06a9\u0644\u06cc\u062f\u06cc \u0648 \u0645\u0632\u0627\u06cc\u0627\u06cc \u0645\u0647\u0646\u062f\u0633\u06cc<\/h2>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u06f1. \u0641\u0634\u0631\u062f\u0647\u200c\u0633\u0627\u0632\u06cc \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646 \u0628\u0627 \u0638\u0631\u0641\u06cc\u062a \u0641\u0648\u0642\u200c\u0627\u0644\u0639\u0627\u062f\u0647 \u0628\u0627\u0644\u0627<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 employs a proprietary <strong>\u0633\u06cc\u0633\u062a\u0645 \u0631\u06cc\u0646\u06af \u067e\u06cc\u0633\u062a\u0648\u0646 \u0648 \u0628\u0627\u0646\u062f \u0631\u0627\u062f\u06cc\u0627\u0644 \u062e\u0648\u062f \u0631\u0648\u0627\u0646 \u06a9\u0646\u0646\u062f\u0647<\/strong> manufactured from high-performance PTFE composites reinforced with glass fiber and bronze particulates. This advanced material formulation achieves a coefficient of friction below 0.06 without any external hydrocarbon lubrication, completely eliminating the risk of oil vapor carryover into the nitrogen product stream. At 120 m\u00b3\/min capacity, even trace oil contamination would represent a massive cumulative contamination burden\u2014making the DW-120\/8\u2019s native oil-free design absolutely critical. For industrial gas operators, this delivers <strong>\u0627\u0646\u0637\u0628\u0627\u0642 \u0628\u0627 \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f ISO 8573-1 \u06a9\u0644\u0627\u0633 0<\/strong> without the capital cost, maintenance burden, or energy penalty of downstream oil-filtration equipment that would be required for a lubricated compressor of this scale.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u06f2. \u0628\u0647\u06cc\u0646\u0647\u200c\u0633\u0627\u0632\u06cc \u062a\u0631\u0645\u0648\u062f\u06cc\u0646\u0627\u0645\u06cc\u06a9\u06cc \u062f\u0648 \u0645\u0631\u062d\u0644\u0647\u200c\u0627\u06cc \u0628\u0631\u0627\u06cc \u0641\u0634\u0627\u0631 \u0628\u0627\u0644\u0627<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The <strong>\u0645\u0639\u0645\u0627\u0631\u06cc \u0641\u0634\u0631\u062f\u0647\u200c\u0633\u0627\u0632\u06cc \u062f\u0648 \u0645\u0631\u062d\u0644\u0647\u200c\u0627\u06cc<\/strong> of the DW-120\/8 is thermodynamically optimized for the demanding 0.80 MPa discharge pressure target while managing the enormous flow volume of 120 m\u00b3\/min. By dividing the overall pressure ratio between a low-pressure cylinder and a high-pressure cylinder, the compressor achieves a significantly lower mean effective temperature per stage. A dedicated high-capacity shell-and-tube intercooler between stages removes the substantial heat of compression, maintaining discharge temperatures below 155\u00b0C even at maximum continuous load. This thermal management is essential for preserving PTFE ring integrity at this scale and extends valve plate service life by approximately 40% compared to single-stage designs operating at equivalent pressure ratios.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u06f3. \u0642\u0627\u0628 \u0686\u062f\u0646\u06cc \u0639\u0638\u06cc\u0645 \u0628\u0627 \u062a\u0639\u0627\u062f\u0644 \u0646\u06cc\u0631\u0648\u06cc \u0628\u0631\u062a\u0631<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">\u0642\u0627\u0628 \u0627\u0635\u0644\u06cc \u0627\u0632 \u0631\u06cc\u062e\u062a\u0647 \u06af\u0631\u06cc \u0633\u0627\u062e\u062a\u0647 \u0634\u062f\u0647 \u0627\u0633\u062a <strong>\u0686\u062f\u0646 \u062e\u0627\u06a9\u0633\u062a\u0631\u06cc GG25<\/strong> (\u0645\u0639\u0627\u062f\u0644 ASTM A48 \u06a9\u0644\u0627\u0633 30B) \u0628\u0627 \u0645\u062c\u0627\u0631\u06cc \u0622\u0628 \u062e\u0646\u06a9\u200c\u06a9\u0646\u0646\u062f\u0647 \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647. <strong>\u0622\u0631\u0627\u06cc\u0634 \u062f\u0648 \u0631\u062f\u06cc\u0641\u0647 \u0633\u06cc\u0644\u0646\u062f\u0631\u0647\u0627\u06cc \u0645\u062e\u0627\u0644\u0641<\/strong> provides natural first-order force cancellation, reducing the unbalanced inertia forces transmitted to the foundation by over 80% compared to single-row designs. Despite the massive 15.00-tonne weight, this mechanical advantage permits installation on a <strong>\u0628\u0644\u0648\u06a9 \u0627\u06cc\u0646\u0631\u0633\u06cc \u0628\u062a\u0646 \u0645\u0633\u0644\u062d \u06f2\u06f5 \u062a\u0627 \u06f3\u06f0 \u062a\u0646\u06cc<\/strong>\u2014proportionally lighter than the foundation requirements for single-row compressors of equivalent capacity. This foundation efficiency is particularly valuable for retrofit installations in existing compressor houses where civil modifications are costly and disruptive.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u06f4. \u062f\u0631\u0627\u06cc\u0648 \u0645\u0648\u062a\u0648\u0631 \u0648\u0644\u062a\u0627\u0698 \u0645\u062a\u0648\u0633\u0637 \u200b\u200b\u0628\u0627 \u062a\u0648\u0627\u0646 \u0628\u0627\u0644\u0627<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 is driven by a <strong>\u0645\u0648\u062a\u0648\u0631 \u0627\u0644\u0642\u0627\u06cc\u06cc \u0648\u0644\u062a\u0627\u0698 \u0645\u062a\u0648\u0633\u0637 \u200b\u200b\u06f7\u06f1\u06f0 \u06a9\u06cc\u0644\u0648\u0648\u0627\u062a<\/strong> available in either 6kV or 10kV configurations, conforming to IEC 60034-1 efficiency class IE3. At this power level, medium-voltage drive is essential\u2014a 380V motor would require impractical cable sizes and switchgear ratings. The medium-voltage configuration integrates directly into industrial medium-voltage distribution networks, minimizing I\u00b2R losses in power cabling and improving overall energy efficiency. For large industrial facilities with 6kV or 10kV bus systems, the DW-120\/8 offers seamless electrical compatibility without additional infrastructure investment.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-gas-compressor-General-Assembly-5.webp\" alt=\"DW-120\/8 nitrogen compressor general assembly heavy duty frame\" \/><\/p>\n<\/div>\n<p><!-- Application Scenarios --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0633\u0646\u0627\u0631\u06cc\u0648\u0647\u0627\u06cc \u06a9\u0627\u0631\u0628\u0631\u062f\u06cc<\/h2>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u06a9\u0627\u0631\u062e\u0627\u0646\u0647\u200c\u0647\u0627\u06cc \u062c\u062f\u0627\u0633\u0627\u0632\u06cc \u0647\u0648\u0627\u06cc \u06a9\u0631\u0627\u06cc\u0648\u0698\u0646\u06cc\u06a9 \u062f\u0631 \u0645\u0642\u06cc\u0627\u0633 \u0628\u0632\u0631\u06af<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">In mega-scale cryogenic ASU facilities producing 5,000\u201315,000 Nm\u00b3\/h of gaseous nitrogen, the DW-120\/8 serves as the <strong>\u062a\u0642\u0648\u06cc\u062a \u06a9\u0646\u0646\u062f\u0647 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0627\u0648\u0644\u06cc\u0647 \u0628\u0627 \u0638\u0631\u0641\u06cc\u062a \u0628\u0627\u0644\u0627<\/strong> between the cold box and the extensive distribution network. Its 120 m\u00b3\/min capacity matches the output of the largest standalone ASUs, while the 0.80 MPa discharge pressure provides sufficient head for long-distance pipeline distribution to multiple downstream consumers across an integrated industrial complex. The oil-free design is critical in these applications because any oil contamination would compromise nitrogen purity across the entire distribution network, affecting sensitive processes in semiconductor, pharmaceutical, and food manufacturing facilities served by the same header.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-gas-compressor-application-Cryogenic-air-separation-and-VPSA.webp\" alt=\"DW-120\/8 nitrogen compressor mega scale cryogenic air separation plant\" \/><\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">Large-Scale VPSA Nitrogen Booster Stations<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">For large VPSA nitrogen generator installations producing 99.5\u201399.9% purity nitrogen at near-atmospheric pressure, the <a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600;\" href=\"https:\/\/n2-compressor.com\/fa\/\">DW-120\/8 nitrogen booster<\/a> compresses the low-pressure product to 0.80 MPa for high-pressure distribution across extensive industrial sites. The 120 m\u00b3\/min capacity can serve multiple large VPSA generators operating in parallel, creating a centralized nitrogen supply hub. The oil-free compression path is absolutely essential in VPSA service because hydrocarbon contamination would irreversibly poison the carbon molecular sieve adsorbent, degrading separation efficiency across all generators and necessitating costly adsorbent replacement on a massive scale.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">Integrated Petrochemical Complex Nitrogen Distribution<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">In integrated petrochemical complexes, the DW-120\/8 provides high-pressure nitrogen for <strong>\u0628\u06cc\u200c\u0627\u062b\u0631\u0633\u0627\u0632\u06cc \u0631\u0627\u06a9\u062a\u0648\u0631\u060c \u062d\u0641\u0638 \u06a9\u0627\u062a\u0627\u0644\u06cc\u0632\u0648\u0631\u060c \u067e\u0627\u06a9\u0633\u0627\u0632\u06cc \u062e\u0637 \u0644\u0648\u0644\u0647\u060c \u062a\u0632\u0631\u06cc\u0642 \u0627\u0636\u0637\u0631\u0627\u0631\u06cc \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0648 \u067e\u0648\u0634\u0634\u200c\u062f\u0647\u06cc \u0645\u062e\u0627\u0632\u0646<\/strong> across multiple process units. The 0.80 MPa discharge pressure is sufficient to overcome the pressure ratings of typical process vessels, distillation columns, and reactor systems, allowing direct nitrogen injection without intermediate boosting. The 120 m\u00b3\/min capacity can simultaneously serve an entire complex through a centralized high-pressure nitrogen header, eliminating the need for multiple smaller compressors and reducing overall maintenance complexity. The oil-free certification is mandatory for petrochemical applications where nitrogen contacts catalyst beds or enters process streams.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-gas-compressor-application-Petrochemical-industry.webp\" alt=\"DW-120\/8 nitrogen compressor petrochemical complex distribution\" \/><\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">LNG Regasification Terminal Inerting<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">LNG regasification terminals require massive volumes of nitrogen for <strong>storage tank inerting, pipeline purging, and emergency gas displacement<\/strong> during maintenance and upset conditions. The DW-120\/8\u2019s 120 m\u00b3\/min capacity can rapidly inert large LNG storage tanks and maintain positive nitrogen pressure during product withdrawal cycles. The 0.80 MPa discharge pressure provides adequate head for distribution across the terminal\u2019s extensive piping network. The oil-free design prevents oil contamination of LNG product, which would create off-specification gas and compromise downstream combustion equipment.<\/p>\n<\/div>\n<p><!-- Material & Construction --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0645\u0648\u0627\u062f \u0648 \u0633\u0627\u062e\u062a \u0648 \u0633\u0627\u0632<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 is constructed from premium materials selected for nitrogen compatibility, high-pressure service, and extended operational life at massive scale:<\/p>\n<div style=\"overflow-x: auto;\">\n<table style=\"width: 100%; min-width: 500px; border-collapse: collapse; font-size: clamp(0.85rem,2vw,1rem); margin-bottom: 15px;\">\n<thead>\n<tr style=\"background: #0a2442; color: #ffffff;\">\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u06a9\u0627\u0645\u067e\u0648\u0646\u0646\u062a<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0645\u0648\u0627\u062f<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0645\u0634\u062e\u0635\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0628\u0644\u0648\u06a9 \u0633\u06cc\u0644\u0646\u062f\u0631<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0686\u062f\u0646 \u062e\u0627\u06a9\u0633\u062a\u0631\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">GG25 \/ HT250\u060c \u06a9\u0627\u067e\u0634\u0646\u200c\u0647\u0627\u06cc \u062e\u0646\u06a9\u200c\u06a9\u0646\u0646\u062f\u0647 \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u06cc\u0644 \u0644\u0646\u06af<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0648\u0644\u0627\u062f \u0622\u0644\u06cc\u0627\u0698\u06cc \u0622\u0647\u0646\u06af\u0631\u06cc \u0634\u062f\u0647<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">42CrMo4\u060c Q&amp;T\u060c ISO 1940 G2.5 \u0628\u0627\u0644\u0627\u0646\u0633 \u062f\u06cc\u0646\u0627\u0645\u06cc\u06a9\u06cc<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062d\u0644\u0642\u0647\u200c\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06a9\u0627\u0645\u067e\u0648\u0632\u06cc\u062a PTFE-\u0634\u06cc\u0634\u0647-\u0628\u0631\u0646\u0632<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062e\u0648\u062f \u0631\u0648\u0627\u0646 \u06a9\u0646\u0646\u062f\u0647\u060c \u0645\u0642\u0627\u0648\u0645 \u062f\u0631 \u0628\u0631\u0627\u0628\u0631 \u062f\u0645\u0627\u06cc \u0628\u0627\u0644\u0627 \u062a\u0627 180 \u062f\u0631\u062c\u0647 \u0633\u0627\u0646\u062a\u06cc\u06af\u0631\u0627\u062f<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06af\u0631\u0648\u0647\u200c\u0647\u0627\u06cc \u0633\u0648\u0627\u0631\u06a9\u0627\u0631\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06a9\u0627\u0645\u067e\u0648\u0632\u06cc\u062a PTFE<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0647\u062f\u0627\u06cc\u062a \u067e\u06cc\u0633\u062a\u0648\u0646\u060c \u0636\u062f \u0633\u0627\u06cc\u0634\u060c \u0646\u0631\u062e \u0633\u0627\u06cc\u0634 &lt;0.04 \u0645\u06cc\u0644\u06cc\u200c\u0645\u062a\u0631 \u062f\u0631 1000 \u0633\u0627\u0639\u062a<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0635\u0641\u062d\u0627\u062a \u0633\u0648\u067e\u0627\u067e<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0648\u0644\u0627\u062f \u0636\u062f \u0632\u0646\u06af<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">SS316\u060c \u0637\u0631\u0627\u062d\u06cc \u0641\u0646\u0631\u06cc \u062d\u0644\u0642\u0647\u200c\u0627\u06cc \u0645\u062a\u062d\u062f\u0627\u0644\u0645\u0631\u06a9\u0632<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0645\u06cc\u0644\u0647\u200c\u0647\u0627\u06cc \u0627\u062a\u0635\u0627\u0644<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0648\u0644\u0627\u062f \u0622\u0647\u0646\u06af\u0631\u06cc \u0634\u062f\u0647 \u0628\u0627 \u06cc\u0627\u062a\u0627\u0642\u0627\u0646\u200c\u0647\u0627\u06cc \u0628\u0627\u0628\u06cc\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0627\u0646\u062a\u0647\u0627\u06cc \u0628\u0632\u0631\u06af \u0628\u0627 \u062f\u0642\u062a \u0645\u0627\u0634\u06cc\u0646\u06a9\u0627\u0631\u06cc \u0634\u062f\u0647 \u0648 \u0631\u0648\u063a\u0646 \u06a9\u0627\u0631\u06cc \u0634\u062f\u0647<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0627\u06cc\u0646\u062a\u0631\u06a9\u0648\u0644\u0631<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0644\u0648\u0644\u0647\u200c\u0647\u0627\u06cc \u0641\u0648\u0644\u0627\u062f\u06cc \u06a9\u0631\u0628\u0646\u06cc \/ SS316<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">ASME VIII Div.1\u060c \u0647\u06cc\u062f\u0631\u0648\u062a\u0633\u062a \u06f1.\u06f5\u00d7\u060c \u06f3\u06f0 \u062f\u0642\u06cc\u0642\u0647 \u0646\u06af\u0647\u062f\u0627\u0631\u06cc<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u067e\u0633\u200c\u0633\u0631\u062f\u06a9\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0644\u0648\u0644\u0647\u200c\u0647\u0627\u06cc \u0641\u0648\u0644\u0627\u062f\u06cc \u06a9\u0631\u0628\u0646\u06cc \/ SS316<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">High-capacity finned tube, 32\u00b0C cooling water<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0642\u0627\u0628 \u067e\u0627\u06cc\u0647<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0648\u0644\u0627\u062f \u0633\u0627\u0632\u0647\u200c\u0627\u06cc \u0633\u0646\u06af\u06cc\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0633\u0627\u062e\u062a \u062c\u0648\u0634 \u062f\u0627\u062f\u0647 \u0634\u062f\u0647\u060c \u0646\u0635\u0628 \u0628\u0627 \u0645\u06cc\u0631\u0627\u06cc\u06cc \u0627\u0631\u062a\u0639\u0627\u0634<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">\u062a\u0645\u0627\u0645 \u0627\u062c\u0632\u0627\u06cc \u062a\u062d\u0645\u0644 \u0641\u0634\u0627\u0631 \u0645\u0637\u0627\u0628\u0642 \u0628\u0627 \u0627\u0644\u0632\u0627\u0645\u0627\u062a \u0637\u0631\u0627\u062d\u06cc \u0648 \u0633\u0627\u062e\u062a\u0647 \u0645\u06cc\u200c\u0634\u0648\u0646\u062f. <strong>\u0628\u062e\u0634 1 ASME BPVC \u0628\u062e\u0634 VIII<\/strong> \u06cc\u0627 \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f\u0647\u0627\u06cc GB 150 \u0686\u06cc\u0646. \u0647\u0631 \u0627\u062a\u0635\u0627\u0644 \u062c\u0648\u0634 \u0637\u0628\u0642 \u0645\u0627\u062f\u0647 2 \u0628\u062e\u0634 V \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f ASME\u060c \u062a\u062d\u062a \u0628\u0627\u0632\u0631\u0633\u06cc \u0631\u0627\u062f\u06cc\u0648\u06af\u0631\u0627\u0641\u06cc (RT) 100% \u0642\u0631\u0627\u0631 \u0645\u06cc\u200c\u06af\u06cc\u0631\u062f \u0648 \u0647\u0631 \u0645\u062e\u0632\u0646 \u062a\u062d\u062a \u0641\u0634\u0627\u0631 \u062a\u06a9\u0645\u06cc\u0644\u200c\u0634\u062f\u0647 \u062a\u062d\u062a \u0622\u0632\u0645\u0627\u06cc\u0634 \u0641\u0634\u0627\u0631 \u0647\u06cc\u062f\u0631\u0648\u0627\u0633\u062a\u0627\u062a\u06cc\u06a9 \u0628\u0627 1.5 \u0628\u0631\u0627\u0628\u0631 \u062d\u062f\u0627\u06a9\u062b\u0631 \u0641\u0634\u0627\u0631 \u06a9\u0627\u0631\u06cc \u0645\u062c\u0627\u0632 (MAWP) \u0628\u0647 \u0645\u062f\u062a \u062d\u062f\u0627\u0642\u0644 30 \u062f\u0642\u06cc\u0642\u0647 \u0642\u0631\u0627\u0631 \u0645\u06cc\u200c\u06af\u06cc\u0631\u062f.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-0-gas-compressor-factory-4.jpg\" alt=\"DW-120\/8 nitrogen compressor factory precision machining and quality control\" \/><\/p>\n<\/div>\n<p><!-- Installation & Maintenance --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u062f\u0633\u062a\u0648\u0631\u0627\u0644\u0639\u0645\u0644\u200c\u0647\u0627\u06cc \u0646\u0635\u0628 \u0648 \u0646\u06af\u0647\u062f\u0627\u0631\u06cc<\/h2>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u0627\u0644\u0632\u0627\u0645\u0627\u062a \u0641\u0648\u0646\u062f\u0627\u0633\u06cc\u0648\u0646 \u0648 \u0633\u0627\u0632\u0647<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 has a dry weight of 15.00 tonnes and a center of gravity approximately 1,000 mm above the baseplate. Despite the massive scale, the two-row opposed-cylinder design minimizes unbalanced forces, permitting installation on a <strong>\u0628\u0644\u0648\u06a9 \u0627\u06cc\u0646\u0631\u0633\u06cc \u0628\u062a\u0646 \u0645\u0633\u0644\u062d \u06f2\u06f5 \u062a\u0627 \u06f3\u06f0 \u062a\u0646\u06cc<\/strong>. The block should be mounted on heavy-duty elastomeric vibration isolators (natural frequency 5\u20137 Hz) to prevent vibration transmission to adjacent structures and sensitive instrumentation. Minimum clearance requirements: 2.0 m on the non-drive side for valve access, 1.5 m on the drive side for motor maintenance, and 2.5 m overhead for crane access during major overhauls. The foundation must be designed to support the full static weight plus a dynamic factor of 1.5.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u0637\u0631\u0627\u062d\u06cc \u0633\u06cc\u0633\u062a\u0645 \u0622\u0628 \u062e\u0646\u06a9 \u06a9\u0646\u0646\u062f\u0647<\/h3>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">\u062a\u0642\u0627\u0636\u0627\u06cc \u0622\u0628 \u062e\u0646\u06a9 \u06a9\u0646\u0646\u062f\u0647 \u062a\u0642\u0631\u06cc\u0628\u0627\u064b \u0627\u0633\u062a <strong>\u06f1\u06f2\u06f0 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u062f\u0631 \u0633\u0627\u0639\u062a<\/strong> at an inlet temperature not exceeding 32\u00b0C. The water distribution circuit supplies the cylinder jackets, intercooler, and aftercooler in parallel branches with individual flow control valves. Water quality specifications: pH 6.5\u20138.5, total dissolved solids &lt; 500 mg\/L, chloride content &lt; 50 mg\/L (to prevent SS316 tube corrosion), suspended solids &lt; 30 mg\/L, and total hardness &lt; 300 mg\/L as CaCO\u2083. For sites with marginal water quality, a dedicated closed-loop cooling tower with side-stream filtration, water softening, and chemical treatment is mandatory to prevent scale formation and corrosion in the high-capacity coolers.<\/p>\n<h3 style=\"font-size: clamp(1.1rem,2.5vw,1.3rem); color: #1a3a5c; margin: 25px 0 12px; font-weight: bold;\">\u0628\u0631\u0646\u0627\u0645\u0647 \u0646\u06af\u0647\u062f\u0627\u0631\u06cc \u067e\u06cc\u0634\u06af\u06cc\u0631\u0627\u0646\u0647<\/h3>\n<div style=\"overflow-x: auto;\">\n<table style=\"width: 100%; min-width: 500px; border-collapse: collapse; font-size: clamp(0.85rem,2vw,1rem); margin-bottom: 15px;\">\n<thead>\n<tr style=\"background: #0a2442; color: #ffffff;\">\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0641\u0627\u0635\u0644\u0647<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0645\u0648\u0631\u062f \u062e\u062f\u0645\u0627\u062a<\/th>\n<th style=\"padding: 12px 10px; text-align: left; border: 1px solid #1a3a5c; font-weight: bold;\">\u0627\u0642\u062f\u0627\u0645 \u0644\u0627\u0632\u0645<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0631\u0648\u0632\u0627\u0646\u0647<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0628\u0627\u0632\u0631\u0633\u06cc \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0633\u0637\u062d \u0627\u0631\u062a\u0639\u0627\u0634\u060c \u0633\u0631 \u0648 \u0635\u062f\u0627\u06cc \u063a\u06cc\u0631 \u0637\u0628\u06cc\u0639\u06cc\u060c \u062c\u0631\u06cc\u0627\u0646 \u0622\u0628 \u062e\u0646\u06a9 \u06a9\u0646\u0646\u062f\u0647\u060c \u062f\u0645\u0627\u06cc \u062a\u062e\u0644\u06cc\u0647\u060c \u062f\u0645\u0627\u06cc \u06cc\u0627\u062a\u0627\u0642\u0627\u0646 \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06f2\u06f5\u06f0 \u0633\u0627\u0639\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0628\u0627\u0632\u0631\u0633\u06cc \u0635\u0641\u062d\u0647 \u0634\u06cc\u0631<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0634\u06cc\u0631\u0647\u0627\u06cc \u0645\u06a9\u0634\/\u062f\u0647\u0634 \u0631\u0627 \u0627\u0632 \u0646\u0638\u0631 \u0631\u0633\u0648\u0628\u0627\u062a \u06a9\u0631\u0628\u0646\u06cc\u060c \u0641\u0631\u0633\u0648\u062f\u06af\u06cc \u0641\u0646\u0631 \u06cc\u0627 \u062a\u0631\u06a9 \u062e\u0648\u0631\u062f\u06af\u06cc \u0628\u0631\u0631\u0633\u06cc \u0648 \u062c\u062f\u0627 \u06a9\u0646\u06cc\u062f.<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06f1\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0627\u0631\u0632\u06cc\u0627\u0628\u06cc \u0633\u0627\u06cc\u0634 \u0631\u06cc\u0646\u06af \u067e\u06cc\u0633\u062a\u0648\u0646<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u0641\u0627\u0635\u0644\u0647 \u0634\u06cc\u0627\u0631 \u0631\u06cc\u0646\u06af \u0631\u0627 \u0627\u0646\u062f\u0627\u0632\u0647 \u0628\u06af\u06cc\u0631\u06cc\u062f\u061b \u0627\u06af\u0631 \u0641\u0627\u0635\u0644\u0647 \u0628\u06cc\u0634 \u0627\u0632 0.25 \u0645\u06cc\u0644\u06cc\u200c\u0645\u062a\u0631 \u0628\u0648\u062f\u060c \u0631\u06cc\u0646\u06af\u200c\u0647\u0627 \u0631\u0627 \u062a\u0639\u0648\u06cc\u0636 \u06a9\u0646\u06cc\u062f.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06f4\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062a\u0639\u0645\u06cc\u0631\u0627\u062a \u0627\u0633\u0627\u0633\u06cc \u0645\u06cc\u0627\u0646\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062a\u0645\u0627\u0645 \u0631\u06cc\u0646\u06af\u200c\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646\u060c \u062a\u0633\u0645\u0647\u200c\u0647\u0627\u06cc \u0631\u0627\u062f\u06cc\u0627\u0644 \u0648 \u0645\u062c\u0645\u0648\u0639\u0647\u200c\u0647\u0627\u06cc \u0635\u0641\u062d\u0647 \u0633\u0648\u067e\u0627\u067e \u0631\u0627 \u062a\u0639\u0648\u06cc\u0636 \u06a9\u0646\u06cc\u062f<\/td>\n<\/tr>\n<tr style=\"background: #f8f9fa;\">\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06f8\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u062a\u0639\u0645\u06cc\u0631\u0627\u062a \u0627\u0633\u0627\u0633\u06cc<\/td>\n<td style=\"padding: 10px; border: 1px solid #d6dce4;\">\u06cc\u0627\u062a\u0627\u0642\u0627\u0646\u200c\u0647\u0627\u06cc \u0645\u06cc\u0644\u200c\u0644\u0646\u06af \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f\u060c \u0644\u0642\u06cc \u06cc\u0627\u062a\u0627\u0642\u0627\u0646\u200c\u0647\u0627\u06cc \u0627\u0635\u0644\u06cc \u0631\u0627 \u0627\u0646\u062f\u0627\u0632\u0647\u200c\u06af\u06cc\u0631\u06cc \u06a9\u0646\u06cc\u062f\u060c \u062f\u0631 \u0635\u0648\u0631\u062a \u0628\u0632\u0631\u06af\u062a\u0631 \u0627\u0632 0.08 \u0645\u06cc\u0644\u06cc\u200c\u0645\u062a\u0631 \u0628\u0648\u062f\u0646\u060c \u06cc\u0627\u062a\u0627\u0642\u0627\u0646\u200c\u0647\u0627 \u0631\u0627 \u062a\u0639\u0648\u06cc\u0636 \u06a9\u0646\u06cc\u062f.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The oil-free design of the DW-120\/8 dramatically reduces maintenance complexity compared to lubricated alternatives of equivalent capacity. There are no oil changes to schedule, no lubricating oil samples to analyze, no oil filter elements to replace, and no oil separator cartridges to monitor. The primary consumable wear items are the <strong>\u062d\u0644\u0642\u0647\u200c\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646 \u0648 \u0646\u0648\u0627\u0631\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646\u06cc PTFE<\/strong>, which typically achieve 4,000\u20136,000 hours of service life under clean nitrogen conditions. At this scale, the elimination of oil-related maintenance represents annual savings of $15,000\u2013$25,000 in labor and consumables alone.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-gas-compressor-factory-1.webp\" alt=\"DW-120\/8 nitrogen compressor workshop assembly and quality inspection\" \/><\/p>\n<\/div>\n<p><!-- Compliance & Safety --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u06af\u0648\u0627\u0647\u06cc\u0646\u0627\u0645\u0647\u200c\u0647\u0627\u06cc \u0627\u0646\u0637\u0628\u0627\u0642 \u0648 \u0627\u06cc\u0645\u0646\u06cc<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 nitrogen compressor is designed, manufactured, and tested to meet or exceed the following international standards and regulatory frameworks:<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\">\n<div style=\"flex: 1; min-width: 250px; background: #f8f9fa; padding: 15px; border-left: 4px solid #ff6b35;\"><strong style=\"color: #0a2442; display: block; margin-bottom: 8px;\">\u062f\u0633\u062a\u0648\u0631\u0627\u0644\u0639\u0645\u0644 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0641\u0634\u0627\u0631<\/strong><br \/>\n<span style=\"font-size: 0.95rem;\">ASME BPVC Section VIII Div.1, GB 150-2011, PED 2014\/68\/EU Module A<\/span><\/div>\n<div style=\"flex: 1; min-width: 250px; background: #f8f9fa; padding: 15px; border-left: 4px solid #ff6b35;\"><strong style=\"color: #0a2442; display: block; margin-bottom: 8px;\">\u0627\u06cc\u0645\u0646\u06cc \u0628\u0631\u0642 \u0648 \u0645\u0627\u0634\u06cc\u0646 \u0622\u0644\u0627\u062a<\/strong><br \/>\n<span style=\"font-size: 0.95rem;\">IEC 60034-1 (\u0631\u0627\u0646\u062f\u0645\u0627\u0646 IE3)\u060c IEC 60204-1\u060c ISO 12100 \u0627\u06cc\u0645\u0646\u06cc \u0645\u0627\u0634\u06cc\u0646 \u0622\u0644\u0627\u062a<\/span><\/div>\n<div style=\"flex: 1; min-width: 250px; background: #f8f9fa; padding: 15px; border-left: 4px solid #ff6b35;\"><strong style=\"color: #0a2442; display: block; margin-bottom: 8px;\">\u06a9\u06cc\u0641\u06cc\u062a \u0647\u0648\u0627\u06cc \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646<\/strong><br \/>\n<span style=\"font-size: 0.95rem;\">ISO 8573-1 \u06a9\u0644\u0627\u0633 0 (\u0645\u06cc\u0632\u0627\u0646 \u0631\u0648\u063a\u0646)\u060c \u0622\u0632\u0645\u0627\u06cc\u0634 \u0634\u062f\u0647 \u0628\u0647 \u0637\u0648\u0631 \u0645\u0633\u062a\u0642\u0644 \u062a\u0648\u0633\u0637 T\u00dcV Rheinland<\/span><\/div>\n<div style=\"flex: 1; min-width: 250px; background: #f8f9fa; padding: 15px; border-left: 4px solid #ff6b35;\"><strong style=\"color: #0a2442; display: block; margin-bottom: 8px;\">\u06a9\u06cc\u0641\u06cc\u062a \u0648 \u0645\u062d\u06cc\u0637 \u0632\u06cc\u0633\u062a<\/strong><br \/>\n<span style=\"font-size: 0.95rem;\">ISO 9001:2015 (\u0645\u062f\u06cc\u0631\u06cc\u062a \u06a9\u06cc\u0641\u06cc\u062a)\u060c ISO 14001:2015 (\u0645\u062f\u06cc\u0631\u06cc\u062a \u0645\u062d\u06cc\u0637 \u0632\u06cc\u0633\u062a)<\/span><\/div>\n<\/div>\n<div style=\"background: #fff3cd; border: 1px solid #ffc107; border-radius: 4px; padding: 15px 20px; margin-bottom: 15px;\">\n<p><strong style=\"color: #856404; display: block; margin-bottom: 8px; font-size: 1.1rem;\">\u26a0\ufe0f \u062a\u0648\u0635\u06cc\u0647\u200c\u0647\u0627\u06cc \u0627\u06cc\u0645\u0646\u06cc \u062d\u06cc\u0627\u062a\u06cc<\/strong><\/p>\n<p style=\"color: #856404; margin: 0; font-size: clamp(0.9rem,2vw,1rem);\">Nitrogen is classified as a simple asphyxiant gas. All DW-120\/8 installations must incorporate continuous oxygen deficiency monitoring in the compressor room and all adjacent areas where nitrogen leakage could accumulate. Given the massive 120 m\u00b3\/min capacity, even a minor leak can rapidly displace oxygen in enclosed spaces. Ventilation systems must be engineered to maintain ambient oxygen concentrations above 19.5% volume per OSHA 29 CFR 1910.146. Emergency shutdown interlocks should activate at 19.5% O\u2082 (alarm) and trigger automatic compressor isolation at 18.0% O\u2082 (hard shutdown). Personnel entry procedures into enclosed compressor rooms must include portable oxygen monitors and a buddy-system protocol.<\/p>\n<\/div>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-air-compressor-certificate.webp\" alt=\"DW-120\/8 nitrogen compressor ISO certification and compliance documentation\" \/><\/p>\n<\/div>\n<p><!-- Performance & Efficiency --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u062a\u062d\u0644\u06cc\u0644 \u0639\u0645\u0644\u06a9\u0631\u062f \u0648 \u06a9\u0627\u0631\u0627\u06cc\u06cc<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The DW-120\/8 achieves a <strong>specific power consumption of approximately 5.92 kW per m\u00b3\/min<\/strong> of nitrogen delivered at 0.80 MPa discharge pressure. This efficiency metric is exceptional for an ultra-high-capacity oil-free piston compressor operating at an elevated pressure ratio, positioning the unit in the top tier of the 100+ m\u00b3\/min capacity class. For comparison, oil-lubricated screw compressors in similar high-pressure, high-flow applications typically consume 6.2\u20137.0 kW\/m\u00b3\/min, while legacy piston designs may exceed 7.5 kW\/m\u00b3\/min at equivalent discharge pressures.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">Over a standard 8,000-hour annual operating schedule, the DW-120\/8\u2019s efficiency advantage generates approximately <strong>240,000\u2013480,000 kWh of annual energy savings<\/strong> compared to less efficient alternatives. At an average industrial electricity tariff of $0.08\/kWh, this represents $19,200\u2013$38,400 in direct operating cost reduction per year. When combined with the complete elimination of oil-related consumables (lubricating oil, filter elements, separator cartridges, waste oil disposal, and oil analysis), the <a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600;\" href=\"https:\/\/n2-compressor.com\/fa\/roi-calculation-upgrading-to-efficient-n2-compressors\/\">\u0647\u0632\u06cc\u0646\u0647 \u06a9\u0644 \u0645\u0627\u0644\u06a9\u06cc\u062a \u0628\u0631\u0627\u06cc \u0641\u0634\u0631\u062f\u0647 \u0633\u0627\u0632\u06cc \u0646\u06cc\u062a\u0631\u0648\u0698\u0646<\/a> \u062f\u0631 \u0637\u0648\u0644 \u06cc\u06a9 \u062f\u0648\u0631\u0647 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc 10 \u0633\u0627\u0644\u0647\u060c \u0628\u0647 \u0645\u06cc\u0632\u0627\u0646 \u062a\u062e\u0645\u06cc\u0646\u06cc 22-32% \u06a9\u0627\u0647\u0634 \u0645\u06cc\u200c\u06cc\u0627\u0628\u062f.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">The absence of oil in the compression path also eliminates the energy penalty associated with downstream oil-removal equipment. A typical oil-lubricated compressor of this size would require massive coalescing filter systems, activated carbon adsorber beds, and continuous oil monitoring instrumentation that collectively consume 3\u20135% of the compressor\u2019s power output\u2014equivalent to 21\u201335 kW of parasitic load. The DW-120\/8\u2019s oil-free design removes this parasitic load entirely, further improving effective system efficiency and reducing the electrical infrastructure requirements.<\/p>\n<\/div>\n<p><!-- Customization & OEM --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0642\u0627\u0628\u0644\u06cc\u062a\u200c\u0647\u0627\u06cc \u0633\u0641\u0627\u0631\u0634\u06cc\u200c\u0633\u0627\u0632\u06cc \u0648 \u0646\u0635\u0628\u200c\u0634\u062f\u0647<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">We offer comprehensive customization options to adapt the DW-120\/8 to specific site conditions, integration requirements, and end-user specifications:<\/p>\n<ul style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px; padding-left: 20px;\">\n<li style=\"margin-bottom: 10px;\"><strong>\u0628\u0633\u062a\u0647\u200c\u0647\u0627\u06cc \u0622\u0645\u0627\u062f\u0647 \u062a\u062d\u0648\u06cc\u0644 \u0628\u0627 \u0646\u0635\u0628 \u0631\u0648\u06cc \u0634\u0627\u0633\u06cc:<\/strong> The compressor, motor, intercooler, aftercooler, instrumentation, and control panel are pre-assembled on a heavy structural steel skid with integrated lifting lugs and anchor bolt templates. Factory pre-testing of all systems reduces field installation time by approximately 60% and minimizes commissioning risks.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>\u067e\u06cc\u06a9\u0631\u0628\u0646\u062f\u06cc\u200c\u0647\u0627\u06cc \u0645\u0646\u0637\u0642\u0647 \u062e\u0637\u0631\u0646\u0627\u06a9:<\/strong> \u0645\u062d\u0641\u0638\u0647\u200c\u0647\u0627\u06cc \u0645\u0648\u062a\u0648\u0631 \u0648 \u0628\u0631\u0642 \u0645\u0637\u0627\u0628\u0642 \u0628\u0627 ATEX Zone 2 \u0648 IECEx \u0628\u0631\u0627\u06cc \u0646\u0635\u0628 \u062f\u0631 \u062a\u0623\u0633\u06cc\u0633\u0627\u062a \u067e\u062a\u0631\u0648\u0634\u06cc\u0645\u06cc \u06a9\u0647 \u0645\u0645\u06a9\u0646 \u0627\u0633\u062a \u06af\u0627\u0647\u06cc \u0627\u0648\u0642\u0627\u062a \u062f\u0631 \u0622\u0646\u0647\u0627 \u062c\u0648\u0647\u0627\u06cc \u0627\u0646\u0641\u062c\u0627\u0631\u06cc \u0648\u062c\u0648\u062f \u062f\u0627\u0634\u062a\u0647 \u0628\u0627\u0634\u062f\u060c \u062f\u0631 \u062f\u0633\u062a\u0631\u0633 \u0647\u0633\u062a\u0646\u062f. \u0645\u06cc\u200c\u062a\u0648\u0627\u0646 \u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u062a\u0634\u062e\u06cc\u0635 \u06af\u0627\u0632 \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647 \u0648 \u0642\u0641\u0644\u200c\u0647\u0627\u06cc \u062a\u0647\u0648\u06cc\u0647 \u062e\u0648\u062f\u06a9\u0627\u0631 \u0631\u0627 \u062f\u0631 \u0633\u06cc\u0633\u062a\u0645 \u06a9\u0646\u062a\u0631\u0644 \u06af\u0646\u062c\u0627\u0646\u062f.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>\u06a9\u0646\u062a\u0631\u0644 \u0641\u0631\u0622\u06cc\u0646\u062f \u067e\u06cc\u0634\u0631\u0641\u062a\u0647:<\/strong> Optional Siemens S7-1500 or Allen-Bradley ControlLogix PLC with 15-inch HMI touchscreen, remote monitoring via Modbus TCP\/IP or OPC-UA, and seamless integration with plant DCS\/SCADA systems. Automatic load\/unload control, variable frequency drive (VFD) compatibility, and predictive maintenance algorithms optimize part-load efficiency and reduce mechanical wear.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>\u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u062d\u0641\u0627\u0638\u062a \u0627\u0632 \u0645\u062d\u06cc\u0637 \u0632\u06cc\u0633\u062a:<\/strong> C5-M marine-grade coating systems for coastal or offshore installations; tropicalized electrical components for ambient temperatures up to 55\u00b0C; and IP54-rated acoustic enclosures that reduce noise emission from 88 dB(A) to 74 dB(A) at 1 meter, suitable for installations near administrative buildings or residential areas.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>\u0628\u0631\u0646\u0627\u0645\u0647\u200c\u0647\u0627\u06cc OEM \u0648 \u0628\u0631\u0686\u0633\u0628 \u062e\u0635\u0648\u0635\u06cc:<\/strong> \u0631\u0646\u06af\u200c\u0647\u0627\u06cc \u0633\u0641\u0627\u0631\u0634\u06cc\u060c \u067e\u0644\u0627\u06a9\u200c\u0647\u0627\u06cc \u0628\u0631\u0646\u062f \u0648 \u0628\u0633\u062a\u0647\u200c\u0647\u0627\u06cc \u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0645\u062d\u0644\u06cc \u0628\u0631\u0627\u06cc \u062a\u0648\u0632\u06cc\u0639\u200c\u06a9\u0646\u0646\u062f\u06af\u0627\u0646 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u06af\u0627\u0632 \u0648 \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647\u200c\u0633\u0627\u0632\u0627\u0646 \u0633\u06cc\u0633\u062a\u0645 \u062f\u0631 \u062f\u0633\u062a\u0631\u0633 \u0647\u0633\u062a\u0646\u062f. \u062f\u0641\u062a\u0631\u0686\u0647\u200c\u0647\u0627\u06cc \u0631\u0627\u0647\u0646\u0645\u0627\u06cc \u0641\u0646\u06cc\u060c \u0644\u06cc\u0633\u062a \u0642\u0637\u0639\u0627\u062a \u06cc\u062f\u06a9\u06cc \u0648 \u0631\u0648\u06cc\u0647\u200c\u0647\u0627\u06cc \u0646\u06af\u0647\u062f\u0627\u0631\u06cc \u0645\u06cc\u200c\u062a\u0648\u0627\u0646\u0646\u062f \u0628\u0647 \u0686\u0646\u062f\u06cc\u0646 \u0632\u0628\u0627\u0646 \u0627\u0631\u0627\u0626\u0647 \u0634\u0648\u0646\u062f.<\/li>\n<\/ul>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\">\u067e\u06cc\u06a9\u0631\u0628\u0646\u062f\u06cc\u200c\u0647\u0627\u06cc \u0633\u0641\u0627\u0631\u0634\u06cc \u0627\u0632 [\u0646\u0627\u0645 \u0634\u0631\u06a9\u062a\/\u0634\u0631\u06a9\u062a\/...] \u062f\u0631 \u062f\u0633\u062a\u0631\u0633 \u0647\u0633\u062a\u0646\u062f. <strong>\u062d\u062f\u0627\u0642\u0644 \u0633\u0641\u0627\u0631\u0634 \u06f1 \u0648\u0627\u062d\u062f<\/strong>. Engineering review and proposal generation typically require 7\u201310 business days due to the complexity of ultra-high-capacity systems. Standard delivery time is 14\u201316 weeks; repeat orders are delivered in 10\u201312 weeks from order confirmation.<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/0-gas-compressor-case-photo-2.webp\" alt=\"DW-120\/8 nitrogen compressor custom skid mounted package installation\" \/><\/p>\n<\/div>\n<p><!-- Case Study --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">Case Study: Integrated Petrochemical Complex Nitrogen Hub<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\"><strong>\u0645\u0634\u062a\u0631\u06cc:<\/strong> A major integrated petrochemical complex in the Middle East with ethylene crackers, polyethylene plants, and aromatics units<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\"><strong>\u0686\u0627\u0644\u0634:<\/strong> The complex was operating three aging oil-lubricated nitrogen compressors (combined capacity 100 m\u00b3\/min at 0.60 MPa) that were experiencing frequent oil carryover into the nitrogen distribution network. Oil contamination was fouling catalyst beds in the ethylene crackers, causing unplanned shutdowns costing $500,000 per event. The 0.60 MPa pressure was also insufficient for new high-pressure reactor inerting requirements. Maintenance costs across the three compressors had escalated to $220,000\/year, and spare parts availability was becoming problematic due to the age of the equipment.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\"><strong>\u0631\u0627\u0647 \u062d\u0644:<\/strong> \u0645\u0627 \u06cc\u06a9 \u062a\u06a9\u200c\u0646\u0633\u062e\u0647 \u0639\u0631\u0636\u0647 \u06a9\u0631\u062f\u06cc\u0645 <strong>DW-120\/8 oil-free nitrogen compressor<\/strong> to replace all three aging units, configured on a custom skid with integrated intercooler, aftercooler, and a Siemens S7-1500 PLC control panel with full SCADA integration. The 0.80 MPa discharge pressure met all new high-pressure inerting requirements, while the 120 m\u00b3\/min capacity provided a 20% margin above peak demand. A 10 m\u00b3 surge vessel was installed upstream to buffer demand fluctuations across the complex. The oil-free design eliminated catalyst bed fouling entirely.<\/p>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\"><strong>\u0646\u062a\u0627\u06cc\u062c \u06a9\u0645\u06cc \u067e\u0633 \u0627\u0632 30 \u0645\u0627\u0647:<\/strong><\/p>\n<ul style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px; padding-left: 20px;\">\n<li style=\"margin-bottom: 8px;\">\u0645\u06cc\u0632\u0627\u0646 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0631\u0648\u063a\u0646: <strong>\u0627\u0632 \u06f5.\u06f8 \u0645\u06cc\u0644\u06cc\u200c\u06af\u0631\u0645 \u0628\u0631 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u0628\u0647 \u06a9\u0645\u062a\u0631 \u0627\u0632 \u06f0.\u06f0\u06f1 \u0645\u06cc\u0644\u06cc\u200c\u06af\u0631\u0645 \u0628\u0631 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u06a9\u0627\u0647\u0634 \u06cc\u0627\u0641\u062a<\/strong>\u060c \u0627\u062e\u0630 \u06af\u0648\u0627\u0647\u06cc\u0646\u0627\u0645\u0647 ISO 8573-1 \u06a9\u0644\u0627\u0633 0<\/li>\n<li style=\"margin-bottom: 8px;\">Catalyst bed fouling incidents: <strong>\u06a9\u0627\u0645\u0644\u0627\u064b \u062d\u0630\u0641 \u0634\u062f<\/strong>, saving $500,000 per avoided shutdown<\/li>\n<li style=\"margin-bottom: 8px;\">\u0647\u0632\u06cc\u0646\u0647 \u0646\u06af\u0647\u062f\u0627\u0631\u06cc \u0633\u0627\u0644\u0627\u0646\u0647: <strong>\u06a9\u0627\u0647\u0634 \u06cc\u0627\u0641\u062a\u0647 \u062a\u0648\u0633\u0637 48%<\/strong> ($220,000 to $114,400) through elimination of oil-related repairs across three units<\/li>\n<li style=\"margin-bottom: 8px;\">\u0645\u0635\u0631\u0641 \u0627\u0646\u0631\u0698\u06cc: <strong>\u0628\u0647\u0628\u0648\u062f \u06cc\u0627\u0641\u062a\u0647 \u062a\u0648\u0633\u0637 8.2%<\/strong> versus the three replaced units, saving approximately $42,000\/year<\/li>\n<li style=\"margin-bottom: 8px;\">\u06a9\u0627\u0647\u0634 \u0631\u062f\u067e\u0627: <strong>Replaced three compressors with one<\/strong>, freeing 40 m\u00b2 of compressor house space<\/li>\n<li style=\"margin-bottom: 8px;\">\u062e\u0631\u0627\u0628\u06cc\u200c\u0647\u0627\u06cc \u0628\u0631\u0646\u0627\u0645\u0647\u200c\u0631\u06cc\u0632\u06cc \u0646\u0634\u062f\u0647: <strong>\u0635\u0641\u0631 \u0631\u0648\u06cc\u062f\u0627\u062f<\/strong> \u062f\u0631 30 \u0645\u0627\u0647 \u06a9\u0627\u0631\u06a9\u0631\u062f \u0645\u062f\u0627\u0648\u0645<\/li>\n<\/ul>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 0 0 15px;\"><em>\u201cThe DW-120\/8 has been a game-changer for our nitrogen supply. Eliminating oil contamination saved us from two catalyst bed replacements that would have cost $2.5 million each. The single-unit simplicity has reduced our maintenance team workload by 60%, and the energy savings are a welcome bonus.\u201d<\/em> - \u0645\u062f\u06cc\u0631 \u0627\u0631\u0634\u062f \u0639\u0645\u0644\u06cc\u0627\u062a\u060c \u0645\u062c\u062a\u0645\u0639 \u067e\u062a\u0631\u0648\u0634\u06cc\u0645\u06cc<\/p>\n<p><img decoding=\"async\" style=\"max-width: 100%; height: auto; display: block; margin: 15px auto; border-radius: 4px;\" src=\"https:\/\/n2-compressor.com\/wp-content\/uploads\/2026\/07\/gas-compressor-case-photo-3.jpg\" alt=\"DW-120\/8 nitrogen compressor petrochemical complex installation case study\" \/><\/p>\n<\/div>\n<p><!-- FAQ --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0633\u0648\u0627\u0644\u0627\u062a \u0645\u062a\u062f\u0627\u0648\u0644 \u0648 \u0631\u0627\u0647\u0646\u0645\u0627\u06cc \u0627\u0646\u062a\u062e\u0627\u0628<\/h2>\n<details style=\"margin-bottom: 12px; border: 1px solid #d6dce4; border-radius: 4px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; background: #f8f9fa; cursor: pointer; font-weight: bold; color: #0a2442; font-size: clamp(1rem,2.5vw,1.1rem); list-style: none; position: relative;\">What is the expected service life of the DW-120\/8 under normal operating conditions?<\/summary>\n<div style=\"padding: 15px 18px; background: #ffffff;\">\n<p style=\"margin: 0; font-size: clamp(1rem,2.5vw,1.15rem);\">The DW-120\/8 is engineered for a <strong>\u062d\u062f\u0627\u0642\u0644 \u0639\u0645\u0631 \u0637\u0631\u0627\u062d\u06cc \u06f1\u06f5 \u0633\u0627\u0644<\/strong> (\u062a\u0642\u0631\u06cc\u0628\u0627\u064b \u06f1\u06f2\u06f0\u060c\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a \u06a9\u0627\u0631\u06a9\u0631\u062f) \u062f\u0631 \u0633\u0631\u0648\u06cc\u0633 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u062a\u0645\u06cc\u0632. \u0634\u0627\u0633\u06cc \u0686\u062f\u0646\u06cc \u0639\u0638\u06cc\u0645 \u0648 \u0645\u06cc\u0644 \u0644\u0646\u06af \u0641\u0648\u0644\u0627\u062f\u06cc \u0641\u0648\u0631\u062c \u0634\u062f\u0647 \u0628\u0631\u0627\u06cc \u0637\u0648\u0644 \u0639\u0645\u0631 \u06a9\u0627\u0645\u0644 \u0637\u0631\u0627\u062d\u06cc \u0648 \u062a\u0646\u0647\u0627 \u0628\u0627 \u0628\u0627\u0632\u0631\u0633\u06cc\u200c\u0647\u0627\u06cc \u062f\u0648\u0631\u0647\u200c\u0627\u06cc \u06cc\u0627\u062a\u0627\u0642\u0627\u0646\u200c\u0647\u0627\u060c \u0631\u062a\u0628\u0647\u200c\u0628\u0646\u062f\u06cc \u0634\u062f\u0647\u200c\u0627\u0646\u062f. \u0631\u06cc\u0646\u06af\u200c\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646 \u0648 \u0646\u0648\u0627\u0631\u0647\u0627\u06cc \u0633\u0648\u0627\u0631 \u0634\u0648\u0646\u062f\u0647 PTFE \u0627\u062c\u0632\u0627\u06cc \u0627\u0635\u0644\u06cc \u0633\u0627\u06cc\u0634 \u0647\u0633\u062a\u0646\u062f \u06a9\u0647 \u0628\u0633\u062a\u0647 \u0628\u0647 \u062f\u0645\u0627\u06cc \u062a\u062e\u0644\u06cc\u0647\u060c \u06a9\u06cc\u0641\u06cc\u062a \u0641\u06cc\u0644\u062a\u0631\u0627\u0633\u06cc\u0648\u0646 \u0648\u0631\u0648\u062f\u06cc \u0648 \u0636\u0631\u06cc\u0628 \u0628\u0627\u0631\u060c \u0645\u0639\u0645\u0648\u0644\u0627\u064b \u0628\u06cc\u0646 \u06f4\u06f0\u06f0\u06f0 \u062a\u0627 \u06f6\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a \u0637\u0648\u0644 \u0639\u0645\u0631 \u062a\u0639\u0648\u06cc\u0636 \u062f\u0627\u0631\u0646\u062f. \u0645\u062c\u0645\u0648\u0639\u0647 \u0635\u0641\u062d\u0627\u062a \u0633\u0648\u067e\u0627\u067e \u0645\u0639\u0645\u0648\u0644\u0627\u064b \u0642\u0628\u0644 \u0627\u0632 \u0646\u06cc\u0627\u0632 \u0628\u0647 \u0628\u0627\u0632\u0633\u0627\u0632\u06cc\u060c \u06f2\u06f5\u06f0\u06f0 \u062a\u0627 \u06f4\u06f0\u06f0\u06f0 \u0633\u0627\u0639\u062a \u0639\u0645\u0631 \u0645\u06cc\u200c\u06a9\u0646\u0646\u062f.<\/p>\n<\/div>\n<\/details>\n<details style=\"margin-bottom: 12px; border: 1px solid #d6dce4; border-radius: 4px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; background: #f8f9fa; cursor: pointer; font-weight: bold; color: #0a2442; font-size: clamp(1rem,2.5vw,1.1rem); list-style: none; position: relative;\">Can the DW-120\/8 handle the pulsating inlet pressure from multiple VPSA nitrogen generators?<\/summary>\n<div style=\"padding: 15px 18px; background: #ffffff;\">\n<p style=\"margin: 0; font-size: clamp(1rem,2.5vw,1.15rem);\">Yes. The DW-120\/8 can accommodate <strong>\u062a\u063a\u06cc\u06cc\u0631\u0627\u062a \u0641\u0634\u0627\u0631 \u0648\u0631\u0648\u062f\u06cc \u0627\u0632 0.03 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644 \u062a\u0627 0.12 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644<\/strong> without performance degradation or mechanical distress. For large VPSA installations where multiple generators operate with staggered adsorption cycles, we strongly recommend installing a <strong>\u0645\u062e\u0632\u0646 \u0633\u0631\u062c \u0628\u0627 \u062d\u062f\u0627\u0642\u0644 \u062d\u062c\u0645 \u06f1\u06f0 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628<\/strong> upstream of the compressor suction to dampen pressure pulsations, protect the compressor valves from hydraulic shock, and provide a buffer during VPSA cycle transitions. For installations with severe pulsation, an optional pulsation dampener can be fitted to the suction manifold.<\/p>\n<\/div>\n<\/details>\n<details style=\"margin-bottom: 12px; border: 1px solid #d6dce4; border-radius: 4px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; background: #f8f9fa; cursor: pointer; font-weight: bold; color: #0a2442; font-size: clamp(1rem,2.5vw,1.1rem); list-style: none; position: relative;\">Is the DW-120\/8 suitable for outdoor installation without a dedicated compressor house?<\/summary>\n<div style=\"padding: 15px 18px; background: #ffffff;\">\n<p style=\"margin: 0; font-size: clamp(1rem,2.5vw,1.15rem);\">The standard DW-120\/8 is designed for <strong>\u0646\u0635\u0628 \u062f\u0627\u062e\u0644\u06cc<\/strong> \u062f\u0631 \u06cc\u06a9 \u0627\u062a\u0627\u0642 \u0645\u0627\u0634\u06cc\u0646 \u0622\u0644\u0627\u062a \u062a\u0647\u0648\u06cc\u0647 \u0634\u062f\u0647. \u0628\u0631\u0627\u06cc \u0646\u0635\u0628 \u062f\u0631 \u0641\u0636\u0627\u06cc \u0628\u0627\u0632\u060c \u0645\u0627 \u06cc\u06a9 \u06af\u0632\u06cc\u0646\u0647 \u0627\u062e\u062a\u06cc\u0627\u0631\u06cc \u0627\u0631\u0627\u0626\u0647 \u0645\u06cc \u062f\u0647\u06cc\u0645 <strong>\u0645\u062d\u0641\u0638\u0647 \u0645\u0642\u0627\u0648\u0645 \u062f\u0631 \u0628\u0631\u0627\u0628\u0631 \u0622\u0628 \u0648 \u0647\u0648\u0627 \u0628\u0627 \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f IP54<\/strong> with integrated space heating (for cold climates down to -20\u00b0C), solar radiation shields (for tropical climates up to 55\u00b0C ambient), and forced ventilation with filtration. The acoustic enclosure option is strongly recommended for outdoor installations to maintain noise compliance with local regulations (typically 75 dB(A) at property boundary). Given the massive scale, a dedicated compressor house is generally preferred for ease of maintenance and environmental control.<\/p>\n<\/div>\n<\/details>\n<details style=\"margin-bottom: 12px; border: 1px solid #d6dce4; border-radius: 4px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; background: #f8f9fa; cursor: pointer; font-weight: bold; color: #0a2442; font-size: clamp(1rem,2.5vw,1.1rem); list-style: none; position: relative;\">How does the DW-120\/8 compare to multiple smaller compressors for large-scale nitrogen supply?<\/summary>\n<div style=\"padding: 15px 18px; background: #ffffff;\">\n<p style=\"margin: 0; font-size: clamp(1rem,2.5vw,1.15rem);\">While multiple smaller compressors offer redundancy and flexibility, a single <strong>DW-120\/8 provides significant advantages<\/strong> in large-scale applications: (1) Lower total capital cost\u2014one large compressor is typically 15\u201325% less expensive than multiple smaller units of equivalent combined capacity; (2) Reduced maintenance complexity\u2014one set of wear parts versus multiple sets; (3) Higher overall efficiency\u2014large compressors achieve better thermodynamic efficiency at design load; (4) Smaller footprint\u2014one unit occupies less space than multiple compressors with their associated piping and electrical infrastructure; (5) Simpler control\u2014single-unit load management versus complex lead\/lag sequencing. For critical applications requiring 100% redundancy, two DW-120\/8 units in a lead\/standby arrangement provide superior reliability than three or four smaller compressors. For a comprehensive TCO comparison, refer to our <a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600;\" href=\"https:\/\/n2-compressor.com\/fa\/roi-calculation-upgrading-to-efficient-n2-compressors\/\">\u062a\u062c\u0632\u06cc\u0647 \u0648 \u062a\u062d\u0644\u06cc\u0644 \u0628\u0627\u0632\u06af\u0634\u062a \u0633\u0631\u0645\u0627\u06cc\u0647 \u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646<\/a>.<\/p>\n<\/div>\n<\/details>\n<details style=\"margin-bottom: 12px; border: 1px solid #d6dce4; border-radius: 4px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; background: #f8f9fa; cursor: pointer; font-weight: bold; color: #0a2442; font-size: clamp(1rem,2.5vw,1.1rem); list-style: none; position: relative;\">Under what circumstances should I avoid selecting the DW-120\/8?<\/summary>\n<div style=\"padding: 15px 18px; background: #ffffff;\">\n<p style=\"margin: 0; font-size: clamp(1rem,2.5vw,1.15rem);\">The DW-120\/8 is NOT the optimal choice for: (1) <strong>\u0641\u0634\u0627\u0631\u0647\u0627\u06cc \u062a\u062e\u0644\u06cc\u0647 \u0628\u06cc\u0634 \u0627\u0632 \u06f1.\u06f0\u06f0 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644<\/strong>\u2014 \u0628\u0631\u0627\u06cc \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u0641\u0634\u0627\u0631 \u0628\u0627\u0644\u0627\u062a\u0631\u060c \u0633\u0631\u06cc \u0686\u0646\u062f \u0645\u0631\u062d\u0644\u0647\u200c\u0627\u06cc ZW \u0645\u0627 (\u062a\u0627 9.00 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644) \u0631\u0627 \u062f\u0631 \u0646\u0638\u0631 \u0628\u06af\u06cc\u0631\u06cc\u062f\u061b (2) <strong>Capacity requirements below 60 m\u00b3\/min<\/strong>\u2014 \u0648\u0627\u062d\u062f\u0647\u0627\u06cc \u06a9\u0648\u0686\u06a9\u062a\u0631 \u062f\u0631 \u0633\u0631\u06cc LW \u06cc\u0627 MW \u0631\u0627\u0646\u062f\u0645\u0627\u0646 \u0628\u0627\u0631 \u062c\u0632\u0626\u06cc \u0628\u0631\u062a\u0631 \u0648 \u0647\u0632\u06cc\u0646\u0647 \u0633\u0631\u0645\u0627\u06cc\u0647 \u06af\u0630\u0627\u0631\u06cc \u0628\u0647 \u0637\u0648\u0631 \u0642\u0627\u0628\u0644 \u062a\u0648\u062c\u0647\u06cc \u067e\u0627\u06cc\u06cc\u0646 \u062a\u0631\u06cc \u0627\u0631\u0627\u0626\u0647 \u0645\u06cc \u062f\u0647\u0646\u062f\u061b (3) <strong>\u06a9\u0627\u0631\u0628\u0631\u062f\u0647\u0627\u06cc\u06cc \u06a9\u0647 \u0646\u06cc\u0627\u0632 \u0628\u0647 \u0645\u062f\u0648\u0644\u0627\u0633\u06cc\u0648\u0646 \u062c\u0631\u06cc\u0627\u0646 \u067e\u06cc\u0648\u0633\u062a\u0647 \u0632\u06cc\u0631 \u0638\u0631\u0641\u06cc\u062a \u0646\u0627\u0645\u06cc 40% \u062f\u0627\u0631\u0646\u062f<\/strong>\u2014piston compressors experience reduced efficiency at deep turndown; a dual-compressor arrangement with a smaller standby unit may be more economical for highly variable demand profiles; (4) <strong>Sites without medium-voltage electrical infrastructure<\/strong>\u2014the 710 kW motor requires 6kV or 10kV supply; facilities with only 380V distribution would require costly electrical upgrades.<\/p>\n<\/div>\n<\/details>\n<\/div>\n<p><!-- Related Products --><\/p>\n<div style=\"margin-bottom: 40px;\">\n<h2 style=\"font-size: clamp(1.4rem,3vw,1.8rem); color: #0a2442; margin: 0 0 18px; font-weight: bold; border-bottom: 3px solid #ff6b35; padding-bottom: 8px; display: inline-block;\">\u0645\u062d\u0635\u0648\u0644\u0627\u062a \u0648 \u0631\u0627\u0647\u06a9\u0627\u0631\u0647\u0627\u06cc \u0645\u0631\u062a\u0628\u0637<\/h2>\n<div style=\"display: flex; flex-wrap: wrap; gap: 15px;\">\n<div style=\"flex: 1; min-width: 280px; background: #f8f9fa; padding: 20px; border-radius: 4px;\">\n<h3 style=\"color: #0a2442; margin: 0 0 10px; font-size: 1.15rem;\"><a style=\"color: #0a2442; text-decoration: none;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0628\u0627 \u0638\u0631\u0641\u06cc\u062a \u0628\u0627\u0644\u0627 \u0633\u0631\u06cc LW<\/a><\/h3>\n<p style=\"margin: 0 0 12px; font-size: 0.95rem; color: #444;\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646\u06cc \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646 \u0628\u0627 \u062c\u0631\u06cc\u0627\u0646 \u0628\u0627\u0644\u0627 (20 \u062a\u0627 60 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u062f\u0631 \u062f\u0642\u06cc\u0642\u0647) \u0628\u0631\u0627\u06cc \u067e\u0634\u062a\u06cc\u0628\u0627\u0646 \u06af\u06cc\u0631\u06cc \u0627\u0632 \u0648\u0627\u062d\u062f \u0647\u0648\u0627\u06cc \u0641\u0634\u0631\u062f\u0647 \u0628\u0631\u0648\u062f\u062a\u06cc\u060c \u062a\u0642\u0648\u06cc\u062a VPSA \u0648 \u062a\u0648\u0632\u06cc\u0639 \u062e\u0637 \u0644\u0648\u0644\u0647 \u0635\u0646\u0639\u062a\u06cc \u0628\u0627 \u0641\u0634\u0627\u0631 \u0645\u062a\u0648\u0633\u0637. \u0641\u0634\u0627\u0631\u0647\u0627\u06cc \u062a\u062e\u0644\u06cc\u0647 \u0627\u0632 0.30 \u062a\u0627 0.80 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644.<\/p>\n<p><a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600; font-size: 0.95rem;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u0633\u0631\u06cc LW \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f \u2192<\/a><\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 280px; background: #f8f9fa; padding: 20px; border-radius: 4px;\">\n<h3 style=\"color: #0a2442; margin: 0 0 10px; font-size: 1.15rem;\"><a style=\"color: #0a2442; text-decoration: none;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646 \u0686\u0646\u062f \u0645\u0631\u062d\u0644\u0647\u200c\u0627\u06cc \u0633\u0631\u06cc ZW<\/a><\/h3>\n<p style=\"margin: 0 0 12px; font-size: 0.95rem; color: #444;\">Vertical, multi-stage oil-free compressors for oxygen, nitrogen, hydrogen, and specialty gases. Discharge pressures up to 9.00 MPa for ultra-high-pressure gas filling, cylinder charging, and chemical synthesis.<\/p>\n<p><a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600; font-size: 0.95rem;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u0633\u0631\u06cc ZW \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f \u2192<\/a><\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 280px; background: #f8f9fa; padding: 20px; border-radius: 4px;\">\n<h3 style=\"color: #0a2442; margin: 0 0 10px; font-size: 1.15rem;\"><a style=\"color: #0a2442; text-decoration: none;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u0641\u0634\u0627\u0631 \u0645\u062a\u0648\u0633\u0637 \u200b\u200b\u0633\u0631\u06cc MW<\/a><\/h3>\n<p style=\"margin: 0 0 12px; font-size: 0.95rem; color: #444;\">Medium-pressure oil-free compressors (1.0\u20134.0 MPa) for nitrogen recycle, gas liquefaction booster duty, and high-pressure process gas compression in petrochemical and refinery operations.<\/p>\n<p><a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600; font-size: 0.95rem;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u0633\u0631\u06cc MW \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f \u2192<\/a><\/p>\n<\/div>\n<\/div>\n<p style=\"font-size: clamp(1rem,2.5vw,1.15rem); margin: 20px 0 0;\">\u0628\u0631\u0627\u06cc \u06cc\u06a9 \u0645\u0631\u0648\u0631 \u06a9\u0644\u06cc \u062c\u0627\u0645\u0639 \u0627\u0632 \u0645\u0627 <a style=\"color: #ff6b35; text-decoration: underline; font-weight: 600;\" href=\"https:\/\/n2-compressor.com\/fa\/\">\u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u0635\u0646\u0639\u062a\u06cc<\/a> \u0628\u0631\u0627\u06cc \u0627\u0637\u0644\u0627\u0639 \u0627\u0632 \u0646\u0645\u0648\u0646\u0647 \u06a9\u0627\u0631\u0647\u0627\u06cc \u0645\u0627\u060c \u0634\u0627\u0645\u0644 \u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u0627\u06a9\u0633\u06cc\u0698\u0646 \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646\u060c \u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u0647\u06cc\u062f\u0631\u0648\u0698\u0646\u060c \u06a9\u0645\u067e\u0631\u0633\u0648\u0631\u0647\u0627\u06cc \u062f\u06cc \u0627\u06a9\u0633\u06cc\u062f \u06a9\u0631\u0628\u0646 \u0648 \u0631\u0627\u0647\u06a9\u0627\u0631\u0647\u0627\u06cc \u062a\u062e\u0635\u0635\u06cc \u06af\u0627\u0632\u0633\u0648\u0632 \u0633\u0641\u0627\u0631\u0634\u06cc\u060c \u0644\u0637\u0641\u0627\u064b \u0628\u0627 \u062a\u06cc\u0645 \u0645\u0647\u0646\u062f\u0633\u06cc \u06a9\u0627\u0631\u0628\u0631\u062f\u06cc \u0645\u0627 \u062a\u0645\u0627\u0633 \u0628\u06af\u06cc\u0631\u06cc\u062f \u06cc\u0627 \u06a9\u0627\u062a\u0627\u0644\u0648\u06af \u0645\u062d\u0635\u0648\u0644\u0627\u062a \u0622\u0646\u0644\u0627\u06cc\u0646 \u0645\u0627 \u0631\u0627 \u0645\u0631\u0648\u0631 \u06a9\u0646\u06cc\u062f.<\/p>\n<\/div>\n<p><!-- CTA Section --><\/p>\n<div style=\"background: linear-gradient(135deg,#0a2442 0%,#1a3a5c 100%); padding: 50px 20px; text-align: center; border-radius: 0; margin-bottom: 30px;\">\n<h2 style=\"font-size: clamp(1.5rem,3.5vw,2.2rem); color: #ffffff; margin: 0 0 15px; font-weight: bold;\">\u0622\u0645\u0627\u062f\u0647\u200c\u0627\u06cc\u062f \u062a\u0627 \u0632\u06cc\u0631\u0633\u0627\u062e\u062a \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 \u062f\u0631 \u0645\u0642\u06cc\u0627\u0633 \u0628\u0632\u0631\u06af \u062e\u0648\u062f \u0631\u0627 \u0645\u062a\u062d\u0648\u0644 \u06a9\u0646\u06cc\u062f\u061f<\/h2>\n<p style=\"font-size: clamp(1rem,2.5vw,1.2rem); color: #d6dce4; margin: 0 0 25px; max-width: 800px; margin-left: auto; margin-right: auto;\">\u0645\u0647\u0646\u062f\u0633\u0627\u0646 \u0645\u0627 \u0622\u0645\u0627\u062f\u0647\u200c\u0627\u0646\u062f \u062a\u0627 \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u062c\u0631\u06cc\u0627\u0646 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646\u060c \u0634\u0631\u0627\u06cc\u0637 \u0645\u06a9\u0634\u060c \u0627\u0647\u062f\u0627\u0641 \u0641\u0634\u0627\u0631 \u062a\u062e\u0644\u06cc\u0647 \u0648 \u0645\u062d\u062f\u0648\u062f\u06cc\u062a\u200c\u0647\u0627\u06cc \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647\u200c\u0633\u0627\u0632\u06cc \u0634\u0645\u0627 \u0631\u0627 \u0627\u0631\u0632\u06cc\u0627\u0628\u06cc \u06a9\u0646\u0646\u062f. \u0645\u0627 \u0638\u0631\u0641 \u06f4\u06f8 \u0633\u0627\u0639\u062a \u067e\u0633 \u0627\u0632 \u062f\u0631\u06cc\u0627\u0641\u062a \u062f\u0631\u062e\u0648\u0627\u0633\u062a \u0634\u0645\u0627\u060c \u067e\u06cc\u0634\u0646\u0647\u0627\u062f\u0647\u0627\u06cc \u0641\u0646\u06cc \u0631\u0627\u06cc\u06af\u0627\u0646\u060c \u0646\u0642\u0634\u0647\u200c\u0647\u0627\u06cc \u0686\u06cc\u062f\u0645\u0627\u0646 \u0641\u0648\u0646\u062f\u0627\u0633\u06cc\u0648\u0646\u060c \u0646\u0645\u0648\u062f\u0627\u0631\u0647\u0627\u06cc \u0644\u0648\u0644\u0647\u200c\u06a9\u0634\u06cc \u0648 \u0627\u0628\u0632\u0627\u0631 \u062f\u0642\u06cc\u0642 (P&amp;ID) \u0648 \u062a\u062c\u0632\u06cc\u0647 \u0648 \u062a\u062d\u0644\u06cc\u0644 \u062f\u0642\u06cc\u0642 \u0647\u0632\u06cc\u0646\u0647 \u06a9\u0644 \u0645\u0627\u0644\u06a9\u06cc\u062a (TCO) \u0631\u0627 \u0627\u0631\u0627\u0626\u0647 \u0645\u06cc\u200c\u062f\u0647\u06cc\u0645.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"><a style=\"display: inline-block; padding: 16px 40px; background: #ff6b35; color: #ffffff; text-decoration: none; border-radius: 4px; font-weight: bold; font-size: 1.1rem; transition: opacity 0.3s;\" href=\"mailto:sales@n2-compressor.com\">\u062f\u0631\u062e\u0648\u0627\u0633\u062a \u067e\u06cc\u0634\u0646\u0647\u0627\u062f \u0641\u0646\u06cc<\/a><br \/>\n<a style=\"display: inline-block; padding: 16px 40px; background: transparent; color: #ff6b35; text-decoration: none; border-radius: 4px; font-weight: bold; font-size: 1.1rem; border: 2px solid #ff6b35; transition: all 0.3s;\" href=\"https:\/\/n2-compressor.com\/fa\/about\/\">\u062f\u0631\u0628\u0627\u0631\u0647 \u0627\u0648\u0631-\u067e\u0627\u0648\u0631<\/a><\/div>\n<p style=\"color: #8899aa; font-size: 0.9rem; margin: 20px 0 0;\">\u0627\u06cc\u0645\u06cc\u0644: <a style=\"color: #ff6b35; text-decoration: underline;\" href=\"mailto:sales@n2-compressor.com\">sales@n2-compressor.com<\/a> | \u067e\u0627\u0633\u062e \u0638\u0631\u0641 \u06f2\u06f4 \u0633\u0627\u0639\u062a<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u06a9\u0645\u067e\u0631\u0633\u0648\u0631 \u0646\u06cc\u062a\u0631\u0648\u0698\u0646 DW-120\/8 \u0628\u0627 \u0641\u0646\u0627\u0648\u0631\u06cc \u067e\u06cc\u0633\u062a\u0648\u0646 \u0628\u062f\u0648\u0646 \u0631\u0648\u063a\u0646\u060c 120 \u0645\u062a\u0631 \u0645\u06a9\u0639\u0628 \u062f\u0631 \u062f\u0642\u06cc\u0642\u0647 \u0628\u0627 \u0633\u0631\u0639\u062a 0.80 \u0645\u06af\u0627\u067e\u0627\u0633\u06a9\u0627\u0644 \u0627\u0631\u0627\u0626\u0647 \u0645\u06cc\u200c\u062f\u0647\u062f. \u0627\u06cc\u062f\u0647\u200c\u0622\u0644 \u0628\u0631\u0627\u06cc \u0648\u0627\u062d\u062f\u0647\u0627\u06cc \u062a\u0635\u0641\u06cc\u0647 \u0647\u0648\u0627\u06cc ASU \u062f\u0631 \u0645\u0642\u06cc\u0627\u0633 \u0628\u0632\u0631\u06af\u060c \u0648\u0627\u062d\u062f\u0647\u0627\u06cc \u062a\u0642\u0648\u06cc\u062a \u0641\u0634\u0627\u0631 VPSA \u0628\u0632\u0631\u06af \u0648 \u0645\u062c\u062a\u0645\u0639\u200c\u0647\u0627\u06cc \u067e\u062a\u0631\u0648\u0634\u06cc\u0645\u06cc \u06cc\u06a9\u067e\u0627\u0631\u0686\u0647. \u0647\u0645\u06cc\u0646 \u0627\u0645\u0631\u0648\u0632 \u062f\u0631\u062e\u0648\u0627\u0633\u062a \u0642\u06cc\u0645\u062a \u062f\u0647\u06cc\u062f.<\/p>","protected":false},"featured_media":360,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1121],"product_tag":[],"class_list":["post-559","product","type-product","status-publish","has-post-thumbnail","product_cat-dw-series-nitrogen-compressor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/product\/559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/comments?post=559"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/media\/360"}],"wp:attachment":[{"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/media?parent=559"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/product_brand?post=559"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/product_cat?post=559"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/n2-compressor.com\/fa\/wp-json\/wp\/v2\/product_tag?post=559"}],"curies":[{"name":"\u0648\u0631\u062f\u067e\u0631\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}