ضاغط النيتروجين ZW-4/8 - معزز نيتروجين دقيق خالٍ من الزيت لتطبيقات الضغط العالي صغيرة الحجم

الوصف

ضاغط النيتروجين ZW-4/8 - معزز نيتروجين دقيق خالٍ من الزيت لتطبيقات الضغط العالي صغيرة الحجم

Delivering 4 m³/min at 0.80 MPa discharge pressure, the ZW-4/8 is a two-stage, two-row oil-free piston nitrogen compressor engineered for high-pressure laboratory supply, precision instrument inerting, and compact industrial nitrogen boosting where elevated pressure and absolute purity are non-negotiable.

ZW-4/8 nitrogen compressor high pressure oil-free precision unit

نظرة عامة على المنتج

ال ZW-4/8 nitrogen compressor is a precision-engineered oil-free piston compressor designed for applications where high discharge pressure and compact footprint must coexist. With a rated capacity of 4 m³/min and an elevated discharge pressure of 0.80 MPa, this unit addresses the demanding requirements of high-pressure nitrogen distribution in laboratory complexes, precision manufacturing facilities, and small-scale industrial processes.

Unlike conventional compressors that compromise on either pressure capability or purity, the ZW-4/8 achieves both through a آلية ضغط خالية تمامًا من الزيت. The piston rings and rider bands are manufactured from advanced self-lubricating PTFE composites that operate without hydrocarbon lubricants, ensuring the nitrogen stream remains completely free of oil contamination. This native oil-free characteristic is essential for applications such as GC-MS carrier gas supply, pharmaceutical sterile processing, and semiconductor wafer handling where even trace oil vapor can compromise product integrity.

ال two-stage, two-row (二列二级) architecture is specifically optimized for the 0.80 MPa discharge pressure target. By distributing the pressure ratio across two compression stages with inter-stage cooling, the ZW-4/8 maintains discharge temperatures within safe limits while achieving the higher pressure output that single-stage designs cannot reach. The compact dimensions of 2250 × 1296 × 2200 mm and a weight of just 2.00 tonnes make this unit suitable for installation in confined machinery rooms, mobile skids, and containerized nitrogen supply systems.

ZW series nitrogen compressor compact high pressure two stage design

Technical Specifications – ZW-4/8

المعلمة قيمة وحدة
نموذج ZW-4/8
نمط مرحلتين، صفين (二列二级)
سعة 4 م³/دقيقة
ضغط التفريغ 0.80 ميجا باسكال
حجم الضاغط (الطول × العرض × الارتفاع) 2250 × 1296 × 2200 مم
وزن 2.00 ت
قوة 30 كيلوواط
الجهد االكهربى 380 V
وسط غازي النيتروجين (N₂)
تشحيم خالٍ من الزيوت

* جميع المواصفات مصنفة وفقًا لظروف مرجعية قياسية (ISO 1217، الملحق ج). قد يختلف الأداء الفعلي بناءً على ارتفاع الموقع ودرجة الحرارة المحيطة وظروف المدخل.

الميزات الرئيسية والمزايا الهندسية

1. High-Pressure Oil-Free Piston Technology

The ZW-4/8 employs a مجموعة حلقات المكبس ذاتية التشحيم وحزام التثبيت fabricated from high-density PTFE composites reinforced with glass fiber and bronze particulates. These rings achieve a coefficient of friction below 0.08 without any external lubrication, delivering محتوى الزيت من الفئة 0 وفقًا للمعيار ISO 8573-1 certification in the compressed nitrogen stream. This is particularly critical for high-pressure applications where oil contamination would be amplified by the pressure ratio, making downstream oil removal exponentially more difficult and expensive.

2. Two-Stage Compression for Elevated Pressure Ratios

ال تصميم معماري من مرحلتين وصفين is thermodynamically essential for achieving the 0.80 MPa discharge pressure from typical nitrogen generator outlet pressures of 0.05–0.10 MPa. The first-stage cylinder compresses the nitrogen to an intermediate pressure of approximately 0.25–0.30 MPa, after which an inter-stage cooler removes the heat of compression. The second-stage cylinder then raises the pressure to the final 0.80 MPa target. This staged approach limits the discharge temperature of each stage to below 160°C, preventing thermal degradation of the PTFE sealing elements and maintaining valve plate integrity under the elevated pressure duty.

3. Compact Footprint with High Power Density

في 2250 × 1296 × 2200 mm, the ZW-4/8 occupies less than 3 m² of floor space while delivering 0.80 MPa discharge pressure—a combination that is difficult to achieve with alternative compressor technologies. The compact vertical crankcase design minimizes the longitudinal footprint while providing adequate access for routine maintenance. The 2.00-tonne weight permits transportation and positioning using standard forklift equipment, making the ZW-4/8 suitable for retrofit installations in existing machinery rooms, mobile nitrogen supply skids, and containerized process units.

4. Efficient 380V Motor Drive

The ZW-4/8 is driven by a 30 kW, 380V, 50Hz three-phase induction motor conforming to IEC 60034-1 IE3 efficiency class. The standard low-voltage configuration integrates directly into existing 380V industrial distribution panels without requiring specialized medium-voltage infrastructure. This electrical simplicity is particularly valuable for small-scale facilities, laboratories, and mobile installations where medium-voltage switchgear would be prohibitively expensive. The 30 kW power rating provides an excellent balance between compression capability and electrical demand, keeping operating costs manageable for intermittent-duty applications.

ZW-4/8 nitrogen compressor general assembly compact high pressure design

سيناريوهات التطبيق

High-Pressure Laboratory Nitrogen Supply

Research laboratories and analytical facilities require high-pressure nitrogen for gas chromatography carrier gas, mass spectrometry nebulizer gas, and inert atmosphere glove box supply. The ZW-4/8’s 0.80 MPa discharge pressure is sufficient to feed high-pressure nitrogen regulators and distribution manifolds serving multiple instruments simultaneously. The oil-free certification ensures that the nitrogen stream meets the stringent purity requirements of analytical instruments without requiring additional purification cartridges or oil-monitoring instrumentation. The 4 m³/min capacity can comfortably support 8–12 GC-MS systems or 4–6 ICP-MS instruments operating in parallel.

ZW-4/8 nitrogen compressor high pressure laboratory supply application

Precision Manufacturing & Semiconductor Inerting

In electronics and semiconductor manufacturing, nitrogen is used for wafer handling inerting, reflow oven atmosphere control, and component storage dry cabinets. The ZW-4/8 high-pressure nitrogen compressor delivers the 0.80 MPa pressure required for precision pressure regulators that maintain sub-atmosphere inert environments in glove boxes and wafer transfer chambers. The oil-free design is absolutely critical in these applications because even nanogram-level oil contamination can cause solder joint defects, conformal coating adhesion failures, and contamination of optical surfaces on precision components.

Pharmaceutical Sterile Processing & Aseptic Filling

Pharmaceutical manufacturing facilities use high-pressure nitrogen for aseptic filling line inerting, vial headspace displacement, and freeze-dryer chamber purging. The ZW-4/8’s 0.80 MPa discharge pressure provides the head necessary to feed nitrogen through HEPA-filtered distribution systems and precision pressure regulators that maintain sterile barrier pressures in isolators and restricted access barrier systems (RABS). The oil-free certification ensures compliance with FDA 21 CFR 211.72 (equipment construction) and EU GMP Annex 1 (sterile medicinal products) without requiring additional oil-removal validation.

ZW-4/8 nitrogen compressor pharmaceutical sterile processing application

Small-Scale VPSA Nitrogen Booster

For compact VPSA nitrogen generators producing 99.5–99.9% purity nitrogen at near-atmospheric pressure, the ZW-4/8 compresses the low-pressure product to 0.80 MPa for high-pressure distribution. The compact footprint allows the compressor to be mounted on the same skid as the VPSA generator, creating an integrated nitrogen supply system that occupies minimal floor space. The oil-free compression path protects the carbon molecular sieve from hydrocarbon poisoning, preserving the generator’s separation efficiency and extending adsorbent life by preventing irreversible contamination.

المواد والإنشاءات

The ZW-4/8 is constructed from materials selected for high-pressure nitrogen compatibility, corrosion resistance, and long-term mechanical reliability:

عنصر مادة مواصفة
كتلة الأسطوانات حديد الزهر الرمادي GG25 / HT250، ممرات تبريد متكاملة
عمود المرفق فولاذ سبيكي مطروق 42CrMo4, Q&T, ISO 1940 G2.5 balanced
حلقات المكبس مركب من البرونز والزجاج وPTFE Self-lubricating, oil-free rated
أساور رايدر مركب PTFE توجيه المكبس، مقاومة الاحتكاك
صفائح الصمامات الفولاذ المقاوم للصدأ SS316, concentric ring spring design
مبرد داخلي غلاف من الفولاذ الكربوني / أنابيب من الفولاذ المقاوم للصدأ 304 Compact shell-and-tube, 1.5× hydrotest
مبرد لاحق غلاف من الفولاذ الكربوني / أنابيب من الفولاذ المقاوم للصدأ 304 Finned tube design, 32°C cooling water
الإطار الأساسي الفولاذ الإنشائي Welded, vibration-damped mounting

تم تصميم وتصنيع جميع المكونات التي تتحمل الضغط وفقًا لـ ASME BPVC القسم الثامن القسم 1 or Chinese GB 150 standards. Weld joints undergo 100% radiographic inspection (RT), and each pressure vessel is subjected to hydrostatic testing at 1.5× the maximum allowable working pressure (MAWP) for a minimum hold time of 30 minutes.

ZW-4/8 nitrogen compressor factory precision machining quality control

إرشادات التركيب والصيانة

المتطلبات الأساسية والمكانية

The ZW-4/8 weighs 2.00 tonnes and features a low center of gravity due to its compact vertical design. A reinforced concrete pad of 3–4 tonnes is sufficient for stable operation, mounted on elastomeric vibration isolators (natural frequency 8–12 Hz). The two-row opposed-cylinder arrangement inherently cancels first-order inertial forces, minimizing vibration transmission to sensitive laboratory equipment or precision manufacturing machinery nearby. Required clearances: 1.0 m on the non-drive side for valve maintenance, 0.8 m on the drive side for motor access, and 1.5 m overhead for routine service.

مواصفات مياه التبريد

يبلغ الطلب على مياه التبريد ما يقارب 8 m³/h at an inlet temperature not exceeding 32°C. The water distribution circuit feeds the cylinder jackets and intercooler in parallel. Acceptable water quality: pH 6.5–8.5, total hardness < 300 mg/L as CaCO₃, chloride < 50 mg/L, suspended solids < 30 mg/L. For laboratory installations without dedicated cooling water infrastructure, a compact air-cooled aftercooler option is available, eliminating the need for water supply entirely.

جدول الصيانة الوقائية

فاصلة بند الخدمة الإجراء المطلوب
يوميًا الفحص البصري والتشغيلي Inspect for leaks, abnormal noise, cooling water flow
250 ساعة فحص صفيحة الصمام تحقق من وجود رواسب كربونية، أو إجهاد في النوابض، أو تشققات في الصفائح.
1000 ساعة تقييم تآكل حلقات المكبس Measure groove clearance; replace if > 0.20 mm
4000 ساعة خدمة وسيطة استبدل حلقات المكبس، وأشرطة التوجيه، ومجموعات الصمامات.
8000 ساعة إصلاح شامل رئيسي افحص عمود المرفق، وقم بقياس خلوص المحامل، واستبدل الأجزاء حسب الحاجة.

The oil-free design of the ZW-4/8 dramatically reduces maintenance complexity compared to lubricated alternatives. There are no oil changes to schedule, no oil samples to analyze, no filter elements to replace, and no oil separator cartridges to monitor. The only consumable wear items are the حلقات مكابس PTFE وأحزمة تثبيت, which typically achieve 4,000–6,000 hours of service under clean nitrogen conditions.

ZW-4/8 nitrogen compressor workshop assembly and quality inspection

شهادات الامتثال والسلامة

The ZW-4/8 nitrogen compressor meets or exceeds the following international standards and regulatory requirements:

معدات الضغط
ASME BPVC القسم الثامن Div.1، GB 150-2011، PED 2014/68/EU الوحدة A
السلامة الكهربائية والميكانيكية
IEC 60034-1 (كفاءة IE3)، IEC 60204-1، ISO 12100
شهادة خلو المنتج من الزيوت
ISO 8573-1 Class 0 (Oil Content), TÜV Rheinland independently tested
الجودة والبيئة
ISO 9001:2015، ISO 14001:2015

⚠️ تنبيه أمني

Nitrogen is an odorless, colorless asphyxiant gas. All ZW-4/8 installations must include continuous oxygen monitoring in the compressor room and adjacent areas. Ventilation must maintain ambient oxygen above 19.5% per OSHA 29 CFR 1910.146. Alarm interlocks should trigger at 19.5% O₂ and hard shutdown at 18.0% O₂. Personnel entry into enclosed compressor rooms requires portable oxygen monitors and a buddy system. High-pressure nitrogen systems must be equipped with pressure relief devices rated to ASME BPVC Section VIII requirements.

ZW-4/8 nitrogen compressor ISO certification and compliance documentation

تحليل الأداء والكفاءة

The ZW-4/8 achieves a specific power consumption of approximately 7.50 kW per m³/min of nitrogen at 0.80 MPa discharge pressure. While this specific power is higher than our larger LW-series models due to the reduced scale efficiency inherent in small-capacity compressors, it remains competitive within the sub-5 m³/min high-pressure oil-free piston segment. For comparison, oil-lubricated screw compressors in this pressure and size range typically consume 8.0–9.5 kW/m³/min, and diaphragm compressors (often selected for oil-free high-pressure duty) can exceed 12 kW/m³/min.

Over an 8,000-hour annual operating cycle, the ZW-4/8’s efficiency advantage versus less efficient alternatives yields approximately 12,000–32,000 kWh of energy savings per year. At $0.08/kWh, this represents $960–$2,560 in annual electricity cost reduction. However, the primary economic driver for ZW-4/8 selection is typically the التخلص من المواد الاستهلاكية المتعلقة بالنفط ومعدات التنقية اللاحقة rather than marginal energy savings.

ال التكلفة الإجمالية لامتلاك نظام ضغط النيتروجين عالي الضغط in small-scale applications is dominated by maintenance labor and consumables. The ZW-4/8’s oil-free design eliminates oil changes ($300–600/year), filter replacements ($150–300/year), separator cartridge changes ($400–800/year), and oil analysis ($100–200/year), delivering total consumable savings of $950–$1,900 annually compared to lubricated alternatives. Additionally, the elimination of downstream oil-removal equipment (coalescing filters, activated carbon adsorbers, oil monitors) saves $3,000–$8,000 in capital expenditure.

إمكانيات التخصيص وتصنيع المعدات الأصلية

We provide flexible customization options to adapt the ZW-4/8 to specific installation constraints and end-user requirements:

  • حزم مثبتة على قاعدة انزلاقية: ضاغط ومحرك ومبرد ولوحة تحكم مُجمّعة مسبقًا على قاعدة فولاذية هيكلية مزودة بفتحات للرافعة الشوكية وحلقات رفع. يقلل ذلك من عملية التركيب الميداني إلى مجرد توصيل كهربائي وتوصيل مياه التبريد.
  • وحدات المقطورات المتنقلة: The ZW-4/8 can be mounted on a road-legal trailer with integrated diesel generator, cooling system, and nitrogen storage, creating a fully mobile high-pressure nitrogen supply unit for construction sites, pipeline maintenance, and emergency response.
  • Air-Cooled Configuration: Optional air-cooled aftercooler eliminates the need for cooling water supply, making the ZW-4/8 suitable for laboratory installations without plumbing infrastructure or mobile applications where water availability is limited.
  • نظام التحكم المنطقي القابل للبرمجة والمراقبة عن بعد: Optional Siemens LOGO! or S7-1200 PLC with 7-inch HMI touchscreen, Ethernet connectivity, and SMS/email alarm notifications. Compatible with Modbus TCP/IP for SCADA integration.
  • حاويات عازلة للصوت: Compact IP54-rated sound enclosure reducing noise from 82 dB(A) to 66 dB(A) at 1 meter, suitable for indoor installations in noise-sensitive environments such as laboratories and office-adjacent machinery rooms.
  • تصنيع المعدات الأصلية والعلامات التجارية الخاصة: أنظمة طلاء مخصصة، ولوحات تحمل علامات تجارية، وحزم وثائق محلية لموزعي معدات الغاز ومكاملين الأنظمة.

تتوفر التكوينات المخصصة من الحد الأدنى للطلب: وحدة واحدةتُسلّم المقترحات الهندسية عادةً خلال 3-5 أيام عمل. مدة التسليم القياسية هي 10-12 أسبوعًا؛ ويتوفر التسليم السريع خلال 8 أسابيع للطلبات المؤهلة.

ZW-4/8 nitrogen compressor custom skid mounted installation site

Case Study: Pharmaceutical Aseptic Filling Line Nitrogen Upgrade

عميل: A pharmaceutical manufacturing facility in Thailand specializing in sterile injectable products

تحدي: The facility was using a lubricated reciprocating nitrogen compressor to supply high-pressure nitrogen (0.70 MPa) to their aseptic filling lines. Oil contamination in the nitrogen stream was detected at 1.5 mg/m³, exceeding the 0.1 mg/m³ limit specified in their product quality agreement with international buyers. The oil was also causing frequent clogging of the 0.22 μm absolute filters in the nitrogen distribution system, requiring filter replacement every 3 weeks instead of the designed 6-month interval.

حل: لقد قمنا بتوريد ZW-4/8 oil-free nitrogen compressor as a direct replacement, configured on a custom skid with an air-cooled aftercooler (eliminating cooling water requirements), a Siemens LOGO! PLC control panel, and an integrated 0.5 m³ surge vessel. The skid footprint was designed to fit into the existing compressor room without civil modifications. The 0.80 MPa discharge pressure provided a safety margin above the 0.70 MPa required by the filling line regulators.

Results After 24 Months:

  • Nitrogen oil content: Reduced from 1.5 mg/m³ to <0.01 mg/m³, achieving ISO 8573-1 Class 0 certification
  • Absolute filter replacement interval: Extended from 3 weeks to 8 months, saving $18,000/year in filter costs and reducing production downtime
  • Overall maintenance expenditure: Decreased by 45% due to elimination of oil changes, filter replacements, and separator overhauls
  • Product quality complaints: Zero oil-related rejections since commissioning, preserving international buyer contracts
  • توقف غير مخطط له: Zero events in 24 months of continuous operation

“The ZW-4/8 compressor solved our oil contamination problem permanently. Our filter replacement costs dropped by 85%, and we have not had a single quality rejection related to nitrogen purity since installation. The air-cooled option was a bonus—no cooling water meant one less utility to worry about.” — Quality Assurance Manager, Pharmaceutical Manufacturing Facility

ZW-4/8 nitrogen compressor pharmaceutical installation case study site

الأسئلة الشائعة ودليل الاختيار

What is the expected service life of the ZW-4/8?

The ZW-4/8 is engineered for a الحد الأدنى للعمر التصميمي 15 عامًا (approximately 120,000 operating hours) in clean nitrogen service. The cast-iron frame and forged steel crankshaft are rated for the full design life. PTFE piston rings and rider bands are the primary wear items, with replacement intervals of 4,000–6,000 hours. Valve plate assemblies typically last 2,500–4,000 hours before requiring refurbishment.

Can the ZW-4/8 operate from a VPSA nitrogen generator with pulsating outlet pressure?

Yes. The ZW-4/8 can accommodate inlet pressure variations from 0.03 MPa to 0.12 MPa. For VPSA applications with significant pressure pulsation, we recommend installing a 0.5–1.0 m³ surge vessel upstream of the compressor suction to dampen cyclic fluctuations and protect the valves from hydraulic shock. An optional pulsation dampener can be fitted for severe pulsation conditions.

Is the ZW-4/8 suitable for outdoor installation?

The standard ZW-4/8 is designed for تركيب داخلي في غرفة آلات جيدة التهوية. للاستخدام الخارجي، نقدم خيارًا إضافيًا. غلاف مقاوم للعوامل الجوية بمعيار IP54 مع توفير التدفئة (للمناطق ذات درجة حرارة -20 درجة مئوية)، والواقيات الشمسية (للمناطق ذات درجة حرارة محيطة 55 درجة مئوية)، والتهوية القسرية. يُنصح باستخدام خيار الغلاف الصوتي للتركيبات الخارجية لضمان الالتزام بمعايير الضوضاء.

How does the ZW-4/8 compare to oil-lubricated alternatives for high-pressure nitrogen compression?

Oil-lubricated screw compressors offer higher capacity density but introduce unacceptable oil contamination risk for pharmaceutical, food-grade, and electronics applications. The ZW-4/8 achieves ISO 8573-1 Class 0 natively without downstream filtration. At high pressure ratios (8:1 to 16:1), piston compressors also demonstrate superior efficiency compared to screw compressors, which are optimized for lower pressure ratios. For a comprehensive TCO comparison, see our تحليل عائد الاستثمار لضاغط النيتروجين.

When should I avoid selecting the ZW-4/8?

The ZW-4/8 is NOT recommended for: (1) Discharge pressures above 1.00 MPa—consider our DW series or ZW multi-stage models for higher pressure requirements; (2) Capacity requirements above 8 m³/min—larger ZW-8/6 or LW-series models offer better scale efficiency; (3) تعديل التدفق المستمر أقل من 45% من السعة المقدرة—piston compressors are less efficient at deep turndown; a dual-unit arrangement or VFD-equipped alternative may be preferable for highly variable demand.

المنتجات والحلول ذات الصلة

ZW-8/6 Compact Nitrogen Compressor

Higher capacity (8 m³/min) at 0.60 MPa for small-scale industrial nitrogen boosting, VPSA booster stations, and laboratory supply. Same compact footprint with doubled flow capacity.

Explore ZW-8/6 →

ضواغط النيتروجين عالية الضغط من سلسلة DW

ضواغط خالية من الزيت متوسطة إلى عالية الضغط (0.40-2.00 ميجا باسكال) لحقن النيتروجين، وتعزيز خطوط الأنابيب، والتخليق الكيميائي. سعات من 2 إلى 130 متر مكعب/دقيقة.

استكشف سلسلة DW →

ضواغط النيتروجين ذات السعة الكبيرة من سلسلة LW

ضواغط مكبسية عالية التدفق وخالية من الزيت (20-130 م³/دقيقة) لتوفير الطاقة الاحتياطية لوحدات فصل الهواء المبردة، وتعزيز ضغط الهواء المتغير الضغط، وتوزيع خطوط الأنابيب الصناعية. ضغوط التفريغ من 0.30 إلى 0.80 ميجا باسكال.

استكشف سلسلة LW →

للحصول على نظرة عامة شاملة على ضاغط نيتروجين صناعي للاطلاع على محفظتنا، بما في ذلك ضواغط الأكسجين الخالية من الزيت، وضواغط الهيدروجين، وحلول الغازات المتخصصة، يرجى الاتصال بفريقنا الهندسي أو تصفح الكتالوج الإلكتروني الخاص بنا.

Ready to Upgrade Your High-Pressure Nitrogen Supply?

Our application engineers are available to evaluate your nitrogen flow requirements, inlet conditions, discharge pressure targets, and integration constraints. We provide complimentary technical proposals, layout drawings, piping and instrumentation diagrams (P&IDs), and detailed TCO analyses within 48 hours.

بريد إلكتروني: [email protected] الرد خلال 24 ساعة